Thursday, July 26, 2018

Littelfuse Off Delay Adjustable Timer TDBL12D

Anderson-Bolds has in stock the Littelfuse Adjustable TDR working on 12vdc.  The TDBL12D can be shipped within 24 hours of an order.

LittelFuse SSAC TDR TDBL12D, with a .1-102.3 Second Adjustable Range. 10 amp rating and 12 volts DC (Octal Socket required). The Timer is an Delay-On-Break (Off Delay) time delay relay. The Time Delay Relay is now made by Little Fuse. UL, CSA and CE. Previous manufacturers were SSAC, Entrelac, ABB and Sycom. Littelfuse part number is TDBL12D

Buy the Timer/TDR HERE!



TBDL12D 


















Anderson-Bolds
216-360-9800
www.anderson-bolds.com

Monday, July 16, 2018

Parker's NEW G7 Solenoid Valves

New G7 valves from Parker and Anderson-Bolds


Parker's new generation of G7 solenoid valves delivers the confidence to get the toughest jobs done right. And thanks to advanced Parker technologies, success has never been easier. Ensuring high performance and an optimized total cost of ownership, Parker continues to focus on Engineering Your Success.

Call Anderson-Bolds for a quote.  216-360-9800
or email at sales@anderson-bolds.com














Markets 
Commercial Equipment 
Food & Beverage 
Industrial Automation 
Oil & Gas 
Process Control 

Specifications 
• Port Sizes: 1/8" - 3/8" NPT • Pressures: Up to 2200 psi • Flows: Up to 1.06 Cv 

Benefits 

Industry-Leading Performance 

High Pressures 
High Flows 
High Temperatures 
Corrosion Resistant 
Environmentally Resistant 

Premium Construction 
• 303 Stainless Steel • Lead-Free Brass* • IP67, Thermal Shock-Resistant Solenoid Coil • Engineered for Long Life • Proven Gold Ringand Skinner® Fundamentals 

Ease of Doing Business 
• 24-Hour Express Ship Program • Innovative Parker Tracking System (PTS) • Easy-Install Conduit Solenoid Coil • Simplified Installation and Service • Durable Laser-Marked Identification • Domestic Manufacturing and Support 

2-Way Normally Closed, Direct Acting - Stainless Steel  AC voltage
2-Way Normally Closed, Direct Acting - Stainless Steel  DC Voltage
2-Way Normally Closed, Direct Acting - Brass AC Voltage
2-Way Normally Closed, Direct Acting - Brass DC Voltage
2-Way Normally Open PIBOS*, Direct Acting - Stainless Steel 
* PIBOS (Pressure In Body, Out Sleeve): An economical approach to 2-Way Normally Open valves. 
   Pressure enters body, exits through sleeve on top of valve. 

PARKER G7 available COILS are :
C7F 120/60 with 1/2 NPT conduit, IP67, Nema 6
C7G 240/60 with 1/2 NPT conduit, IP67, Nema 6
C7E  24/60 with 1/2 NPT conduit, IP67, Nema 6

D7F 120/60  DIN Style, IP65, Nema 4X
D7G 240/60 DIN Style, IP65, Nema 4X
D7E  24/60  DIN Style, IP65, Nema 4X

B7F 120/60 with simple 18 inch leads, IP67, Nema 6
B7G 240/60 with simple 18 inch leads, IP67, Nema 6
B7E  24/60 with simple 18 inch leads, IP67, Nema 6

C7A  12VDC with 1/2 NPT conduit, IP67, Nema 6
C7B  24VDC with 1/2 NPT conduit, IP67, Nema 6

D7A  12VDC DIN Style, IP65, Nema 4X
D7B  24VDC DIN Style, IP65, Nema 4X

B7A  12VDC with simple 18 inch leads, IP67, Nema 6
B7B  24VDC with simple 18 inch leads, IP67, Nema 6

STAINLESS STEEL BASE VALVE PART NUMBERS ARE:
                         AC VOLTS    DC VOLTS
20CC02GV7   750 PSI          500 PSI
20CC02PV7    375 PSI          145 PSI
20CC02QV7    230 PSI          85 PSI
20CC04GP7    750 PSI          500 PSI
20CC04LV7     550 PSI          260 PSI
20CC04PV7    375  PSI          145 PSI
20CC04QV7    230 PSI            85 PSI
20CC04TV7     110 PSI            40 PSI
20CC041V7     40 PSI              20 PSI

BRASS BASE VALVE PART NUMBERS ARE:
20LC02PN7     375 PSI          145 PSI 
20LC02QN7     230 PSI          85 PSI 
20LC04GN7     750 PSI          500 PSI 
20LC04PN7      375 PSI          145 PSI  
20LC04QN7      230 PSI          85 PSI
20LC04TN7      110 PSI            40 PSI 
 20LC041V7       40 PSI              20 PSI

Call Anderson-Bolds for a quote.  216-360-9800

ANDERSON-BOLDS 
BEACHWOOD, OHIO

Wednesday, July 4, 2018

SSAC/Littelfuse Voltage Monitor HLMUDLAAA

Voltage Monitor Protection Relay HLMUDLAAA from Anderson-Bolds
Made by Littelfuse

Contact Anderson-Bolds

LittelFuse SSAC Voltage Monitor HLMUDLAAA is a universal voltage monitor. 10 amp output relay rating. The HLM Voltage Monitor senses over or under voltage AND phase unbalance and frequency fluctuations and trips if any go oout of range. The Voltage Monitors are currently made by Little Fuse. UL, CSA and CE. Previous manufacturers were SSAC, Entrelac, ABB and Sycom.

