Meltric DS Series DeContactors ~ Industrial Plugs

Meltric DS20 Switch Rated Plugs from Anderson-Bolds

Meltric Plugs make Safety Easy and safe money and time when changing motors, fans, pumps and lighting. The Switch rated Meltric plug and receptacles are NEC listed as a "Line of Sight" Disconnect!



The versatile DS Series plugs and receptacles offer the highest amperage range. Most models are available in metal or Poly material.

  • 20A to 200A
  • Max 25hp
  • NEMA 3R (4X option)
  • Poly or Metal Casing

Choose DS Series for its...
Switch & horsepower ratings
Higher amperage range (20-200A)
Poly or metal casings (some sizes)

Common Applications
Most industrial applications
High hp motor applications



 Using Meltric DS20 Decontactor plugs and receptacles to connect motors instead of hard-wiring can help to reduce equipment change-out downtime by as much as 50%. When replacement motors are pre-wired with Decontactor inlets or plugs, a mechanic can safely perform the electrical connections simply by unplugging the old motor and plugging in the new one.
  • No waiting for an electrician to perform field wiring
  • No “suiting-up” or extraordinary electrical precautions
  • No need to field test (jog the motor) to ensure proper rotation


Sections 430.102 – 430.109 of the National Electric Code require approved disconnecting means to be located in a readily accessible location within sight of the motor and driven equipment. With their UL & CSA ratings for “Motor Circuit Disconnect Switching” and “Branch Circuit Disconnect Switching”, Decontactor devices are an approved ‘line of sight’ disconnect switch for meeting this requirement.


Lock Out Tag Out made easy with the Switch Rated Meltric deContactors.

DS 20 Series are 20 amp rated industrial Plugs and Receptacles.


Voltage: 600VAC;  250 VDC
Switch Ratings (AC Only)
Branch Circuit and Motor Circuit Disconnect Switch

Horsepower Ratings:
120V 1P   1/2 HP
208V 3P   3 HP
240V 3P   3 HP
480V 3P   5 HP
600V 3P   7.5 HP

Short Circuit Rating
100kA Close & Withstand Testing was performed with RK1 current limiting fuses sized at 400% of the highest full load motor ampacity associated with the devices hp rating.

Environmental Ratings
NEMA 3R, IP54/IP55* *IP54 when the plug & receptacle are mated. IP55 on the receptacle alone when the lid is latched closed.

UL listed 1682 for Plugs and receptacles.
UL listed 2682 for Branch circuit disconnect and Motor Circuit Disconnect.


A Typical System would be:

A Box with Angle (31-1A053-808-12)


480/3/60 Receptacle (33-14043) 



480/3/60 Male Inlet (33-18043 ) 



Poly Handle  (FH111)



Click on the above to view and purchase.  Thank you.





www.anderson-bolds.com
216-360-9800

Saturday, December 17, 2011

Meltric DSN Spec


Anderson-Bolds and Meltric present the DSN series of deContactor. Safety First.

Detailed spec for MELTRIC DECONTACTOR Series Switch Rated Plugs & Receptacles

Note to specifying engineer: In order to specify Meltric DECONTACTOR Series plugs and receptacles, include one or all of the items below in your job specification. The items in bold are exclusive to Meltric Decontactors and thus should be included in the specification wherever practical to avoid substitution of pin and sleeve or twist type devices.

  1. Plugs and receptacles must be listed to UL Subject 2682 'Switch Rated Plugs and Receptacles.' (Alternate for Canada: Plugs and receptacles must be CSA listed to UL Subject 2682 'Switch Rated Plugs and Receptacles').
  2. Plugs and receptacles must have constant pressure butt-contacts with solid silver-nickel tips. Pin and sleeve contacts are not permitted.
  3. Receptacles must have dead front construction: live parts must be inaccessible to thin tool or wire.
  4. Plugs and receptacles must be able to close at least once on a conditional short-circuit current of 65,000A. (Short circuit testing should be performed with RK1 current limiting fuses sized at 400% of the highest full load motor ampacity associated with the device).
  5. Plugs and receptacles must incorporate an integral switching mechanism to ensure the load is broken before the plug is removed from the receptacle.
  6. Plug and receptacle wire terminals must be spring-assisted to prevent loosening due to conductor yielding, shocks, vibrations or thermal cycling.
  7. The minimum environmental rating of plugs and receptacles must be NEMA 3R (DS Series), NEMA 4X and IP 66+67 (DSN Series), or IP67 (DB Series).
  8. Ingress protection must be achieved automatically when the plug is fully inserted into the receptacles, without additional manual operation (except DB Series).
  9. Plugs and receptacles must have a system of different keying positions in order to discriminate between circuits or incompatible operating voltages or frequencies.
  10. Plugs and receptacles installed outdoor must be able to withstand UV radiation.
  11. Plugs and receptacles shall be Meltric Decontactor Series or equal.


866-360-9810