Friday, May 28, 2021

Southwire TRC 30 Amp GFCIs with Twist Lock Plugs

Southwire  TRC series 44700 and 44720 30 amp GFCIs 

See all of our ground fault circuit interrupters HERE!

30 amp GFCI IN-LINE Cord Sets with Manual Reset.

TRC 30 Amp GFCI's
44700 004-3, 44700 005-2
44720 012-3,  44720 013-2, 44720 020-1
 















Designed for rugged duty. Molded from high impact polymer with booted reset and test buttons. At home in hostile environments such as industrial, construction, maintenance and commercial work sites. Provides compliance with National Electric Code (NEC 2008) Article 590.6 for “Temporary Installations.” Rainproof rated, UL listed for outdoor use. Standard lengths:
2’, 6’, and 25’ with corresponding locking connectors. