Showing posts with label Watlow. Show all posts
Showing posts with label Watlow. Show all posts

Wednesday, April 28, 2021

Watlow Power Series Controllers

 Watlow SCR Power Controllers from Anderson-Bolds

For a Quote Please use our Watlow Parts Form, HERE!

Watlow has manufactured solid state power controllers for over forty years. Watlow's POWER SERIES™ is a microprocessor-based product that features application flexibility unmatched by any other silicon controlled rectifier (SCR) power and solid state controller on the market today.

Watlow's POWER SERIES solid state controllers include single- and three-phase models from 65 to 250 amperes. Field configurable phase-angle or zero-cross firing improves application flexibility on-site where needed.

50/60Hz independent operation allows utilization almost everywhere in the world without special calibration considerations. Serial communication via Modbus® RTU allows setup and monitoring of load status from a computer station or control room.

On-board semiconductor fusing improves reliability by protecting the SCRs from heater short circuits. Plus, on-board heater bakeout and control diagnostics can help eliminate initial start up problems. All these benefits are in a touch-safe package that can be quickly and easily mounted in a control cabinet.

Watlow's POWER SERIES solid state controllers are UL® listed and C-UL® recognized, ensuring that they meet world safety and operational standards.

Watlow PC Power Controller SCR











Part numbers - Not Fan Cooled

Watlow PC10-N20A-0000

100 AMP, 1 PHASE, 24 TO 120V

Watlow PC10-N20B-0000

100 AMP, 1 PHASE, 200 TO 480V

Watlow PC10-N20C-0000

100 AMP, 1 PHASE, 200 TO 600V


Watlow PC20-N20A-0000

80 AMP, 3 PHASE, 2-LEG, 24 TO 120V

Watlow PC20-N20B-0000

80 AMP, 3 PHASE, 2-LEG, 200 TO 480V

Watlow PC20-N20C-0000

80 AMP, 3 PHASE, 2-LEG, 200 TO 600V

 

Watlow PC30-N20A-0000

65 AMP, 3 PHASE, 3-LEG, 24 TO 120V

Watlow PC30-N20B-0000

65 AMP, 3 PHASE, 3-LEG, 200 TO 480V

Watlow PC30-N20C-0000

65 AMP, 3 PHASE, 3-LEG, 200 TO 600V

 ------

 Watlow PC10-N25A-0000

140 AMP, 1 PHASE, 24 TO 120V

Watlow PC10-N25B-0000

140 AMP, 1 PHASE, 200 TO 480V

Watlow PC10-N25C-0000

140 AMP, 1 PHASE, 200 TO 600V


Watlow PC20-N25A-0000

105 AMP, 3 PHASE, 2-LEG, 24 TO 120V

Watlow PC20-N25B-0000

105 AMP, 3 PHASE, 2-LEG, 200 TO 480V

Watlow PC20-N20C-0000

105 AMP, 3 PHASE, 2-LEG, 200 TO 600V

 

Watlow PC30-N25A-0000

85 AMP, 3 PHASE, 3-LEG, 24 TO 120V

Watlow PC30-N25B-0000

85 AMP, 3 PHASE, 3-LEG, 200 TO 480V

Watlow PC30-N25C-0000

85 AMP, 3 PHASE, 3-LEG, 200 TO 600V

 ---------

 Watlow PC10-N30A-0000

165 AMP, 1 PHASE, 24 TO 120V

Watlow PC10-N30B-0000

165 AMP, 1 PHASE, 200 TO 480V

Watlow PC10-N30C-0000

165 AMP, 1 PHASE, 200 TO 600V


Watlow PC20-N30A-0000

130 AMP, 3 PHASE, 2-LEG, 24 TO 120V

Watlow PC20-N30B-0000

130 AMP, 3 PHASE, 2-LEG, 200 TO 480V

Watlow PC20-N30C-0000

130 AMP, 3 PHASE, 2-LEG, 200 TO 600V

 

Watlow PC30-N30A-0000

105 AMP, 3 PHASE, 3-LEG, 24 TO 120V

Watlow PC30-N30B-0000

105 AMP, 3 PHASE, 3-LEG, 200 TO 480V

Watlow PC30-N30C-0000

105 AMP, 3 PHASE, 3-LEG, 200 TO 600V

 ---------


Watlow PC11-N20A-1000

100 AMP, 1 PHASE, 24 TO 120V

Heater Diagnostics and Communications

Watlow PC11-N20B-1000

100 AMP, 1 PHASE, 200 TO 480V

Heater Diagnostics and Communications 

Watlow PC11-N20C-1000

100 AMP, 1 PHASE, 200 TO 600V

Heater Diagnostics and Communications 


Watlow PC21-N20A-1000

80 AMP, 3 PHASE, 2-LEG, 24 TO 120V

Heater Diagnostics and Communications 

Watlow PC21-N20B-1000

80 AMP, 3 PHASE, 2-LEG, 200 TO 480V

Heater Diagnostics and Communications 

Watlow PC21-N20C-1000

80 AMP, 3 PHASE, 2-LEG, 200 TO 600V

Heater Diagnostics and Communications 

 