BUY the HLMUDLAAA


The HLMU Series is a universal voltage, encapsulated, 3-phase voltage monitor. It continuously measures the voltage of each of the three phases with microcontroller accuracy and compares the value to preset trip points. It separately senses phase reversal and loss; over, under and unbalanced voltages; and
over or under frequency. Protection is assured during periods of large average voltage fluctuations, or when regenerated voltages are present. The unit trips within 200ms when phase loss is detected. Adjustable time delays are included to prevent nuisance tripping and short cycling of sensitive equipment. The isolated, 10A, DPDT relay contacts trip when a phase voltage exceeds the trip limits for the trip delay. Nominal line voltage, voltage unbalance, and time delays are knob adjustable. The phase loss setpoint and the acceptable frequency range are fixed. Both delta and wye systems can be monitored; no connection to neutral is required.


Voltage Monitor HLMUDLAAA


BENEFITS
Constant monitoring to protect against phase loss, phase reversal; over, under, and unbalanced voltage; over and under frequency
Flexibility to work in 200 to 480VAC applications
Installation flexibility
Provides diagnostics of relay, fault and time delay status
Protects against shock, vibration, and humidity Meets IEC 61000 safety requirements

Operation
Upon application of line voltage, the output is de-energized
and the restart delay begins. If all the three-phase voltages are within the acceptable range, the output energizes at the end
of the restart delay. The microcontroller circuitry automatically senses the voltage range, and selects the correct operating frequency (50 or 60Hz). The over and under voltage trip points are set at ± 10% of the adjusted line voltage. When the measured value of any phase voltage exceeds the acceptable range limits (lower or upper) the trip delay begins. At the end of the trip delay the output relay de-energizes. If the phase voltage returns to an acceptable value before the trip delay expires, the trip delay is reset and the output remains energized. Under, over, and unbalanced voltages plus over or under frequency must be sensed for the complete trip delay before the unit trips. The unit trips in 200ms when phase loss or reversal are sensed. The unit will not energize if a fault is sensed as the line voltage is applied. 


Reset: Reset is automatic upon correction of the voltage or frequency fault or phase sequence.


Restart Delay Options
L = Lockout or minimum OFF time. The restart delay begins when the output trips. The unit cannot be re-energized until the restart delay is complete. This provides a minimum off time
or lockout time to allow equipment sensitive to short cycling, time to reset. If the fault is corrected after the restart delay is complete, the output energizes immediately. The restart delay also occurs when line voltage is applied/reapplied.
R = Restart Delay on fault correction. The restart delay begins when line voltage is reapplied or when a voltage fault is corrected. This option is normally selected when staggered restarting of multiple motors on a power system is required.
N = No Restart Delay. 0.6 second initialization delay on application of line voltage applies.
Restart Notes: All restart options remain reset when the following conditions are detected:
1. Phase loss (phase unbalance greater than 25%) 2. Average line voltage less than 120VAC
3. Phase reversal

The restart delay begins when the condition is corrected.


LED Operation
The LED flashes green during the restart delay, then glows green when the output energizes. It flashes red during the trip delay then glows red when the output de-energizes. It flashes red/green if phase reversal is sensed. If a fault is sensed during the restart delay, the LED will glow red during that portion or the full restart delay. 


Type

3-phase delta or wye with no connection to neutral


Range
240 380 480
Voltage Adj. Range
200-240VAC 340-420VAC 400-480VAC
Frequency
50 or 60Hz 50Hz 60Hz

Line Voltage Max.
550VAC
AC Line Frequency
50/60 Hz automatically detected
Phase Loss
≥ 25% unbalance
Response Time
≤200ms 

Overvoltage Trip Voltage 
109 - 113% of the adjusted line voltage
 Reset Voltage
-3% of the trip voltage

Undervoltage Trip Voltage
88 - 92% of the adjusted line voltage
Reset Voltage
+3% of the trip voltage 

Voltage Unbalance Trip Setpoint
Adjustable 2 - 10% or specify fixed unbalance of 2 - 10% in 1% increments
Reset on Balance
-0.7% unbalance
Trip Delay Active On
Over/under voltage, voltage unbalance, over/under frequency

Range
Adjustable from 1 - 30s or specify fixed delay 1 - 30s in 1s increments
Tolerance
±15%
Restart Delay Range
Adjustable from 0.6 - 300s; if no restart delay is selected a 0.6s initialization delay applies 

Tolerance


±15%
Over/Under Frequency
±4%; Reset ±3%; 50/60 Hz
Phase Sequence
A, B, C, L1, L2, L3
Response Time-Phase
Reversal & Phase Loss
≤200 ms
Reset
Automatic

Output 

Isolated Electromechanical Relay


DPDT


10A resistive @ 240VAC;
8A resistive @ 277VAC; NO-1/4 hp @ 120VAC; 1/3 hp @ 240VAC

Protection
Phase Reversal/Failure

ASME A17.1 Rule 210.6
Motors and Generators
NEMA MG1 14:30, 14:35
Surge
IEEE C62.41-1991 Level B
Isolation Voltage
≥ 2500V RMS input to output
Circuitry
Encapsulated

Dimensions
H 76.7 mm (3.0”); W 50.8 mm (2.0”);
D 41.7 mm (1.64”)

Termination
Screw terminal connection up to 12 AWG (3.3 mm2) wire
  
 Temperature
 -40° to 60°C / -40° to 85°C

BUY the HLMUDLAAA
www.anderson-bolds.com
Anderson-Bolds
216-360-9800