Thursday, February 28, 2013

Q'Mark Artisan Wall Heater

Artisan SmartSeries®-Architectural Digital Wall Heater by Q'Mark, Marley and Anderson-Bolds

The new standard in Wall Heaters.  The Q'Mark SSAR wall heaters.
Programable, stylish, and Energy Efficient.





Q'Mark Artisan SmartSeries® - In a class above the competition – No other heater in the market comes close to the unique styling of the Q'Mark Artisan SmartSeries®.


  • The best in contemporary design matched with the latest Smart technologies - Touch-activated controls offer an ideal combination of sleek styling and ease of operation.
  • Heat where you are, not where you aren’t . Instant response when you want it. Save energy by heating only the areas you occupy.
  • Precise heat within 1.5 degree of set temperature (as compared to five degrees with conventional bi-metal thermostats).
  • 5 day / 2 day programmability (5 weekdays and 2 day weekend, 4 program periods per day).
  • SmartSeries provides only the amount of heat needed at any given moment by continually calculating heat output and fan speed of the proportional difference between room temperature and the set temperature.
  • Built-in fan delay operates when unit is turned off after heating to prolong element life. Fan delay also prevents fan from coming on until element has warmed up.
  • Fan only mode (no heat) for supplemental ventilation.
  • BMS feature allows connection to Building Management Systems (Dry contact).
  • Heater can be locked out for security so settings cannot be changed.
  • Easy to use touch screen operation with adjustable soft signal beeps.
  • Hold mode maintains constant set temperature which can be used for freeze protection or vacation setting for when you are not there.
  • Quick set up – ‘right out of the box’ - 3 piece construction – Includes back box, Element/Fan Deck and Grille.



CATALOG NUMBERVOLTSWATTSAMPSBTUHRWEIGHT
SSAR1802120540 - 1800156,14226
SSAR48082081800 - 480023.116,37826
SSAR48042401800 - 480020.016,37826
SSAR48072771800 - 480017.316,37826




MOUNTING LIMITATIONS
do not install heater closer than 12” to the floor, 12” to an adjacent wall, 36” to the ceiling. do not install heater behind towel rack or door, upside down or sideways, in the floor, in the ceiling, or in closets.






www.anderson-bolds.com
qmark@anderson-bolds.com
216-360-9800
Heating Form

Sunday, February 10, 2013

ERDCO series 3200 See-Flo Indicator

Anderson-Bolds and ERDCO Flow Meters

ERDCO 3200 See-Flo® Indicator

See-Flo® meters indicate flow rate and permit visual inspection of water, air or other transparent fluids. For general purpose industrial service, See-Flo® meters handle a wide range of process fluids in vertical or horizontal piping runs.

The wedge shape of the meter housing makes See-Flo® practically self-cleaning. Where periodic maintenance might be necessary, the tempered glass window is easily removed and replaced. Because of its large internal cavities this product will not plug up like the old glass tube "rotameters".
Each flowmeter is calibrated to be direct reading for the liquid or gas operating conditions that you specify. Scales with special engineering units and dual units of measure are available.
PLEASE NOTE THE THE SEE_FLO METER NEEDS TO BE ORDERED BASED ON DIRECTION OF FLOW.  Right to Left, Left to Right, Up or Down. The meter will not work properly if ordered incorrectly. Please specify when ordering.
Applications: Transparent Liquid or Gases
Functions: Direct Reading flow rate and Observe fluid condition
Features: Lowest Cost Meter; No power required; Calibrated for application conditions
Materials: Aluminum, brass or 316 stainless steel
Pressure Limit:  200 psig
Temperature Limit: 400ºF (400 requires Viton or EPM O-rings)
Pipe Sizes: 1/2 to 12 inches

Ideal for use with water containing solid particles (up to 1/4" dia.) that clog conventional meters, these flowmeters have a 17-7 PH stainless steel vane inside the flowmeter that moves in proportion to flow rate. There are no floats that could stick and no tubes to clean. Scale is graduated in gallons per minute. Flowmeters have a brass body (unless noted) and EPDM O-rings. Maximum pressure is 200 psi at 70° F. Temperature range is -10° to +400° F. 

Below are common Flow meters, but ERDCO and Anderson-Bolds can do many combinations of size, flow, body material, seal material and flow direction.

