Wednesday, August 8, 2018

Sure-Foot Prevents Slip and Falls

Anderson-Bolds and Sure-Foot Slip and Fall Prevention


SURE-FOOT Mats and Stair Treads and Tape


How Anti Slip Tape Keeps Workers Safe in the Oil & Gas Industry

Oil and gas is one of the fastest growing labor sectors, and with growth comes more liability.
2017 report showed the oil and gas industry has one of the highest rates of severe injury. With the sector’s constant growth, these injuries will continue to plague workers and cause slowed production, excess time off, long-term disability or even death.
You cannot eliminate the uncertainty surrounding labor-intensive jobs like those in the oil and gas industry but knowing about environmental hazards can help mitigate some of the dangers that lead to critical error and injury.
Sure-Foot Stair Treads

Sure-Foot Anti-Slip Tape
Slips, Trips, and Falls
Like so many other industries, prominent workplace hazard in the oil and gas industry lead to a slip, trip, or fall.
According to Occupational Safety and Health Administration (OHSA), most general industry accidents happen due to slips, trips, and falls. They also cause 15% of accidental workplace fatalities, second only to motor vehicles.
Slips, trips, and falls don’t just impact the worker, but they constitute a considerable amount of workers’ compensation and medical bills, over $70 billion yearly in the U.S., according to the National Safety Council.
Environments vary, but whether a workplace is involved in discovering, producing, obtaining, refining or distributing oil or gas, the ground can become slick from various liquids.
The combination of oil and water on steel surfaces can be a recipe for disaster for workers hustling through high traffic areas.
While metal products in these types of environments are often covered in slip resistant coatings, these coatings can quickly wear away in a short time when exposed to the harsh conditions of the oil and gas industry like offshore fracking sites.
Another issue that must be considered in these environments is exposure to diverse elements that can cause metal platforms to both rust and corrode. Things like salt water will only further the chance of equipment breakdowns and workplace injury.
Companies should invest in a well-planned strategy for workplace safety to combat these continuously dangerous situations.
Products like Sure-Foot’s anti-slip tapes are an excellent addition to surfaces that see heavy traffic or areas that are prone to accumulating moisture. For environments with extreme heat, cold, ocean exposure, increased foot traffic or other more strenuous factors, Master Stop EXTREME Tapes offers added adhesion and anti-slip safety.
Sure-Foot is also known for its fiberglass products, including step covers and walkway applications as well as product customization. Sure-Foot creates products that fit specifications for each customer, helping to increase and promote safety.

Vehicle Accidents

Accidents and incidents involving work vehicles continue to be a significant portion of workplace injury in the oil and gas industry.
For example, a vehicle could be driven to pipelines or pumping stations. Others could transport oil and gas. In addition, workers could be struck by work vehicles or machinery.
Many of these incidents can be attributed to carelessness due to employee fatigue. Long shifts, physically challenging work, and overexertion can lead to reduced awareness of workers.
Having safety signs, protective barriers and the proper warning labels on machinery can help to minimize these incidents. Adequate training for employees working with this equipment will make them more aware of the dangers they encounter in the workplace.
Injuries in the oil and gas industry will never be entirely preventable. But they can be limited with the proper safety planning, procedures, and safety products. Buy Sure-Foot to be sure!

Anderson-Bolds
216-360-9800
www.anderson-bolds.com

Thursday, July 26, 2018

Littelfuse Off Delay Adjustable Timer TDBL12D

Anderson-Bolds has in stock the Littelfuse Adjustable TDR working on 12vdc.  The TDBL12D can be shipped within 24 hours of an order.

LittelFuse SSAC TDR TDBL12D, with a .1-102.3 Second Adjustable Range. 10 amp rating and 12 volts DC (Octal Socket required). The Timer is an Delay-On-Break (Off Delay) time delay relay. The Time Delay Relay is now made by Little Fuse. UL, CSA and CE. Previous manufacturers were SSAC, Entrelac, ABB and Sycom. Littelfuse part number is TDBL12D

Buy the Timer/TDR HERE!



TBDL12D 


















Anderson-Bolds
216-360-9800
www.anderson-bolds.com

Monday, July 16, 2018

Parker's NEW G7 Solenoid Valves

New G7 valves from Parker and Anderson-Bolds


Parker's new generation of G7 solenoid valves delivers the confidence to get the toughest jobs done right. And thanks to advanced Parker technologies, success has never been easier. Ensuring high performance and an optimized total cost of ownership, Parker continues to focus on Engineering Your Success.

