Process Ovens Over 40 years Old


Safety Updates for Older Ovens.

 

Most Process ovens made over 40 years ago did not include an excess temperature controller or separate heating element contactors to protect the oven from overheating if the main temperature controller or contactors fail. 
 Any ovens like this should not be used until this safety equipment is installed.  Failure to install this safety equipment could result in the oven overheating and a fire that could result in oven damage, loss of the product load, building damage and injury to personnel.
 

A field kit to add the excess temperature controller and separate contractors should be ordered from the MFG.

The excess temperature controller and separate contactors are now standard equipment on all Grieve ovens.  Also standard is a recirculating blower airflow safety switch to shut down the oven heat if the recirculating blower fails.  This is a pressure differential switch that senses the pressure created when the blower wheel is turning.  This switch protects the oven heating elements by preventing them from heating when air is not being recirculated over them.  A field kit for installation of the recirculating blower airflow safety switch should be purchased from the oven MFG.


When installing new safety equipment it can be a good idea to add other new electronics to the oven for better performance.  New electronics could be a digital temperature controller, programmable digital temperature controller, new thermocouples or a digital timer.  Grieve can provide a field kit to add a digital temperature controllers as well as and a field kit for a digital shut down timer. For electric Ovens new elements can be ordered as well along with pin and sleeve disconnect switches for added electrical safety for personnel. We can provide Gas meters for gas ovens to measure gas flow at the oven and shut the oven down in a dangerous situation.

Grieve's field kits include installation instructions, wiring diagram showing items to be removed, wiring diagram showing items to be added and revised wiring diagram for your records.  Our kits will be based on how the ovens were constructed when they left our factory.  If there have been changes made to the oven in the field they will not be included in our revised wiring diagram.   


Grieve will provide all parts except for standard wire, conduit and conduit fittings.  These items are better provided in the field as necessary to connect the components being added.  Conduit would only be required for the air flow safety switch as the other items are mounted in the oven control panel.

Please contact Anderson-Bolds with the oven serial number, job # and model number all of which can be found on the name plate of the oven.  We can also provide new wiring schematics for old ovens and instruction manuals.  Grieve and Anderson-Bolds want our products to be operated in the safest manner possible. 


Contact Anderson-Bolds at:
216-360-9800 
grieve@anderson-bolds.com


Monday, October 26, 2015

Meltric deContactors Voltage color coding

Meltric deContactors from Anderson-Bolds provide safe connection of power to motors, pumps, heaters, compressors, HVAC Equipment and welders.
Meltric color codes their Plugs and receptacles based on voltage and pin combination.
Both the inlet and receptacle have the color coding for visual indication that the plugs go together add all as being pinned the same.

216-360-9800
Contact Anderson-Bolds regarding Meltric

1 pole 1 neutral and1 ground - 1P+N+G

110-125 volts 60 Hz  ORANGE
120-127 volts 60 Hz  YELLOW
255-277 volts 60 Hz  GREY
347 volts        60 Hz  RED

Two Poles and 1 Ground  - 2P+G

208-220 volts 60 Hz  BLUE
220-250 volts 60 Hz  ORANGE
440-480 volts 60 Hz  RED
600 volts        60 Hz  BLACK

Two Poles Neutral and 1 Ground  - 2P+N+G

110-125 volts 60 Hz ORANGE
220-250 volts 60 Hz ORANGE
208-220 volts 60 Hz BLUE
255-277 volts 60 Hz RED
440-480 volts 60 Hz RED
347-600 volts 60 Hz BLACK

Three Poles and One Ground - 3P+G

208-220 volts 60 Hz BLUE
220-250 volts 60 Hz ORANGE
440-480 volts 60 Hz RED
600 volts        60 Hz BLACK

Three Poles, One Neutral and One Ground - 3P+N+G

110-125 volts 60 Hz ORANGE
220-250 volts 60 Hz ORANGE
120-127 volts 60 Hz BLUE
208-220 volts 60 Hz BLUE
255-277 volts 60 Hz RED
440-480 volts 60 Hz RED
347-600 volts 60 Hz BLACK









Tuesday, May 14, 2013

Meltric Decontactor DS20 Repair / Spare Parts

Meltric Decontactors and Industrial plugs can be rebuilt as all the parts are replaceable.