Watlow PC31-N20A-1000

65 AMP, 3 PHASE, 3-LEG, 24 TO 120V

Heater Diagnostics and Communications 

Watlow PC31-N20B-1000

65 AMP, 3 PHASE, 3-LEG, 200 TO 480V

Heater Diagnostics and Communications 

Watlow PC31-N20C-1000

65 AMP, 3 PHASE, 3-LEG, 200 TO 600V

Heater Diagnostics and Communications 

 ------

Watlow  PC11-N25A-1000

140 AMP, 1 PHASE, 24 TO 120V

Heater Diagnostics and Communications 

Watlow PC11-N25B-1000

140 AMP, 1 PHASE, 200 TO 480V

Heater Diagnostics and Communications 

Watlow PC11-N25C-1000

140 AMP, 1 PHASE, 200 TO 600V

Heater Diagnostics and Communications 


Watlow PC21-N25A-1000

105 AMP, 3 PHASE, 2-LEG, 24 TO 120V

Heater Diagnostics and Communications 

Watlow PC21-N25B-1000

105 AMP, 3 PHASE, 2-LEG, 200 TO 480V

Heater Diagnostics and Communications 

Watlow PC21-N20C-1000

105 AMP, 3 PHASE, 2-LEG, 200 TO 600V

Heater Diagnostics and Communications 

 

Watlow PC31-N25A-1000

85 AMP, 3 PHASE, 3-LEG, 24 TO 120V

Heater Diagnostics and Communications 

Watlow PC31-N25B-1000

85 AMP, 3 PHASE, 3-LEG, 200 TO 480V

Heater Diagnostics and Communications 

Watlow PC31-N25C-1000

85 AMP, 3 PHASE, 3-LEG, 200 TO 600V

Heater Diagnostics and Communications 

 ---------

Watlow  PC11-N30A-1000

165 AMP, 1 PHASE, 24 TO 120V

Heater Diagnostics and Communications 

Watlow PC11-N30B-1000

165 AMP, 1 PHASE, 200 TO 480V

Heater Diagnostics and Communications 

Watlow PC11-N30C-1000

165 AMP, 1 PHASE, 200 TO 600V

Heater Diagnostics and Communications 


Watlow PC21-N30A-1000

130 AMP, 3 PHASE, 2-LEG, 24 TO 120V

Heater Diagnostics and Communications 

Watlow PC21-N30B-1000

130 AMP, 3 PHASE, 2-LEG, 200 TO 480V

Heater Diagnostics and Communications 

Watlow PC21-N30C-1000

130 AMP, 3 PHASE, 2-LEG, 200 TO 600V

Heater Diagnostics and Communications 

 

Watlow PC31-N30A-1000

105 AMP, 3 PHASE, 3-LEG, 24 TO 120V

Heater Diagnostics and Communications 

Watlow PC31-N30B-1000

105 AMP, 3 PHASE, 3-LEG, 200 TO 480V

Heater Diagnostics and Communications 

Watlow PC31-N30C-1000

105 AMP, 3 PHASE, 3-LEG, 200 TO 600V

Heater Diagnostics and Communications 

 

For a Quote Please use our Watlow Parts Form, HERE!

Part numbers - Fan Cooled

 

Watlow PC10-F20A-0000

125 AMP, 1 PHASE, 24 TO 120V

Watlow PC10-F20B-0000

125 AMP, 1 PHASE, 200 TO 480V

Watlow PC10-F20C-0000

125 AMP, 1 PHASE, 200 TO 600V


Watlow PC20-F20A-0000

120 AMP, 3 PHASE, 2-LEG, 24 TO 120V

Watlow PC20-F20B-0000

120 AMP, 3 PHASE, 2-LEG, 200 TO 480V

Watlow PC20-F20C-0000

120 AMP, 3 PHASE, 2-LEG, 200 TO 600V

 

Watlow PC30-F20A-0000

90 AMP, 3 PHASE, 3-LEG, 24 TO 120V

Watlow PC30-F20B-0000

90 AMP, 3 PHASE, 3-LEG, 200 TO 480V

Watlow PC30-F20C-0000

90 AMP, 3 PHASE, 3-LEG, 200 TO 600V

 ------

Watlow  PC10-F25A-0000

200 AMP, 1 PHASE, 24 TO 120V

Watlow PC10-F25B-0000

200 AMP, 1 PHASE, 200 TO 480V

Watlow PC10-F25C-0000

200 AMP, 1 PHASE, 200 TO 600V


Watlow PC20-F25A-0000

160 AMP, 3 PHASE, 2-LEG, 24 TO 120V

Watlow PC20-F25B-0000

160 AMP, 3 PHASE, 2-LEG, 200 TO 480V

Watlow PC20-F20C-0000

160 AMP, 3 PHASE, 2-LEG, 200 TO 600V

 