Call Anderson-Bolds for a quote.  216-360-9800
or email at sales@anderson-bolds.com














Markets 
Commercial Equipment 
Food & Beverage 
Industrial Automation 
Oil & Gas 
Process Control 

Specifications 
• Port Sizes: 1/8" - 3/8" NPT • Pressures: Up to 2200 psi • Flows: Up to 1.06 Cv 

Benefits 

Industry-Leading Performance 

High Pressures 
High Flows 
High Temperatures 
Corrosion Resistant 
Environmentally Resistant 

Premium Construction 
• 303 Stainless Steel • Lead-Free Brass* • IP67, Thermal Shock-Resistant Solenoid Coil • Engineered for Long Life • Proven Gold Ringand Skinner® Fundamentals 

Ease of Doing Business 
• 24-Hour Express Ship Program • Innovative Parker Tracking System (PTS) • Easy-Install Conduit Solenoid Coil • Simplified Installation and Service • Durable Laser-Marked Identification • Domestic Manufacturing and Support 

2-Way Normally Closed, Direct Acting - Stainless Steel  AC voltage
2-Way Normally Closed, Direct Acting - Stainless Steel  DC Voltage
2-Way Normally Closed, Direct Acting - Brass AC Voltage
2-Way Normally Closed, Direct Acting - Brass DC Voltage
2-Way Normally Open PIBOS*, Direct Acting - Stainless Steel 
* PIBOS (Pressure In Body, Out Sleeve): An economical approach to 2-Way Normally Open valves. 
   Pressure enters body, exits through sleeve on top of valve. 

PARKER G7 available COILS are :
C7F 120/60 with 1/2 NPT conduit, IP67, Nema 6
C7G 240/60 with 1/2 NPT conduit, IP67, Nema 6
C7E  24/60 with 1/2 NPT conduit, IP67, Nema 6

D7F 120/60  DIN Style, IP65, Nema 4X
D7G 240/60 DIN Style, IP65, Nema 4X
D7E  24/60  DIN Style, IP65, Nema 4X

B7F 120/60 with simple 18 inch leads, IP67, Nema 6
B7G 240/60 with simple 18 inch leads, IP67, Nema 6
B7E  24/60 with simple 18 inch leads, IP67, Nema 6

C7A  12VDC with 1/2 NPT conduit, IP67, Nema 6
C7B  24VDC with 1/2 NPT conduit, IP67, Nema 6

D7A  12VDC DIN Style, IP65, Nema 4X
D7B  24VDC DIN Style, IP65, Nema 4X

B7A  12VDC with simple 18 inch leads, IP67, Nema 6
B7B  24VDC with simple 18 inch leads, IP67, Nema 6

STAINLESS STEEL BASE VALVE PART NUMBERS ARE:
                         AC VOLTS    DC VOLTS
20CC02GV7   750 PSI          500 PSI
20CC02PV7    375 PSI          145 PSI
20CC02QV7    230 PSI          85 PSI
20CC04GP7    750 PSI          500 PSI
20CC04LV7     550 PSI          260 PSI
20CC04PV7    375  PSI          145 PSI
20CC04QV7    230 PSI            85 PSI
20CC04TV7     110 PSI            40 PSI
20CC041V7     40 PSI              20 PSI

BRASS BASE VALVE PART NUMBERS ARE:
20LC02PN7     375 PSI          145 PSI 
20LC02QN7     230 PSI          85 PSI 
20LC04GN7     750 PSI          500 PSI 
20LC04PN7      375 PSI          145 PSI  
20LC04QN7      230 PSI          85 PSI
20LC04TN7      110 PSI            40 PSI 
 20LC041V7       40 PSI              20 PSI

Call Anderson-Bolds for a quote.  216-360-9800

ANDERSON-BOLDS 
BEACHWOOD, OHIO

Wednesday, July 4, 2018

SSAC/Littelfuse Voltage Monitor HLMUDLAAA

Voltage Monitor Protection Relay HLMUDLAAA from Anderson-Bolds
Made by Littelfuse

Contact Anderson-Bolds

LittelFuse SSAC Voltage Monitor HLMUDLAAA is a universal voltage monitor. 10 amp output relay rating. The HLM Voltage Monitor senses over or under voltage AND phase unbalance and frequency fluctuations and trips if any go oout of range. The Voltage Monitors are currently made by Little Fuse. UL, CSA and CE. Previous manufacturers were SSAC, Entrelac, ABB and Sycom.