The Meltric DS20 series of Industrial plugs and Receptacles are a 20 amp device with a Polyester housing and silver contacts. The Meltric DeContactor meets NEC codes and NFPA 70E Safety guidelines.  Below are the spare parts.  Note that the voltage and phasing are integral to the spare parts to the the parts are correct.  A 120 volt device will not fit into a 480 rated device. So when picking a part, please pick the correct voltage part or let us know the phasing and voltage.
the last three digits of the receptacle or inlet part number is the key.

Look for your part below or use our Contact Form and Anderson-Bolds will email a quote.

The DS20 Male Inlet parts diagram:


Part 1 is the Plug Interior*    31-1A010-xxx
Includes the Interior TOP and Interior BOTTOM
*(Need the voltage code, the last 3 digits of the part number)


31-1A010-076  125/250  Plug
31-1A010-073  250 volt  Plug
31-1A010-045  277 volt  Plug
31-1A010-043  480 volt  Plug
31-1A010-143  600 volt  Plug
(Others available, please call)


Part 2 is the Interior Bottom  31-1A010

Part 3 is the Interior Top*  31-1A010-xxx
*(Need the voltage code, the last 3 digits of the part number)

31-1A010-T-076  125/250  Plug
31-1A010-T-073  250 volt  Plug
31-1A010-T-045  277 volt  Plug
31-1A010-T-043  480 volt  Plug
31-1A010-T-143  600 volt  Plug
(Others available, please call)


Part 4 is the Locking Ring  31-1A583

Part 5 is the Plug Phase Contact  31-1A011-380
(If no aux. contacts.)


Part 5 is the Plug Phase Contact  31-1A011
(If there are aux. contacts.)

Part 5 is also the Plug Ground Contact  31-1A019


PART 6 is the color coded voltage Gasket
208V   31-1AB26   BLUE
250V   31-1AC26   ORANGE
480V   31-1AR26   RED
600V   31-1AN26   BLACK
125V   31-1AC26   ORANGE

Part 7 is the Plug Casing*  31-1A014-xxx
*(Need the voltage code, the last 3 digits of the part number)


31-1A014-076  125/250 Plug Casing

31-1A014-073  250 volt Plug Casing
31-1A014-045  277 volt Plug Casing
31-1A014-043  480 volt Plug Casing
31-1A014-143  600 volt Plug Casing
(Others available, please call)


The DS20 Female Inlet parts diagram:




Part 1 is the Receptacle Interior*    31-1A020-xxx 
Includes the Interior TOP and Interior BOTTOM
*(Need the voltage code, the last 3 digits of the part number)

31-1A020-076  125/250 Receptacle
31-1A020-073  250 volt Receptacle  
31-1A020-045  277 volt Receptacle
31-1A020-043  480 volt Receptacle
31-1A020-143  600 volt Receptacle
(Others available, please call)

Part 2 is the Interior Bottom  31-1A020

Part 3 is the Interior Top*  31-1A020-T-xxx
*(Need the voltage code, the last 3 digits of the part number)

31-1A020-T-076  125/250 Receptacle

31-1A020-T-073  250 volt Receptacle  
31-1A020-T-045  277 volt Receptacle
31-1A020-T-043  480 volt Receptacle
31-1A020-T-143  600 volt Receptacle
(Others available, please call)

Part 4 is the Locking Ring  31-1A583

Part 5 is the Plug Phase Contact  31-1A021-380
(If no aux. contacts.)

Part 5 is the Plug Phase Contact  31-1A021
(If there are aux. contacts.)