Watlow PC30-F25A-0000

140 AMP, 3 PHASE, 3-LEG, 24 TO 120V

Watlow PC30-F25B-0000

140 AMP, 3 PHASE, 3-LEG, 200 TO 480V

Watlow PC30-F25C-0000

140 AMP, 3 PHASE, 3-LEG, 200 TO 600V

 ---------

 Watlow PC10-F30A-0000

250 AMP, 1 PHASE, 24 TO 120V

Watlow PC10-F30B-0000

250 AMP, 1 PHASE, 200 TO 480V

Watlow PC10-F30C-0000

250 AMP, 1 PHASE, 200 TO 600V


Watlow PC20-F30A-0000

185 AMP, 3 PHASE, 2-LEG, 24 TO 120V

Watlow PC20-F30B-0000

185 AMP, 3 PHASE, 2-LEG, 200 TO 480V

PC20-F30C-0000

185 AMP, 3 PHASE, 2-LEG, 200 TO 600V

 

Watlow PC30-F30A-0000

155 AMP, 3 PHASE, 3-LEG, 24 TO 120V

Watlow PC30-F30B-0000

155 AMP, 3 PHASE, 3-LEG, 200 TO 480V

Watlow PC30-F30C-0000

155 AMP, 3 PHASE, 3-LEG, 200 TO 600V

 --------

Watlow PC11-F20A-1000

125 AMP, 1 PHASE, 24 TO 120V

Heater Diagnostics and Communications  

Watlow PC11-F20B-1000

125 AMP, 1 PHASE, 200 TO 480V

Heater Diagnostics and Communications  

Watlow PC11-F20C-1000

125 AMP, 1 PHASE, 200 TO 600V

Heater Diagnostics and Communications  


Watlow PC21-F20A-1000

120 AMP, 3 PHASE, 2-LEG, 24 TO 120V

Heater Diagnostics and Communications  

Watlow PC21-F20B-1000

120 AMP, 3 PHASE, 2-LEG, 200 TO 480V

Heater Diagnostics and Communications  

Watlow PC21-F20C-1000

120 AMP, 3 PHASE, 2-LEG, 200 TO 600V

Heater Diagnostics and Communications  

 

Watlow PC31-F20A-1000

90 AMP, 3 PHASE, 3-LEG, 24 TO 120V

Heater Diagnostics and Communications  

Watlow PC31-F20B-1000

90 AMP, 3 PHASE, 3-LEG, 200 TO 480V

Heater Diagnostics and Communications  

Watlow PC31-F20C-1000

90 AMP, 3 PHASE, 3-LEG, 200 TO 600V

Heater Diagnostics and Communications  

 ------

Watlow  PC11-F25A-1000

200 AMP, 1 PHASE, 24 TO 120V

Heater Diagnostics and Communications  

Watlow PC11-F25B-1000

200 AMP, 1 PHASE, 200 TO 480V

Heater Diagnostics and Communications  

Watlow PC11-F25C-1000

200 AMP, 1 PHASE, 200 TO 600V

Heater Diagnostics and Communications  


Watlow PC20-F25A-1000

160 AMP, 3 PHASE, 2-LEG, 24 TO 120V

Heater Diagnostics and Communications  

Watlow PC21-F25B-1000

160 AMP, 3 PHASE, 2-LEG, 200 TO 480V

Heater Diagnostics and Communications  

Watlow PC21-F20C-1000

160 AMP, 3 PHASE, 2-LEG, 200 TO 600V

Heater Diagnostics and Communications  

 

Watlow PC31-F25A-1000

140 AMP, 3 PHASE, 3-LEG, 24 TO 120V

Heater Diagnostics and Communications  

Watlow PC31-F25B-1000

140 AMP, 3 PHASE, 3-LEG, 200 TO 480V

Heater Diagnostics and Communications  

Watlow PC31-F25C-1000

140 AMP, 3 PHASE, 3-LEG, 200 TO 600V

Heater Diagnostics and Communications  

 ---------

Watlow PC11-F30A-1000

250 AMP, 1 PHASE, 24 TO 120V

Heater Diagnostics and Communications  

Watlow PC11-F30B-1000

250 AMP, 1 PHASE, 200 TO 480V

Heater Diagnostics and Communications  

Watlow PC11-F30C-1000

250 AMP, 1 PHASE, 200 TO 600V

Heater Diagnostics and Communications  


Watlow PC21-F30A-1000

185 AMP, 3 PHASE, 2-LEG, 24 TO 120V

Heater Diagnostics and Communications  

Watlow PC21-F30B-1000

185 AMP, 3 PHASE, 2-LEG, 200 TO 480V

Heater Diagnostics and Communications  

Watlow PC21-F30C-1000

185 AMP, 3 PHASE, 2-LEG, 200 TO 600V

Heater Diagnostics and Communications  

 

Watlow PC31-F30A-1000

155 AMP, 3 PHASE, 3-LEG, 24 TO 120V

Heater Diagnostics and Communications  

Watlow PC31-F30B-1000

155 AMP, 3 PHASE, 3-LEG, 200 TO 480V

Heater Diagnostics and Communications  

Watlow PC31-F30C-1000

155 AMP, 3 PHASE, 3-LEG, 200 TO 600V

Heater Diagnostics and Communications   

 

For a Quote Please use our Watlow Parts Form, HERE!

