GRIEVE NBS-400 Bench Oven - Class A

Class A Oven by Anderson-Bolds and Grieve Corporation


Model NBS-400 meets the requirements of OSHA and National Fire Protection Association Standard 86 for Class A ovens. Not for use in hazardous locations as defined in the National Electric Code.

These rugged bench ovens are designed for a wide variety of industrial heat processing applications including those where flammable solvents or vapors will be present in the oven.

STANDARD FEATURES

— Recirculating blower
— 304 stainless steel interior
— Incoloy sheathed tubular heating elements
— Silicone rubber door gasket
— Analog, thermocouple actuated, temperature controller
— Adjustable, thermocouple actuated, manual reset excess
     temperature interlock
— On-off switch
— Red pilot light indicates heater operation
— Sturdy steel construction
— Brushed stainless steel exterior
— 6 lb/cf density industrial rockwool insulation
— Built-in baffles prevent radiant heat
— Fully factory tested
— 1 year limited warranty

MODEL NBS-400
Fan forced recirculation of heated air throughout 7 cubic foot work space at temperatures to 400°F. Includes two (2) removable nickel plated wire shelves easily adjustable on 2" centers. Holds a maximum of seven (7) shelves. Includes safety equipment required when flammable solvents or vapors are present in an oven.

Grieve NBS Class A Bench Oven


STANDARD EQUIPMENT 
• Standard Electrical Characteristics
— 208 volts, 1-phase, 60 Hz
— 230 volts, 1-phase, 60 Hz
— Other electrical characteristics available

MODEL NBS-400
Completely wired control panel assembled on the oven enclosing the temperature controller, manual reset excess temperature interlock, pilot light to indicate when heaters are energized and on-off switch. Includes additional safety equipment required by OSHA and NFPA 86 for Class A ovens. Will handle a maximum of 3 ounces (0.024 gallons) of flammable solvents or vapors per batch at a maximum temperature of 400°F. 


• Manual Reset Excess Temperature Interlock
Turns off heat if oven exceeds 400°F.

• Back-Up Heating Element Relay
Turns off oven heat on excess temperature controller actuation in the
event of failure of the primary heating element relay


• 35 CFM Separately Powered Forced Exhauster
Provides safety ventilation. Exhaust outlet 4" diameter.


• Exhauster Air Flow Safety Switch
Turns off oven heat if exhauster fails


• Recirculating Blower Air Flow Safety Switch
Turns off oven heat if recirculating blower fails


• Purge Timer
Provides time delay to allow exhauster to pull four oven volumes of
air through the oven prior to turning oven heat on


Contact Anderson-Bolds for all your Electric Processing needs.
We can enhance your production.
216-360-9800

Saturday, October 5, 2013

Grieve Walk-In Batch Ovens

Anderson-Bolds is the Ohio and Kentucky Rep for  GRIEVE  Ovens

Use Our Grieve Oven Application Data Sheet or call 216-360-9800


Grieve Walk-In Ovens

Grieve Walk In Ovens for paint baking, drying, preheating, annealing or any other heat processing of large or numerous parts at temperatures to 750°F. Oven size conveniently accommodates materials handling equipment. Choice of either combination or full horizontal air flow in either rear or top mounted heat chamber configurations. Designed and constructed for long, hard, continuous use.


STANDARD FEATURES

• UL ul1.gif LISTED CONTROL PANEL 
• Standard Truck Ovens from Grieve meet the requirements of National Fire Protection Association Standard 86, Industrial Risk Insurers, Factory Mutual and OSHA standards. For some applications, such as those involving flammable solvents or hazardous locations, the above organizations require additional safety devices.
• Controls
— Digital, microprocessor based, thermocouple actuated, indicating temperature controller
— Modulating burner on gas ovens
— Motor control push buttons and on-off heat switch
— LED pilot lights
• Safety Equipment — Electric Oven
— Adjustable, thermocouple actuated, manual reset excess temperature interlock
— Separate heating element control contactors
— Recirculating blower air flow safety switch
• Safety Equipment — Gas Oven
—Adjustable, thermocouple actuated, manual reset excess temperature interlock
—Electronic flame safeguard protection
—Powered forced exhauster for combustion venting
—Exhauster air flow safety switch
—Recirculating blower air flow safety switch
—Two pilot safety shutoff valves with leak test stations
—Two main safety shutoff valves with leak test stations (Industrial Risks Insurers vent valve only provided on specific request)
—Valve position indicator on main safety shutoff valves
—Over 400,000 BTU/HR safety shutoff valve interlocked with
purge timer
—Purge timer
—High gas pressure switch
—Low gas pressure switch
• Construction
—Choice of air flow patterns
—Adjustable opposed louvers on full coverage supply and return
duct work
—Choice of rear or top heat chamber
—Available with doors at each end
—Choice of floor configurations, flat plate, insulated floor, truck
wheel guide tracks
—Exceptionally heavy duty doors
—Aluminized steel interior
—Aluminized steel exterior with enamel finish
—High temperature door gasket with stainless steel spring insert
—6 lbs/cf density industrial rockwool insulation
—Brushed stainless steel control panel face
—1 year limited warranty
• Every oven fully assembled and individually factory tested 