PART 6 is the color coded voltage Gasket
208V   31-1AB26   BLUE
250V   31-1AC26   ORANGE
480V   31-1AR26   RED
600V   31-1AN26   BLACK
125V   31-1AC26   ORANGE

Part 7 is the Receptacle Casing*  31-1A024-xxx
*(Need the voltage code, the last 3 digits of the part number)
31-1A024-076  125/250 Receptacle Casing

31-1A024-073  250 volt Receptacle Casing
31-1A024-045  277 volt Receptacle Casing
31-1A024-043  480 volt Receptacle Casing
31-1A024-143  600 volt Receptacle Casing
(Others available, please call)

Part 8 is the Lid Replacement kit 31-1A125

Part 9 is the PAWL Replacement kit 31-1A824

www.anderson-bolds.com
216-360-9800
CLEVELAND, OHIO USA

Friday, March 23, 2012

Meltric DSN 30 Part numbers

Anderson-Bolds and Meltric can supply 30 amp Pin and Sleeve connectors.
Meltric DSN plugs and receptacles are also disconnect switches.

If you have a Meltric Part number and you want a quote, please go to our contact FORM HERE

Spare parts are listed below.

61-3A010 DSN30 INLET INTERIOR
61-3A010-B DSN30 MALE INTERIOR BOTTOM
61-3A010-T DSN30 MALE INTERIOR TOP
61-3A011 DSN30 INLET CONTACT (W/PILOTS)
61-3A011-380 DSN30 INLET CONTACT W/O PILOTS
61-3A013 DSN30 HANDLE
61-3A013-1 DSN30 HANDLE
61-3A013-114 DSN30 HANDLE
61-3A013-12 DSN30 HANDLE
61-3A013-34 DSN30 HANDLE W/ 3/4" NPT
61-3A014 DSN30 INLET CASING
61-3A020 DSN30 RECEPTACLE INTERIOR
61-3A020-B DSN30 RECP INTERIOR BOTTOM
61-3A020-T DSN30 FEMALE INTERIOR TOP
61-3A021 DSN30 RECP CONTACT (W/PILOTS)
61-3A021-380 DSN30 RECP CONTACT W/O PILOTS
61-3A023-12 DSN30 CONDUIT BOX
61-3A023-34 DSN30 CONDUIT BOX
61-3A024 DSN30 RECEPTACLE CASING
61-3A024-843 DSN30 REC CASING W/PADLOCK PAW
61-3A027 DSN30 ANGLE, POLY
61-3A053-080-1 DSN30 ANGLE/BOX W/ 1" NPT
61-3A053-080-12 DSN30 ANGLE/BOX
61-3A053-080-34 DSN30 ANGLE/BOX
61-3A126 DSN30 INLET CAP
61-3A346 DSN30 FINGER DRAWPLATE KIT BAG
61-3A826 DSN30 LOCKING CAP
61-3AB26 DSN30 BLUE GASKET
61-3AC26 DSN30 ORANGE GASKET
61-3AJ26 DSN30 YELLOW GASKET
61-3AM26 DSN30 MARECHAL GASKET
61-3AN26 DSN30 BLACK GASKET
61-3AR26 DSN30 RED GASKET

Plugs, Receptacles, handles and angle boxes are below.