 

Anderson-Bolds
216-360-9800

Monday, December 14, 2020

Watlow DIN-A-MITE® B SCR Power Controller

Watlow SCR Din-A-Mite Type B Power Controller

from Anderson-Bolds

For a Watlow Din-A-Mite Quote, Click HERE!

Watlow solid state power switching devices complement the rapid switching required by PID temperature controllers and help deliver optimum system performance and service life. They are available in 1-phase and 3-phase/2-leg and 3-leg configurations, feature touch-safe terminations, input indicators, zero-cross, random or phase-angle fire options, ratings from 18 to 1,000 amperes and agency approvals including CE and UL® 508. Various configurations offer short circuit current ratings (SCCR) of 200,000 amperes, extensive system and heater diagnostic capabilities, heater bake out, integrated heat sinks, on-board fuses, RoHS compliance and serial communications.

The Watlow DIN-A-MITE® B is a low-cost, highly compact and versatile solid state electric heat controller. The DIN-A-MITE B capabilities include single-phase and three-phase zero-cross switching up to 40 and 22 amperes, respectively at 600VAC (see rating curve). This electric heat controller's design includes proper heat sinking and terminations simplifying integration into applications. DIN-rail and back panel mounting is standard on this electric heat controller. The Watlow DIN-A-MITE controller is also mercury free.

Variable time base, 4-20mA process control or VAC/VDC input contactor versions are available. A shorted silicon controlled rectifier (SCR) alarm option is also available. All configurations are model number dependent and factory selectable. This power controller also includes 200KA short circuit current rating (SCCR) tested up to480VAC to prevent arch flash with required fusing.

Features include single-phase and three-phase zero cross switching up to 40 and 22 amperes, respectively, at 600VAC (see rating curve). A unique, integrated design removes the guesswork associated with selecting a proper heat sink and adequate terminations for the application.

Watlow Din-A-Mite B SCR Power Controller










Features and Benefits 

200KA SCCR with proper fusing • Minimizes damage in the event of a short circuit 

DIN-Rail and panel mounting • Provides versatility and quick, low-cost installation 

Compact size • Reduces panel space and cost 

Touch-safe terminals • Increases safety for installer and user 

Single and Three-Phase power • Permits use in a variety of applications 

Mercury free • Assures environmental safety 

Faster switching with solid state • Saves energy and extends heater life 

UL® 508 listed, C-UL®, RoHS and CE with filter • Meets applications requiring agency approval • Reduces end product documentation cost 

Back-to-Back SCR design • Ensures a rugged design 

Shorted output alarm (optional) • Simplifies troubleshooting and reduces downtime


Specifications 

Operator Interface • Control input and indication light • Alarm output and indication light 

Amperage RatingSee the output rating curve below• Max. surge current for 16.6ms, 380A peak • Max. I2t for fusing is 4,000A2s • Latching current: 400mA max. • Holding current: 200mA max. • Off-state leakage 1mA at 77°F (25°C) max. • Power dissipation = 1.2 watts per ampere per leg switched • 200KA SCCR, Type 1 and 2 approved with the recommended fusing; see user manual 

Watlow DIN-A-Mite B SCR Amperage (amps) Ratings








Line Voltage • 24 to 660VAC model number dependent; see ordering information 

Control Mode, Zero Cross • Control option C: VDC input, contactor output • Control option K: VAC input, contactor output • To increase service life on contactor models, the cycle time should be less than three seconds • Control option F: 4 to 20mA DC input, variable time-base control output 

Control Input • AC contactor: 24VAC ±10%, 120VAC +10/-25%, 240VAC +10/-25% @ 25mA max. per controlled leg • DC contactor: 4.5 to 32VDC: max. current @ 4.5VDC is 6mA per leg. Add 2mA per LED used to the total current • Linear current: 4 to 20mA DC: loop-powered, control option F0 only (requires current source with 6.2VDC available, no more than three DIN-A-MITE inputs connected in series)

Alarm Shorted SCR Alarm Option • Alarm state when the input command signal off and a 10A or more load current is detected by the current transformer (two turns required for 5A and three turns for 2.5A) Alarm Output • Energizes on alarm, non-latching • Triac 24 to 240VAC, external supply with a current rating of 300mA @ 77°F (25°C), 200mA @ 122°F (50°C), 100mA @ 176°F (80°C) and a holding current of 200 µA with a latching current of 5mA typical

Agency Approvals • CE with proper filter: 204/108/EC Electromagnetic Compatibility Directive EN 61326-1: Industrial Immunity Class A Emissions 2006/95/EC Low Voltage Directive EN 50178 Safety Requirements Installation category III, pollution degree 2 • UL® 508 listed and C-UL® File E73741 • 2011/65/EU RoHS 2 Control Input Terminals • Compression: will accept 24 to 16 AWG (0.2 to 1.5 mm2) wire Line and Load Terminals • Compression: will accept 18 to 8 AWG (0.8 to 8.4 mm2) wire