STANDARD EQUIPMENT
• All Models
— 208 volts, 3-phase, 60 Hz
— 230 volts, 3-phase, 60 Hz
— 460 volts, 3-phase, 60 Hz
— Other electrical characteristics available

Aluminized steel interior. Carbon steel structural members and steel plate painted with high temperature aluminum paint. Trilite Green enamel painted aluminized steel exterior. 

Two Air Flow Patterns Available
Combination air flow for random shapes and sizes or for large bulky objects where heated air can move upward, around and through the load. Horizontal air flow for applications where heated air must move sideways to pass through a load such as trays or flat sheets. See circulation diagrams below.

Horizontal Air Flow
Heated air is blown horizontally across the work space between full coverage duct work. For shelf truck loading applications with densely loaded shelves, solid bottom trays, or flat sheets where heated air can only pass sideways above and below each level. Also used on oven floor or loaded on a flat bed truck. 

Combination Air FlowHeated air is provided from full coverage supply duct work at each side of the work space and sweeps upward through the load to a return duct at the top of the work space. Used in most shelf truck loading applications where sufficient shelf area is left open to allow vertical air movement upward through the loaded truck. Ideal for large parts placed directly on oven floor or loaded on a flat bed truck.


Two Oven Configurations Available
Rear heat chamber for easy handling, low profile equipment. Top mounted heat chamber to minimize factory floor space occupied or to allow installation of doors at each end. Doors on front and rear allow for pass through operation or for loading from both ends.

To facilitate shipping and handling, top mounted heat chamber ovens are available with removable heat chambers. These ovens are fully assembled and tested. They are then sectioned and match-marked for easy reassembly at destination by customer.
Ovens come standard with steel plate floor and doorsill which oven doors seal against. If specified, doorsill can be eliminated and doors provided with drag seals. Up to 6' wide work space, plate floor is 1/8" thick. Wider ovens have 1/4" plate floor. Provisions for customer installed insulated floor are included. Optional factory installed insulated floor is available. See Bulletin WI-513.
Optional truck wheel guide tracks for loading equipment are available. Guide tracks can be installed on steel plate floor, recessed into insulated floor, or installed on top of insulated floor. See Bulletin WI-513.
Optional loading trucks specifically designed for use in each oven are available. Loading trucks come in shelf loading models with removable shelves or as heavy duty flat bed models with grating surface. See Bulletin WI-513.
• Electric Models
Each features completely wired, side access UL listed control panel enclosing terminals for incoming power, temperature controllers, push buttons and pilot lights. Motor starter and heating element contactors electrically interlocked to shut off heaters if power to blower is interrupted and to permit operation of blower without heat for cooling. Incoloy sheathed tubular heating elements.

• Gas Models
—1,000 BTU natural gas at 6" water column pressure: 
1" NPT inlet to 350,000 BTU/HR; 
1-1/4" NPT to 1,200,000 BTU/HR
— Other gas characteristics available

Control panel as detailed above and safety devices as listed on the front of this bulletin. A 325 CFM powered forced exhauster is included up to 800,000 BTU/HR; at 1,200,000 BTU/HR a 650 CFM exhauster is included. Both exhausters have 6" outlets. Automatic pre-ignition purge period and push button electric ignition contributes to ease of operation. Modulating gas burner is protected with electronic flame safety relay.