BUY the HLMUDLAAA


The HLMU Series is a universal voltage, encapsulated, 3-phase voltage monitor. It continuously measures the voltage of each of the three phases with microcontroller accuracy and compares the value to preset trip points. It separately senses phase reversal and loss; over, under and unbalanced voltages; and
over or under frequency. Protection is assured during periods of large average voltage fluctuations, or when regenerated voltages are present. The unit trips within 200ms when phase loss is detected. Adjustable time delays are included to prevent nuisance tripping and short cycling of sensitive equipment. The isolated, 10A, DPDT relay contacts trip when a phase voltage exceeds the trip limits for the trip delay. Nominal line voltage, voltage unbalance, and time delays are knob adjustable. The phase loss setpoint and the acceptable frequency range are fixed. Both delta and wye systems can be monitored; no connection to neutral is required.


Voltage Monitor HLMUDLAAA


BENEFITS
Constant monitoring to protect against phase loss, phase reversal; over, under, and unbalanced voltage; over and under frequency
Flexibility to work in 200 to 480VAC applications
Installation flexibility
Provides diagnostics of relay, fault and time delay status
Protects against shock, vibration, and humidity Meets IEC 61000 safety requirements

Operation
Upon application of line voltage, the output is de-energized
and the restart delay begins. If all the three-phase voltages are within the acceptable range, the output energizes at the end
of the restart delay. The microcontroller circuitry automatically senses the voltage range, and selects the correct operating frequency (50 or 60Hz). The over and under voltage trip points are set at ± 10% of the adjusted line voltage. When the measured value of any phase voltage exceeds the acceptable range limits (lower or upper) the trip delay begins. At the end of the trip delay the output relay de-energizes. If the phase voltage returns to an acceptable value before the trip delay expires, the trip delay is reset and the output remains energized. Under, over, and unbalanced voltages plus over or under frequency must be sensed for the complete trip delay before the unit trips. The unit trips in 200ms when phase loss or reversal are sensed. The unit will not energize if a fault is sensed as the line voltage is applied. 


Reset: Reset is automatic upon correction of the voltage or frequency fault or phase sequence.


Restart Delay Options
L = Lockout or minimum OFF time. The restart delay begins when the output trips. The unit cannot be re-energized until the restart delay is complete. This provides a minimum off time
or lockout time to allow equipment sensitive to short cycling, time to reset. If the fault is corrected after the restart delay is complete, the output energizes immediately. The restart delay also occurs when line voltage is applied/reapplied.
R = Restart Delay on fault correction. The restart delay begins when line voltage is reapplied or when a voltage fault is corrected. This option is normally selected when staggered restarting of multiple motors on a power system is required.
N = No Restart Delay. 0.6 second initialization delay on application of line voltage applies.
Restart Notes: All restart options remain reset when the following conditions are detected:
1. Phase loss (phase unbalance greater than 25%) 2. Average line voltage less than 120VAC
3. Phase reversal

The restart delay begins when the condition is corrected.


LED Operation
The LED flashes green during the restart delay, then glows green when the output energizes. It flashes red during the trip delay then glows red when the output de-energizes. It flashes red/green if phase reversal is sensed. If a fault is sensed during the restart delay, the LED will glow red during that portion or the full restart delay. 


Type

3-phase delta or wye with no connection to neutral


Range
240 380 480
Voltage Adj. Range
200-240VAC 340-420VAC 400-480VAC
Frequency
50 or 60Hz 50Hz 60Hz

Line Voltage Max.
550VAC
AC Line Frequency
50/60 Hz automatically detected
Phase Loss
≥ 25% unbalance
Response Time
≤200ms 

Overvoltage Trip Voltage 
109 - 113% of the adjusted line voltage
 Reset Voltage
-3% of the trip voltage

Undervoltage Trip Voltage
88 - 92% of the adjusted line voltage
Reset Voltage
+3% of the trip voltage 

Voltage Unbalance Trip Setpoint
Adjustable 2 - 10% or specify fixed unbalance of 2 - 10% in 1% increments
Reset on Balance
-0.7% unbalance
Trip Delay Active On
Over/under voltage, voltage unbalance, over/under frequency