Operating Environment • See the output rating curve • 0 to 90% RH (relative humidity), non-condensing • Storage temperature: -40 to 185°F (-40 to 85°C) • Operating temperature: -4 to 176°F (-20 to 80°C) • Insulation tested to 3,000 meters DIN-rail Mount • DIN EN 50022, 35 mm by 7.5 mm Back-Panel Mount • Four mounting holes No. 6 to No. 8 (M3 to M4) fastener Dimensions • 3.7 in. (94 mm) high x 3.3 in. (83 mm) wide x 4.9 in. (124 mm) deep • Weight: 1.5 lb (0.68kg)

SCR Controller from Watlow







For a Watlow Din-A-Mite Quote, Click HERE!

Anderson-Bolds


Watlow SCR...Watlow SCR...Watlow SCR...Watlow SCR

Sunday, December 13, 2020

Watlow PM PLUS™ PID & Integrated Limit Controllers

Watlow PM PLUS controllers from Watlow 
and Anderson-Bolds

Watlow’s PM PLUS™, the enhanced EZ-ZONE® PM, is now more intuitive and features an enhanced interface for easier programming and readability with a SMOOTH-TOUCH™ keypad creating an industry leading user experience. The Watlow PM PLUS is backwards compatible with legacy EZ-ZONE PM controllers but offers many user upgrades including an intuitive menu flow allowing the controller to be easily configured. It also continues to offer the industry leading Bluetooth® connectivity with the EZ-LINK™ mobile app for remote access capability and full descriptions of parameters and error codes. The PM PLUS improves the user experience by reducing the complexity at the front of the control while eliminating the dependency of cables when configuring the product.

Like the original Watlow EZ-ZONE PM, the PM PLUS can be ordered as a PID controller, or an integrated controller with multiple functions combined into one. Now Watlow’s PM PLUS is available through Watlow SELECT®, a program that enables you to quickly identify, configure and receive your thermal products faster and easier than ever before. With SELECT, you use a variety of tools to guide your decision, configure products for an exact fit and quickly receive your order. 


For a Watlow PM-PLUS quote, Please click HERE!

Watlow PM-PLUS Temperature Controller










Features and Benefits 

Intuitive menu flow • Reduces menu structure to a list of lists allowing the controller to be easily configured • Offers easy to read characters and color coding making the display visible from many angles 

SMOOTH TOUCH keypad • Eliminates contamination points on the front of the controller • No mechanical components will wear out • Creates a better seal on front panel • Easy to clean

Bluetooth® compatible with EZ-LINK™ mobile app • Provides full descriptions of parameters and error codes • Allows remote access capabilities without the use of cables or converters • Provides the ability to configure the product and save parameter sets 

Integrated PID and limit controller • Reduces wiring time and termination complexity compared with connecting discrete products • Decreases required panel space • Lowers installation costs • Increases user and equipment safety for over/under temperature conditions 

High amperage power control output • Drives 15 ampere resistive loads directly • Reduces component count • Decreases cost of ownership 

Current monitoring • Detects heater current flow and provides alarm indication of a failed output device or heater load • Drives output on open or shorted heater 

Serial communication capabilities • Provides a wide range of protocol choices including Modbus® RTU, EtherNet/IP™, Modbus® TCP, PROFIBUS DP, DeviceNet™ and J1939 CAN bus • Supports network connectivity to a PC or PLC 

Enhanced control options • Easily handles complex process problems such as ratio, differential, square-root, motorized valve control without slidewire feedback, wet-bulb/dry-bulb, compressor control and peltier loads

Countdown timer option • Provides batch process control • Supports set point change during countdown 10-point linearization curve • Improves sensor accuracy 

EZ-LINK™ mobile application for iPhone® and Android™ • Expedites controller setup with intuitive navigation • Simplifies setting parameters with plain text names and descriptions • Connects quickly and easily via Bluetooth® wireless communications 

Configuration communications with software • Includes Watlow standard bus communications used by COMPOSER® or EZ-ZONE configurator software 

Advanced PID control algorithm • Offers TRU-TUNE®+ adaptive control to provide tighter control for demanding applications • Provides auto-tune for fast, efficient start-up 

Built-in sensor compensation curves • Saves cost of buying compensated sensors • Includes Vaisala RH and altitude (pressure) curves 

Remote set point operation • Supports convenient set point manipulation from a remote device such as a master control or PLC 

Profile capability • Offers pre-programmed process control • Allows ramp/soak programming with 40 total steps 

Retransmit output • Supports industry needs for recording 

Factory Mutual (FM) approved over/under limit with auxiliary outputs • Increases user and equipment safety for over/under temperature conditions 

Memory for saving and restoring parameter settings • Decreases service calls and time down 

Agency approvals: UL® listed, CSA, CE, RoHS, W.E.E.E., FM, SEMI F47-0200, Class 1, Div. 2 rating on selected models • Assures prompt product acceptance • Reduces end product documentation costs

Touch-safe package • Increases safety for installer/operator • Complies with IP2X requirements

Programmable function key • Enables simple, one-touch operation of user-defined, repetitive activities 

Programmable menu system • Reduces setup time and increases operator efficiency 

Three-year warranty • Provides product support and reliability

Watlow PM-PLUS Controller 











For a Watlow PM-PLUS quote, Please click HERE!

