Altech Corp. provides Automation and Control components and ATEX Rated products.
For a quote, please click HERE!
Aluminum and Polyester Enclosures
Cable Gland - ATEX Polyamide
Snap-action Switch
Position Switch series ENM2 and GC, Rope Pull Switch SD
Sensors
DIN Rail Terminal Blocks
Circuit Breaksers
Altech is a US leader in DIN rail mounted breakers with ratings up to 63A. Only Altech offers DIN rail mounted breakers that meet UL489, UL508 or UL1077 approvals with a short circuit interrupt capacity of up to 10kA.
When you need branch circuit protection, Altech offers UL489 Miniature Molded Case Circuit Breakers in both AC and DC voltages. The AC version offers dual voltage rated circuit breakers at 0.2-63A/240VAC and 0.2-32A/480Y/277VAC in 1-3 poles. Altech is the only company that offers a 14kA, 20A C curve single phase breaker at 277V AC. The DC version offers 0.2-63A at 125V (1 pole) and 250V (2 pole).
If your application requires a manual motor controller, Altech is the leading US supplier of UL508 Manual Motor Controllers (MMC). In AC, we offer up to 60A in 1 to 3 poles at 480Y/277VAC. With 6 trip curves, Altech has the largest selection in the industry. This ensures you the selectivity you require for your application designs. Our MMCs have a 10kA short circuit withstand capacity, this is the highest rating in the industry. The AC version is rated up to 60A and is DC rated in 2 poles up to 80VDC.
When your application requires supplemental protection for control circuits and on the load side of branch circuit protectors Altech has solutions. We offer a competitive line of AC Supplementary Protectors, up to 63A, in 1 to 3 poles at 480Y/277VAC with a 10kA short circuit withstand rating.
ALTECH HAS THE MOST COMPLETE LINE OF UL GROUND FAULT EQUIPMENT PROTECTION PRODUCTS IN THE INDUSTRY.
The UL 489 Branch Circuit with Ground Fault Relay is the 1st in the industry! Since it includes a UL 489 Branch Circuit Protector, in many cases there is no need for upstream circuit protection. It comes in 1+N pole, 2 pole and 2 pole +N configurations at 240V AC, 120/240V AC. It has a rated current of 5 - 40A. It also has a Rated Short Circuit Interrupt Capacity of 10kA and comes in Overload tripping curves B, C and D. The Rated Frequency is 50/60Hz.
The UL 1053 approved device comes in 1 pole + N and 3 pole + N at 277V AC, 480Y/277V AC. It has a Rated Current of 25, 40 and 63A. It also has a Rated Short Circuit Withstand Capacity of 10kA and a Rated Frequency of 50/60Hz.
The GF Series of Equipment Ground Fault Protection Relays (Earth Leakage Protection) is providing ground fault (residual current) as well as pulsating DC ground fault protection for circuits with loads up to 63A.
The UL 1077/1053 device comes in 1 pole + N and 3 pole + N at 277V AC, 480Y/277V AC. Rated Current ranges from 5 - 40A. It also has a Rated Short Circuit Withstand Capacity of 10kA, and comes in Overload tripping curves B, C and D. The Rated Frequency is 50/60Hz.
The GFR Series is a combined Equipment Ground Fault Relay and Supplementary Protector (RCBO) is designed to provide protection against overloads and AC ground faults (residual current faults) as well as pulsating DC ground faults.
Power Distribution Blocks
- Speed of mounting and wiring
- IP20 Finger Safe
- DIN Rail or Panel Mount
- Blocks fit with other DIN Rail mountable modular devices (height 95mm, depth 44.5mm)
- Accessories increase the number of outputs with only one input
RCCB Earth Leakage Circuit Breakers
Compact DIN rail mount RCCB Earth Leakage Circuit Breakers detect and interrupt ground faults. They are VDE approved for the European system of protecting people, animals, equipment and property from dangerous line-to-ground and shock hazard currents.
US applications include ground fault protection of equipment (GFPE), especially when high distributed capacitance or other leakages cause excessive nuisance trips at lower fault currents.
TR SeriesUS applications include ground fault protection of equipment (GFPE), especially when high distributed capacitance or other leakages cause excessive nuisance trips at lower fault currents.
- RCCB Four Pole, 2- or 3-Phase
- RCCB Two Pole, Single Phase
- Electrical Ratings:
16-63A / 415Y/240V AC - Trip Capable on Decayed Line Voltage
- Marked Approval of VDE
- Marked "Snowflake" Temperature Range (-25 to 40 °C [-13 to 104 °F])
- Marked Trip Sensitivity to Pulsed as well as Sinusoidal Fault Currents
- Integral Test Circuit
- Insensitive to Vibration, et
UL1077 Recognized
Supplementary Protector/
Circuit Breaker for Equipment
Electrical Ratings: 0.5-16.0A / 240V AC, 50/60Hz, 32V DC / 24V DC (VDE)
Applications:
Protection of Control Transformers, UPS, Power strips, Solenoids etc., against damage due to
overload conditions.
Protection of Control Transformers, UPS, Power strips, Solenoids etc., against damage due to
overload conditions.
Motor Disconnect Switches
- One of the smallest 80A switches in the industry
- Advanced switch technology (use of silver contacts ensures safe and durable operation)
- Across the line, motor starting - up to 75hp/600V
- General Use Rating - 16A to 150A/600V
- Available as rotary switches for extended or direct handle
- Toggle switches
- Non-fused switch
- Short Circuit withstand Ratings 10kA with back-up fuse
- DIN Rail and panel mount available
- Comprehensive range of accessories includes Door Mounting Kits & Fuse Holder
- Snap on auxiliary contacts
- Enclosed switches with UL 4, 4X Type 4x rating
- AC Motor Across-the-line
- AC General Use
- Horsepower Ratings
- DIN Rail Mount
Extended / Direct Handle Motor Disconnect SwitchThe KU/VKA...N series can be used with extended and direct handles.
- 3-4 poles
- General Purpose Current: 25A - 150A
- Maximum Voltage: 600V AC
- Motor FLA @ 480V AC: 17.5A - 34A
- Motor FLA @ 600V AC: 11A - 83A
- 1 Phase and 3 Phase Horsepower Rating
- Short Circuit withstand Rating at 600V with Max. Fuse
- Terminal Size Acceptability: 14-8AWG - 4-1/0AWG
Extended Handle Accessories
- Door Interlock Handles
- Door Interlock Shaft
- Auxiliary Switches
- Fuse Holder
- Direct Handles
- Door Mountng Kits
DRILL TEMPLATES:
LK10
LK11
OKA 0V LK2
OKA KU LK10 - Mounting Alternatives - Aluminum DIN Rail
Polycarbonate Enclosed Motor Disconnect Switch
These enclosed switches can be used locally at the motor.
- Can be used locally at the motor
- UL Type 4X
- IEC IP65 Protection Level
- UV resistant
- Resistant to many chemicals
- Lockable - Defeatable Handle
Aluminum Enclosed Motor Disconnect Switch
Stainless Steel Enclosed Motor Disconnect Switch
These enclosed switches can be used locally at the motor.
- UL Type 4
- Excellent in harsh weather conditions
- UV resistant
- Resistant to many chemicals
- IP66 Protection Level
- Lockable and Defeatable Handle
These enclosed switches can be used locally at the motor.
- UL Type 4X
- Ideal where chemicals are used for cleaning and maintenance such as food processing and breweries
- Mining is another application area
- Stainless Steel (Grade AISI 316)
- Corrosion Resistant
- IP66 Protection Level
- Lockable - Defeatable Handle
216-360-9800
www.anderson-bolds.com