Range
Adjustable from 1 - 30s or specify fixed delay 1 - 30s in 1s increments
Tolerance
±15%
Restart Delay Range
Adjustable from 0.6 - 300s; if no restart delay is selected a 0.6s initialization delay applies 

Tolerance


±15%
Over/Under Frequency
±4%; Reset ±3%; 50/60 Hz
Phase Sequence
A, B, C, L1, L2, L3
Response Time-Phase
Reversal & Phase Loss
≤200 ms
Reset
Automatic

Output 

Isolated Electromechanical Relay


DPDT


10A resistive @ 240VAC;
8A resistive @ 277VAC; NO-1/4 hp @ 120VAC; 1/3 hp @ 240VAC

Protection
Phase Reversal/Failure

ASME A17.1 Rule 210.6
Motors and Generators
NEMA MG1 14:30, 14:35
Surge
IEEE C62.41-1991 Level B
Isolation Voltage
≥ 2500V RMS input to output
Circuitry
Encapsulated

Dimensions
H 76.7 mm (3.0”); W 50.8 mm (2.0”);
D 41.7 mm (1.64”)

Termination
Screw terminal connection up to 12 AWG (3.3 mm2) wire
  
 Temperature
 -40° to 60°C / -40° to 85°C

BUY the HLMUDLAAA
www.anderson-bolds.com
Anderson-Bolds
216-360-9800

Saturday, June 16, 2018

Sure-Foot Stair Treads - Bold Step

Stair Treads and Grit Tape from Sure-Foot and Anderson-Bolds

Buy Sure-Foot Treads on Anderson-Bolds HERE.

Bold Step is an eye catching resilient anti-slip stair Tread for areas where slipping can be dangerous. Either used on new construction or renovation projects, Sure-Foot delivers maximum safety and durability while providing a loo to compliment toddy's building designs.  Bold Step is strong enough for industrial applications but attractive enough for residences.

Sure-Foot 3 inch covers
Bold Step Stair Treads

Industry Leading Technology
Exceeds OSHA and ADA Requirements
Corrosive Resistant Extruded Aluminum
Abrasive Closed Cell Epoxy Filler
Easy to Install and Maitain

Bold Step Coating system resists chips, dirt, scratches, stains, and oils unlike open cell porous products.  Periodic washing is all it takes to keep the steps looking new.

Sure-Foot is MADE in the USA.

Sure-Foot Helps recent Slip and Falls.

Sure-Foot Tread, Yellow/Black, 9 inch depth and 36 inch length, Aluminum
Part Number 409NS20036102

Sure-Foot Tread, Yellow/Black, 9 inch depth and 48 inch length, Aluminum
Part Number 409NS20048102

Sure-Foot Tread, Yellow/Black, 11 inch depth and 36 inch length, Aluminum
Part Number 411NS20036102

Sure-Foot Tread, Yellow/Black, 11 inch depth and 48 inch length, Aluminum
Part Number 411NS20048102




Sure-Step Industries
Anderson-Bolds
Contact us HERE












Thursday, May 31, 2018

SSAC Flasher FS152

Littelfuse FS152 Flasher from ANDERSON-BOLDS

The Littelfuse Flasher 152 runs on 120 volts and has 90 Flashes per Minute (FPM) rate.


The FS100 Series (medium power) may be used to control inductive, incandescent, or resistive loads. Input voltages of 24, 120, or 230VAC are available. Fixed flash rates in stock range from 30, 50, 60, and 90 FPM, with custom flash rates ranging from 10 to 300 FPM. Encapsulation provides protection against shock, vibration, and humidity. This group of solid-state flashers has proven reliability with years of use throughout the world.
Operation
Upon application of input voltage, the T2 OFF time begins. At the end of the OFF time, the T1 ON time begins and the load energizes. At the end of T1, T2 begins and the load de-energizes. This cycle repeats until input voltage is removed. 

SSAC/Littel Fuse FS 152 Flasher













Anderson-Bolds
www.anderson-bolds.com
216-360-9800

Tuesday, March 27, 2018

Jefferson Solenoid Valves

Anderson-Bolds is your 
Jefferson Valve source

Contact Anderson-Bolds HERE



Jefferson Valves General Purpose Solenoid Valves






















Jefferson Valves are now lead free for potable drinking water applications.

Sizes range from 1/8 inch to 3 inch in 2-way, 3-way and 4-way valves.



Anderson-Bolds
216-360-9800