Specifications:

Controller • User-selectable heat/cool, on-off, P, PI, PD, PID or alarm action • Auto-tune with TRU-TUNE+ adaptive control algorithm • Control sampling rates: input = 10Hz, outputs = 10Hz 

Profile Ramp/Soak • 4 profiles, 40 total steps • Accuracy (typical): ±30 PPM at 77°F (25°C) +30/-100 PPM at -4 to 149°F (-20 to 65°C) 

Isolated Serial Communications • EIA 232/485, Modbus® RTU • EtherNet/IP™/Modbus® TCP • DeviceNet™ • PROFIBUS DP • SAE J1939 CAN bus 

Wiring Termination—Touch-Safe Terminals • Input, power and controller output terminals are touch safe, removable, 12 to 22 AWG 

Universal Input • Thermocouple, grounded or ungrounded sensors greater than 20MΩ input impedance, 3µA open sensor detection, 2kΩ source resistance max. • RTD 2- or 3-wire, platinum, 100Ω and 1000Ω @ 32°F (0°C) calibration to DIN curve (0.00385 Ω/Ω/°C) • Process, 0-20mA @ 100Ω, or 0-10VDC @ 20kΩ, 0-50mV at 20MΩ, 0-1000Ω potentiometer; scalable; inverse scaling 

Functional Operating Range Type J: -346 to 2192°F (-210 to 1200°C) 

Type K: -454 to 2500°F (-270 to 1371°C) 

Type T: -454 to 750°F (-270 to 400°C) 

Type E: -454 to 1832°F (-270 to 1000°C) 

Type N: -454 to 2372°F (-270 to 1300°C) 

Type C: 32 to 4200°F (0 to 2315°C) 

Type D: 32 to 4200°F (0 to 2315°C) 

Type F: 32 to 2449°F (0 to 1343°C) 

Type R: -58 to 3214°F (-50 to 1767°C) 

Type S: -58 to 3214°F (-50 to 1767°C) 

Type B: 32 to 3300°F (0 to 1816°C) 

RTD (DIN): -328 to 1472°F (-200 to 800°C) Process: -1999 to 9999 units 

Accuracy • Calibration accuracy and sensor conformity: ±0.1% of span, ±1°C @ the calibrated ambient temperature and rated line voltage • Types R, S, B; 0.2% • Type T below -50°C; 0.2% • Calibration ambient temperature @ 77°F ±5°F (25°C ±3°C) • Accuracy span: 1000°F (540°C) min. • Temperature stability: ±0.1°F/°F (±0.1°C/°C) rise in ambient max. 

Thermistor Input • 0 to 40kΩ, 0 to 20kΩ, 0 to 10kΩ, 0 to 5kΩ • 2.252kΩ and 10kΩ base at 77°F (25°C) • Linearization curves built-in

Current Transformer Input • Accepts 0-50mA signal (user-programmable range) • Displayed operating range and resolution can be scaled and are user-programmable 

Digital Inputs (DC Voltage) • Max. input: 36V at 3mA • Logic: min. high state 3V at 0.25mA, max. low state 2V 

Digital Inputs (Dry Contact) • Logic: min. open resistance 10kΩ, max. closed resistance 50Ω • Max. short circuit: 20mA 

2 Digital I/O (ordered with power supply option) • Update rate: 10Hz • Input type: user-selectable, dc voltage or dry contact • Output type: switched dc • Output voltage: 24V • Output 5: 24mA max. or drive one 3-pole DIN-A-MITE® • Output 6: 10mA max. 

Output Hardware • Switched dc: 22 to 32VDC @ 30mA max. per single output and 40mA max. total per paired outputs (1 & 2, 3 & 4) 

• Open collector: 30VDC max. @ 100mA max. 

• SSR, Form A, 24 to 240VAC, 1A at 50°F (10°C) to 0.5A at 149°F (65°C) resistive load, 264VAC max., opto-isolated, without contact suppression, 120/240VAC @ 20VA pilot duty 

• Electromechanical relay, Form A, 24 to 240VAC or 30VDC max., 5A resistive load, 100,000 cycles at rated load, 120/240 @ 125VA or 24VAC @ 25VA pilot duty 

• Electromechanical relay, Form C, 24 to 240VAC or 30VDC max., 5A resistive load, 100,000 cycles at rated load, 120/240 @ 125VA or 24VAC @ 25VA pilot duty 

• NO-ARC relay, Form A, 85 to 264VAC, 15A @ 122°F (50°C), resistive load, no VDC, 2,000,000 cycles at rated load 

• Universal process output: range selectable; 0 to 10VDC ±15mV into a min. 1,000Ω load with 2.5mV nominal resolution; 0 to 20mA ±30μA into max. 800Ω load with 5μA nominal resolution; temperature stability 100ppm/°C

