CWH1000
Series - Commercial Fan-Forced Wall Heaters by Q'Mark Marley
• Fast heat response, compact design and
versatility make the CWH1000 Series heaters ideal for dens, basements,
converted attics, breezeways, garages, bathrooms, small offices, workshops and
similar areas. Also, adaptable to multiple installations in somewhat larger or
odd shaped room
• Fan delay: On a call for heat, element
is energized but fan is delayed until element is warm, eliminating the
circulation of cold air during start up. When the thermostat is satisfied, the
element is de-energized, but the fan continues until all heated air is
discharged providing longer component life and higher comfort level
• Motor is totally enclosed, impedance
protected with permanently lubricated bearings
• Airflow system maximizes air volume at
minimum noise level; 65 CFM
• Rugged louvered commercial grade steel
grille creates downflow air pattern
• This heater is designed for
installation in 2x4 or larger wall sections using the wall box provided. The
heater may also be surface mounted to the wall by using the Surface Mounting
Frame, Model No. CWHSM (order separately)
• Includes built-in disconnect switch
Northern White
baked enamel finish
Q'Mark CWH1101DS 1000/500 watts 8.4/4.2 amps
120 volts
Q'Mark CWH1151DS 1500/750 watts 12.5/6.25 amps 120 volts
Q'Mark
CWH1201DS 1800 watts
15 amps 120 volts
Q'Mark CWH1202DS 2000/1000 watts 8.3/4.2 amps
240 volts
Q'Mark CWH1157DS 1500/750 watts 5.5/2.75 amps
277 volts
Q'Mark CWH1207DS 2000/1000 watts 7.2/3.61 amps 277 volts
Q'Mark CWH1208DS 2000/1000 watts 9.6/4.8 amps 208 volts
Q'Mark CWHSM surface mounting frame (Accessory)
Q'Mark CWHS1 1 inch
Semi-Recess Mounting
Q'Mark CWHS2 2 inch
Semi-Recess Mounting
MOUNTING LIMITATIONS
1. Do not install heater closer than
4” from
floor.
2.Do not install heater behind towel
rack,
behind door, in floor, in ceiling, in
closet,
or where air flow may be obstructed.
HEATING ELEMENT: The heating element shall be of the
non-glowing design consisting of an
80/20 nickel-chromium
resistance wire enclosed in a steel
sheath to which plate fins
are copper brazed. It shall be
warranted for 5 years.The
element shall cover the entire air
discharge area to ensure
uniform heating of all discharge air.
MOTOR AND CONTROLS: The fan motor shall be
impedance protected, permanently
lubricated and with totally
enclosed motor. Fan control shall be
of the bi-metallic, snapaction
type and shall activate fan after
heating element
reaches operating temperature, and
continue to operate the
fan after the thermostat is satisfied
and until all heated air has
been discharged.The thermostat shall
be single pole type on
all models. Thermal cutout shall be
bi-metallic, snap-action
type designed to shut off heat in the
event of overheating. The
fan shall be five-bladed aluminum.
The fan motor shall be
totally enclosed.
216-360-9800