Showing posts with label meter. Show all posts
Showing posts with label meter. Show all posts

Monday, April 29, 2019

ATC Diversified Multifunction Meter VCFP96M

Anderson-Bolds sells the Diversified Electronics Electric Meter for Industry

Diversified Electronics Industrial Controls - Go Orange


To get a quote use our ATC/Diversified Parts Form HERE!

Diversified Electronics, Orange Controls for automation.

The VCFP96M is a complete single phase and three phase digital metering system suitable for low, medium and high voltage control panels, gensets, load banks, building management systems and power management systems. The VCFP96M can be used on single phase, three phase three wire as well as three phase four wire balanced or unbalanced systems. The six easy to access front control keys are used for scrolling up or down through the parameters being measured and displayed such as voltage, current, power factor, power (active, reactive, apparent), energy and frequency. Output specifications include pulse output and RS485 Modbus RTU communication protocol compatible with PC, PLC, RTU, data loggers and SCADA programs. The VCFP96M is available in a 96 x 96 mm panel mount housing (front panel IP65) with red led display for easy viewing in a variety of conditions.

BUY THE VCFP96M METER HERE:

VIEW THE DATA SHEET HERE.

ATC Diversified VCFP96M UL Listed Meter













Input Specifications


Electrical Connection
3Ø - 3 wire, 3Ø - 4 wire, 2Ø - 3 wire, 1Ø - 2 wire
Input Voltage Range
11 to 300V AC, (Phase to Neutral) 19 to 519V AC (Phase to Phase)
Input Current Range
Nominal 5A AC (Min-11mA, Max-6A)
Frequency
45 to 65Hz
Display Scrolling 
Automatic / Manual (Programmable) 
Power Consumption
8VA Max
Display Reset 
Programmable (For energy)
Resolution
For energy :0.01k, 0.1k, 1k, 0.01m, 0.1m, 1m (depending upon CT ratio x PT ratio)For Power, Voltage, Current : Auto resolutionFor Power factor : 0.001
Accuracy
Voltage (L-N / L-L) : ±0.5% of F.S. Power Factor ±0.01 Current ±0.5% F.S.Frequency : ±0.1% For L-N Voltage >20VFor L-L Voltage >35VPower (Active, Reactive, Apparent) : 1%Energy (Active, Reactive, Apparent) : Class 1
Memory Retention
10 years (For energy) 
Measuring Parameters

Voltage (L-L / L-N) (Individual / Average), Current (I1, I2, I3) (Individual / Average),Frequency, Power Factor (Individual /Total), Active, Reactive & Apparent power (Individual / Total),Active, Reactive & Apparent Energy (Total), Demand (Min / Max Active Power, Min/Max Reactive Power, Max Apparent Power), %THD up to 31st Level Max Demand Current, Neutral Current, Phase Sequence Detection

Output Specifications


Pulse Output
Voltage Range : External 24V DC maxCurrent Capacity : 100mA maxPulse Width : 100 ms ± 5 ms
CommunicationInterface and Protocol
RS485 and MODBUS RTU
Communication Address
1 to 255
Transmission Mode
Half duplex
Transmission Distance
500 meter maximum
Transmission Speed
300, 600, 1200, 2400, 4800, 9600, 19200 (in bps)
Parity
None, Odd, Even 
Stop Bits
1 or 2
Response Time
100 ms (max and independent of baud rate)

FEATURES:
• 3Ø True RMS (Voltage, Current)
• 3Ø Power (Active, Reactive, Apparent), Energy (Active, Reactive, Apparent)
• Programmable CT/PT Primary/Secondary
• CT Polarity Error Detection
• Variable Pulse width Selection
• Single Phase Network with Phase Selection
• Modbus RTU Communication (RS485)
• Neutral Current Measurement
• THD Up to 31st Level.
• Single Pulse Output / Demand Phase Sequence Detection

Compliance:

ESD Immunity
IEC 61000-4-2
 Level IV (Air discharge : 15kV),(Contact Discharge : -8kV
Surge Immunity
IEC 61000-4-5
+/- 2kV common mode, (Line to ground)+/- 1kV differential mode, (Line to Line)
Radiated Susceptibility
IEC 61000-4-3
Level III, 80 to 1000MHz (10V/m)Level II, 1.4GHz to 2GHz (3V/m)Level I, 2GHz to 2.7GHz (1V/m)
Conducted Susceptibility
IEC 61000-4-6
Level II (3V/m)
Voltage Dips and Interruptions
IEC 61000-4-11
Dips : 0% residual voltage / 1 cycle (Criteria B), 40% residual voltage / 10 cycles 50Hz / 12 cycles 60Hz (Criteria C)70% residual voltage / 25 cycles50Hz / 30 cycles 60Hz (Criteria C)Interruptions : 0% residual voltage /250 cycles 50Hz / 300 cycles 60Hz(Criteria C)
Conducted Emission
CISPR-11
Radiated Emission
CISPR-11
Electrical Fast Transient
IEC 61000-4-4
Level III (2kV)


Anderson-Bolds
216-360-9800
www.anderson-bolds.com

ATC / Diversified is a manufacturer of Industrial Automation Controls including Timers, Counters, Voltage Monitors, Current Monitors, Voltage Power Alerts, Time Delay Relays, Temperature Controls, Duplexors, Alternating Relays and Motor Protection.

Sunday, February 10, 2013

ERDCO series 3200 See-Flo Indicator

Anderson-Bolds and ERDCO Flow Meters

ERDCO 3200 See-Flo® Indicator

See-Flo® meters indicate flow rate and permit visual inspection of water, air or other transparent fluids. For general purpose industrial service, See-Flo® meters handle a wide range of process fluids in vertical or horizontal piping runs.