Operator Interface • LCD display • SMOOTH TOUCH keypad • Programmable function key

Line Voltage/Power • High voltage option: 85 to 264VAC, 47 to 63Hz • Low voltage option: 20 to 28VAC, +10/-15%; 50/60Hz, ±5% or 12 to 40VDC • Max. power consumption: 10VA (1/32 and 1/16 DIN); 14VA 

Environment • Operating temperature: 0 to 149°F (-18 to 65°C) • Storage temperature: -40 to 185°F (-40 to 85°C) • Relative humidity: 0 to 90% RH, non-condensing 

Agency Approvals • cULus® UL®/EN/CSA C22.2 No 61010-1 Listed, File E185611 • CSA C22.2 No. 24, File 158031 (1/32 and 1/16 DIN sizes) • IP 67, IP 66 front seal • UL® Type 4X front seal indoor locations • cULus® ANSI/ISA 12.12.01-2012, CSA-C22.2 No. 213-1987, Class 1, Div. 2, Groups A, B, C and D, Temperature Code T4A, File E184390 (optional) • FM Class 3545 (limit controls) • CE, RoHS by design, W.E.E.E. • EtherNet/IP™ and DeviceNet™ ODVA Conformance Tested displays

For a Watlow PM-PLUS quote, Please click HERE!

Anderson-Bolds
Cleveland, Ohio
www.anderson-bolds.com
216-360-9800

Thursday, April 30, 2020

FINBAR Tubular Air Heaters

Anderson-Bolds sells Watlow FINBAR Air Heaters

For a quote please use our Watlow Parts Form HERE!

FINBAR™ Single-Ended Heaters

Composed of aluminized steel fins press fitted to a
one-inch single-ended FIREBAR element. The FINBAR™
is designed to improve heat transfer to the air and
permits putting more power in tighter spaces—like forced
air ducts, dryers, ovens and load bank resistors.
Heat transfer, lower sheath temperature and element life
are all maximized by its finned construction. Installation
is simplified by terminations exiting at one end and
mounting accommodations on both ends.

Watlow FINBAR Tubular Finned Air Heater

















Performance Capabilities
• Watt densities up to 50 W/in2 (7.7 W/cm2)
• 304 stainless steel sheath temperatures up to
1200°F (650°C)
• Voltages up to 480VAC
• Amperages up to 48 amperes per heater or
16 amperes per coil

Features and Benefits
Rugged aluminized steel fins
• Provides an increase in surface area to approximately
16 square inches for every linear inch of element
length. Fins press fitted to the heating element
improve heat transfer to the air
Single-ended termination
• Simplifies wiring and installation
Stainless steel mounting bracket, welded to the
terminal end, supplied with a slotted end
• Allows ease of installation
Lavacone seals
• Provides protection against humid storage
conditions, moisture retardant to 221°F (105°C)

Construction Features
Watt Density: Up to 40 W/in2 (6.2 W/cm2)
Fin Surface Area: 16 in2/linear in. (40.5 cm2/linear cm)
Fin Cross Section: 2 x 1 in. (50 x 25 mm)
Maximum Operating Temperature: Sheath material:
304 SS, 1200°F (650°C), fin material; aluminized steel;
1100°F (600°C)
Heater Length: 11 to 120 in. (280 to 3050 mm)
No-Heat Length: 1 in. (25 mm) min.,
12 in. (305 mm) max.
Voltages: Up to 240VAC
Phase: 1-phase parallel or 3-phase wye
Resistance Coils: 1 or 3
Terminations: Flexible lead wires, quick connect
(spade), screw lug (plate) and threaded stud
Seal Material: Lavacone, rated to 221°F (105°C)
Single-End Configuration: Slotted

Typical Applications
• Forced air heating for dryers, ovens, ducts
• Still air heating for ovens, comfort heating
• Incubators
• Ink drying
• Load bank resistors

Application Hints
• Avoid deteriorating the fins by not exceeding the
recommended maximum fin temperature of
1100°F (600°C).
• Ensure proper air flow to prevent premature
heater failure.
• Locate the temperature sensor downstream from
heater(s) for process temperature sensing.
The following mounting parameters are recommended:
• Air flow over element must be parallel with the
flat side.
• Element center line to element center line spacing
must be a minimum of 11/2 in. (38 mm).


Part numbers range from 10.25 inches to 47.75 inches in length.

Wattage range from 300 Watts to 4000 Watts with two watt densities.  
20 W/in2  and  40 W/in2

Watlow FINBAR elements are rated in both 120 volt or 240 volt versions.


For a quote please use our Watlow Parts Form HERE!

Anderson-Bolds
Cleveland, Ohio
216-360-9800

Monday, March 30, 2020

RAYMAX from Watlow

RAYMAX® 1220 and 2030 Panel Heaters from Anderson-Bolds


for a quote please email to watlow@anderson-bolds.com
or use our WATLOW form HERE!