Flow Range (gpm)
SIZE
MC   p/n
ERDCO p/n
0.5 – 5 gpm
½”
4165K112
1 - 10 gpm
½”
4165K122
3221-02T0-11 / 1-10
1.5 – 15 gpm
¾”
4165K132
3221-03T0-11 / 1.5-15
2 – 20 gpm
1”
4165K142
3221-04T0-11 / 2-20
5 – 50 gpm
1”
4165K152
15 – 150 gpm
1-1/2”
4165K162
3221-06T0-11 / 15-150
25 – 250 gpm
2”
4165K172
3221-08T0-11 / 25-250
30 – 300 gpm
3”
4165K182
HORIZONTAL
LEFT  to
RIGHT
DIRECTION


Flow Range (gpm)
SIZE
MC   p/n
ERDCO p/n
0.5 – 5 gpm
½”
4165K113
 3222-02T0-11 / .5-5
1 - 10 gpm
½”
4165K123
 3222-02T0-11 / 1-10
1.5 – 15 gpm
¾”
4165K133
2 – 20 gpm
1”
4165K143
 3222-04T0-11 / 2-20
5 – 50 gpm
1”
4165K153
 3222-04T0-11 / 5-50
15 – 150 gpm
1-1/2”
4165K163
 3222-06T5-11 /15-150
25 – 250 gpm
2”
4165K173
 3222-08T5-11 /25-250
30 – 300 gpm
3”
4165K183
 3222-12T5-11 /30-300
HORIZONTAL
RIGHT  to 
LEFT       FLOW
DIRECTION


Flow Range (gpm)
SIZE
MC   p/n
ERDCO p/n
0.5 – 5 gpm
½”
4165K114
3223-02T0-11 / .5-5
1 - 10 gpm
½”
4165K124
3223-02T0-11 / 1-10
1.5 – 15 gpm
¾”
4165K134
3223-03T0-11 / 1.5-15
2 – 20 gpm
1”
4165K144
3223-04T0-11 / 2-20
5 – 50 gpm
1”
4165K154
15 – 150 gpm
1-1/2”
4165K164
3223-06T5-11 / 15-150
25 – 250 gpm
2”
4165K174
3223-08T5-11 / 25-250
30 – 300 gpm
3”
4165K184
VERTICAL
UP é
FLOW
DIRECTION


Flow Range (gpm)
SIZE
MC   p/n
ERDCO p/n
0.5 – 5 gpm
½”
4165K115
3224-02T011 / .5-5
1 - 10 gpm
½”
4165K125
3224-02T011 / 1-10
1.5 – 15 gpm
¾”
4165K135
3224-03T011 / 1.5-15
2 – 20 gpm
1”
4165K145
3224-04T011 / 2-20
5 – 50 gpm
1”
4165K155
3224-04T011 / 5-50
15 – 150 gpm
1-1/2”
4165K165
3224-06T011 / 15-150
25 – 250 gpm
2”
4165K175
30 – 300 gpm
3”
4165K185
3224-12T011 / 30-300
VERTICAL
DOWN ê
FLOW
DIRECTION


Please note,  SEE-FLO METERS can come in gpm ranges specified to your specific application.

Also the connection type can be any of the following:

NPT END
NPT BACK
TRI-CLAMP
GROOVED
BEVELED
SOCKET (1/2 - 1 inch)
FLANGE (150#RF)
FLANGE (150#FF)
FLANGE (300#RF)
FLANGE (300#FF)
FLANGE (DIN PN16)
BSPT End
BSPT Back


ERDCO®  ENGINEERING  COMPANY offers a complete line of flowmeters, sight flow indicators, flow transmitters and flow indicating switches. We employ elegantly simple measuring technologies with proven reliability in utility fluid applications.
Whether it's chilled water, air, nitrogen, steam, lube oil or other process support fluid, ERDCO has the flow measurement solution. Select from in-line and insertion styles that feature simplicity, rugged construction and reliable operation. This product range has great versatility across a broad set of applications.


Contact Anderson-Bolds at 216-360-9800 or via our CONTACT FORM
Ask for Jerry for your ERDCO Flow Meter needs and questions.
ERDCO Meters On Anderson-Bolds