The wedge shape of the meter housing makes See-Flo® practically self-cleaning. Where periodic maintenance might be necessary, the tempered glass window is easily removed and replaced. Because of its large internal cavities this product will not plug up like the old glass tube "rotameters".
Each flowmeter is calibrated to be direct reading for the liquid or gas operating conditions that you specify. Scales with special engineering units and dual units of measure are available.
PLEASE NOTE THE THE SEE_FLO METER NEEDS TO BE ORDERED BASED ON DIRECTION OF FLOW.  Right to Left, Left to Right, Up or Down. The meter will not work properly if ordered incorrectly. Please specify when ordering.
Applications: Transparent Liquid or Gases
Functions: Direct Reading flow rate and Observe fluid condition
Features: Lowest Cost Meter; No power required; Calibrated for application conditions
Materials: Aluminum, brass or 316 stainless steel
Pressure Limit:  200 psig
Temperature Limit: 400ºF (400 requires Viton or EPM O-rings)
Pipe Sizes: 1/2 to 12 inches

Ideal for use with water containing solid particles (up to 1/4" dia.) that clog conventional meters, these flowmeters have a 17-7 PH stainless steel vane inside the flowmeter that moves in proportion to flow rate. There are no floats that could stick and no tubes to clean. Scale is graduated in gallons per minute. Flowmeters have a brass body (unless noted) and EPDM O-rings. Maximum pressure is 200 psi at 70° F. Temperature range is -10° to +400° F. 

Below are common Flow meters, but ERDCO and Anderson-Bolds can do many combinations of size, flow, body material, seal material and flow direction.

Flow Range (gpm)
SIZE
MC   p/n
ERDCO p/n
0.5 – 5 gpm
½”
4165K112
1 - 10 gpm
½”
4165K122
3221-02T0-11 / 1-10
1.5 – 15 gpm
¾”
4165K132
3221-03T0-11 / 1.5-15
2 – 20 gpm
1”
4165K142
3221-04T0-11 / 2-20
5 – 50 gpm
1”
4165K152
15 – 150 gpm
1-1/2”
4165K162
3221-06T0-11 / 15-150
25 – 250 gpm
2”
4165K172
3221-08T0-11 / 25-250
30 – 300 gpm
3”
4165K182
HORIZONTAL
LEFT  to
RIGHT
DIRECTION


Flow Range (gpm)
SIZE
MC   p/n
ERDCO p/n
0.5 – 5 gpm
½”
4165K113
 3222-02T0-11 / .5-5
1 - 10 gpm
½”
4165K123
 3222-02T0-11 / 1-10
1.5 – 15 gpm
¾”
4165K133
2 – 20 gpm
1”
4165K143
 3222-04T0-11 / 2-20
5 – 50 gpm
1”
4165K153
 3222-04T0-11 / 5-50
15 – 150 gpm
1-1/2”
4165K163
 3222-06T5-11 /15-150
25 – 250 gpm
2”
4165K173
 3222-08T5-11 /25-250
30 – 300 gpm
3”
4165K183
 3222-12T5-11 /30-300
HORIZONTAL
RIGHT  to 
LEFT       FLOW
DIRECTION


Flow Range (gpm)
SIZE
MC   p/n
ERDCO p/n
0.5 – 5 gpm
½”
4165K114
3223-02T0-11 / .5-5
1 - 10 gpm
½”
4165K124
3223-02T0-11 / 1-10
1.5 – 15 gpm
¾”
4165K134
3223-03T0-11 / 1.5-15
2 – 20 gpm
1”
4165K144
3223-04T0-11 / 2-20
5 – 50 gpm
1”
4165K154
15 – 150 gpm
1-1/2”
4165K164
3223-06T5-11 / 15-150
25 – 250 gpm
2”
4165K174
3223-08T5-11 / 25-250
30 – 300 gpm
3”
4165K184
VERTICAL
UP é
FLOW
DIRECTION


Flow Range (gpm)
SIZE
MC   p/n
ERDCO p/n
0.5 – 5 gpm
½”
4165K115
3224-02T011 / .5-5
1 - 10 gpm
½”
4165K125
3224-02T011 / 1-10
1.5 – 15 gpm
¾”
4165K135
3224-03T011 / 1.5-15
2 – 20 gpm
1”
4165K145
3224-04T011 / 2-20
5 – 50 gpm
1”
4165K155
3224-04T011 / 5-50
15 – 150 gpm
1-1/2”
4165K165
3224-06T011 / 15-150
25 – 250 gpm
2”
4165K175
30 – 300 gpm
3”
4165K185
3224-12T011 / 30-300
VERTICAL
DOWN ê
FLOW
DIRECTION


Please note,  SEE-FLO METERS can come in gpm ranges specified to your specific application.

Also the connection type can be any of the following:

NPT END
NPT BACK
TRI-CLAMP
GROOVED
BEVELED
SOCKET (1/2 - 1 inch)
FLANGE (150#RF)
FLANGE (150#FF)
FLANGE (300#RF)
FLANGE (300#FF)
FLANGE (DIN PN16)
BSPT End
BSPT Back


ERDCO®  ENGINEERING  COMPANY offers a complete line of flowmeters, sight flow indicators, flow transmitters and flow indicating switches. We employ elegantly simple measuring technologies with proven reliability in utility fluid applications.
Whether it's chilled water, air, nitrogen, steam, lube oil or other process support fluid, ERDCO has the flow measurement solution. Select from in-line and insertion styles that feature simplicity, rugged construction and reliable operation. This product range has great versatility across a broad set of applications.


Contact Anderson-Bolds at 216-360-9800 or via our CONTACT FORM
Ask for Jerry for your ERDCO Flow Meter needs and questions.
ERDCO Meters On Anderson-Bolds