 Ideal For Many Process Heating Applications Requiring “Hot Face” Temperatures

The Raymax Panel heater product line from Watlow solves virtually an application requiring radiant heat from a contamination resistant surfaces to fast responding high temperature needs.

Watlow Raymax Radient Panel


Maximum face temperature up to 2000ºF

Typical applications are:
Thermoforming
Food warming
Paint and epoxy curing
Heat treating
High temperature Furnaces
Tempering and annealing processes




Raymax 1010
1000ºF Face Temperature

The Ryamax 1010 is the ideal for use in screen printing, food warming and other low heat applications. The Heater's "sealed face" keeps contaminates away from the heating element, and the metal surface can be easily wiped or brushed clean whenever needed.
Uniform full surface heat source
Convenient ready to use package
One inch thick backside insulation
Repeatable temperature sensing options
UL: component listing.

Heater width is from 4-20 inches
Heater Length is from 10 to 68 inches
voltage up to 480 vac
Watt Density is 10W/sq. inch
 Easy to install and capable of high surface temperatures,
the RAYMAX® 1220 and 2030 are ideal for many process
heating applications requiring “hot-face” temperatures
above 1000°F (540°C).
Each ceramic fiber heater is mounted in a 212 in. (64 mm)
deep sheet metal case providing thermal insulation. The case
includes post terminals for electrical connections and
provides a mounting system that can be used with virtually
any flat ceramic fiber unit. Watt density and temperature
capabilities can be tailored to meet a specific radiant
application for exposed sinuated embedded coil or foil
element configuration.

Performance Capabilities
RAYMAX 2030 (uses sinuated or coil elements):temperatures up to 2000°F (1095°C); watt densitiesup to 30 W/in2 (4.7 W/cm2)
RAYMAX 1220 (uses an etched foil element):temperatures up to 1200°F (650°C); watt densitiesup to 20 W/in2 (3 W/cm2)
Maximum voltage up to 600V

Features and Benefits
Lightweight, low mass design
Allows fast response to controllers
Self insulation with 21/2 in. (64 mm ) thick mounting case
Provides high efficiency
Thermocouple mounting clamp
Simplifies process system control
Aluminized steel case
Handles temperatures up to 1100°F (595°C)
Special hot-face heating patterns
Designed specifically for an application using an etched foil RAYMAX 1220

Specifications 
Weight: Less than 6.5 lbs/ft2 (31.75 kg/m2
Voltage and Wattage: Ratings, up to 600VAC are based on 
the ceramic fiber heater module mounted in the case. 
Terminals: Terminals are 14-20 threaded studs. Two terminals 
plus ground for single-phase, and three terminals plus ground 
for 3-phase are located on the center length line unless 
otherwise specified. Terminals can be positioned anywhere 
along lines A and B (see illustration below), but not closer 
than 2 in. (51 mm) to the case ends. 
Mounting Legs: Mounting legs are available either 
1 in. (25 mm) or 3 in. (76 mm) length. For made-to-order units, 
mounting legs can be supplied in any incremental length L 
from 12 in. (13 mm) to 3 in. (76 mm). Slots are not provided in 
legs less than 1 in. (25 mm) long. 

Application Hints 
A thermocouple mounting clamp is attached to one end of 
the case, with holes on both ends for alternate locations. 
The clamp can be used with 18 in. (3.2 mm) O.D. sheath 
thermocouples. The clamp is 3/16 in. (4.8 mm) high, but 
can be removed for flush mounting*. 
The maximum recommended surface temperature of the 
heater is based on the rating of the ceramic fiber heater 
module. This can vary from 2000°F (1095°C) at lower watt 
densities, to higher watt densities at reduced surface 
temperatures. Note: maximum wattages cannot be achieved 
at the maximum temperatures simultaneously. 
* 1316 in. (4.8 mm) and 14 in. (6 mm) are available upon request. 

Options 
Several options are available with RAYMAX 1220 and 2030 
models. Contact your Watlow representative for more 
information. 
• Single-phase non-standard location power terminals 
• Terminal box 
• Zoning 
• Mounting studs and legs 
• 3-phase construction 
• Thermocouple mounting tubes 
• Alternate case materials 

RAYMAX 2030 PART NUMBERS
VP504A06T, VP504A12T, VP504A18T, VP504A24T, VP504A30T, VP504A36T
VP506A06T, VP506A12T, VP506A18T, VP506A24T, VP506A30T, VP506A36T
VP508A06T, VP508A12T, VP508A18T, VP508A24T, VP508A30T, VP508A36T
VP510A06T, VP510A12T, VP510A18T, VP510A24T, VP510A30T, VP510A36T
VP510A06T, VP510A12T, VP510A18T, VP510A24T, VP510A30T, VP510A36T
VP512A06T, VP512A12T, VP512A18T, VP512A24T, VP512A30T, VP512A36T
VP514A06T, VP514A12T, VP514A18T, VP514A24T, VP514A30T, VP514A36T
VP516A06T, VP516A12T, VP516A18T, VP516A24T, VP516A30T, VP516A36T


Anderson-Bolds