WATLOW RM Multi-Zone CONTROLLERS



Integrated Multi-Function Controllers

EZ-ZONE® RM


The EZ-ZONE® RM controller simplifies thermal system management. The EZ-ZONE RM integrated controller family is comprised of six module types: an integrated on-off or PID control, monitoring and over/under temperature limit controller module, a high-density on-off or PID control module, a high-density limit-only module, an input/output (I/O) expansion module, a high-density monitor/scanner module and a data logging and field communications access module. A system is configured by connecting any combination of module types to address specific application needs. The EZ-ZONE RM is extremely flexible and scalable allowing mixing and matching of I/O to configure 1 to 152 control loops and up to 256 monitor points.

Multiple inputs; from 1 to 152 PID loops of control or monitor up to 256 analog inputs:

  • Mix and match I/O to fit any application; from 1 input with 2 outputs to 152 analog inputs with 152 outputs, or monitor up to as many as 256 analog inputs all in one system
  • Reduce cost because only required loops are purchased
  • Allows a common controller platform across many design applications as both loops and outputs can be ordered in single increments

Advanced PID control algorithm:

  • Offers TRU-TUNE®+ adaptive control to provide tighter control for demanding applications
  • Enables auto-tune for fast, efficient start-up

Communication capabilities:
Provides a range of protocol options including universal serial bus (USB) device port, Modbus® RTU, EtherNet/IP™, Modbus® TCP, DeviceNet™ and PROFIBUS DP

USB Port:
Provides data log retrieval

SPLIT-RAIL control:

  • Enables modules mounted in separate high-voltage and low-voltage cabinets to function as an integrated system
  • Minimizes the length and cost of wire runs and improves system reliability by locating inputs closer to sensors and outputs closer to load

AUTO CLONE:
Reduces time and configuration complexity by automatically building a new module with the same parameter settings as the replaced module

SENSOR GUARD:
Prevents unplanned process shutdowns and product loss by switching to a backup sensor if the primary sensor fails


Additional Key Functions
Configuration communication port (standard bus)
Removable modules and connectors
Ring lug and front-screw terminal options
Profile ramp soak with 400 total steps
Retransmit and remote set point input virtually inside controller eliminating costs for input/output hardware
User configuration settings can be stored and recalled
Thermistor input
Elevated operating range of 0 to 149°F (-18 to 65°C)
UL® listed, CSA, CE, RoHS, W.E.E.E. FM, SEMI F47-0200,
Class 1, Div. 2 rating on selected models