63-34042 DSN30 RECEPTACLE
63-34043 DSN30 RECEPTACLE
63-34043-270 DSN30 RECEPTACLE
63-34043-270-NC DSN30 REC W/MICROSWITCH
63-34043-375 DSN30 RECEPTACLE
63-34043-843 DSN30 RECEPTACLE
63-34043-972 DSN30 RECEPTACLE W/2 PILOTS
63-34043-972-348-A188 DSN30 REC W/2 PILOTS, 348 PAWL
63-34043-972-375 DSN30 RECEPTACLE
63-34043-972-NC DSN30 RECEPTACLE W/2 PILOTS
63-34045 DSN30 RECEPTACLE
63-34047 DSN30 RECEPTACLE
63-34047-972 DSN30 RECEPTACLE W/2 PILOTS
63-34072 DSN30 RECEPTACLE
63-34072-270 DSN30 RECEPTACLE W/MICROSWITCH
63-34073 DSN30 RECEPTACLE
63-34073-NC DSN30 RECEPTACLE
63-34075 DSN30 RECEPTACLE
63-34076 DSN30 RECEPTACLE
63-34142 DSN30 RECEPTACLE
63-34143 DSN30 RECEPTACLE
63-34143-972-270 DSN30 RECP 2PILOTS,MICROSWITCH
63-34147 DSN30 RECEPTACLE
63-34162 DSN30 RECEPTACLE
63-34163 DSN30 RECEPTACLE
63-34167 DSN30 RECEPTACLE
63-34167-375 DSN30 RECEPTACLE
63-38042 DSN30 INLET
63-38043 DSN30 INLET
63-38043-338-A188 DSN30 INLET W/ PRL AND
63-38043-972 DSN30 INLET W/2 PILOTS
63-38043-972-A188 DSN30 INLET
63-38045 DSN30 INLET
63-38047 DSN30 INLET
63-38047-972 DSN30 INLET W/2 PILOTS
63-38047-NNF DSN30 INLET
63-38072 DSN30 INLET
63-38073 DSN30 INLET
63-38073-972 DSN30 INLET W/2 PILOTS
63-38075 DSN30 INLET
63-38076 DSN30 INLET
63-38076-NNF DSN30 INLET
63-38142 DSN30 INLET
63-38143 DSN30 INLET
63-38147 DSN30 INLET
63-38147-972-NNF DSN30 INLET W/2 PILOTS
63-38162 DSN30 INLET
63-38163 DSN30 INLET
63-38167 DSN30 INLET

Buy DSN 30 Meltric parts here!

866-360-9810

Saturday, December 17, 2011

Meltric DSN Spec


Anderson-Bolds and Meltric present the DSN series of deContactor. Safety First.

Detailed spec for MELTRIC DECONTACTOR Series Switch Rated Plugs & Receptacles

Note to specifying engineer: In order to specify Meltric DECONTACTOR Series plugs and receptacles, include one or all of the items below in your job specification. The items in bold are exclusive to Meltric Decontactors and thus should be included in the specification wherever practical to avoid substitution of pin and sleeve or twist type devices.

  1. Plugs and receptacles must be listed to UL Subject 2682 'Switch Rated Plugs and Receptacles.' (Alternate for Canada: Plugs and receptacles must be CSA listed to UL Subject 2682 'Switch Rated Plugs and Receptacles').
  2. Plugs and receptacles must have constant pressure butt-contacts with solid silver-nickel tips. Pin and sleeve contacts are not permitted.
  3. Receptacles must have dead front construction: live parts must be inaccessible to thin tool or wire.
  4. Plugs and receptacles must be able to close at least once on a conditional short-circuit current of 65,000A. (Short circuit testing should be performed with RK1 current limiting fuses sized at 400% of the highest full load motor ampacity associated with the device).
  5. Plugs and receptacles must incorporate an integral switching mechanism to ensure the load is broken before the plug is removed from the receptacle.
  6. Plug and receptacle wire terminals must be spring-assisted to prevent loosening due to conductor yielding, shocks, vibrations or thermal cycling.
  7. The minimum environmental rating of plugs and receptacles must be NEMA 3R (DS Series), NEMA 4X and IP 66+67 (DSN Series), or IP67 (DB Series).
  8. Ingress protection must be achieved automatically when the plug is fully inserted into the receptacles, without additional manual operation (except DB Series).
  9. Plugs and receptacles must have a system of different keying positions in order to discriminate between circuits or incompatible operating voltages or frequencies.
  10. Plugs and receptacles installed outdoor must be able to withstand UV radiation.
  11. Plugs and receptacles shall be Meltric Decontactor Series or equal.


866-360-9810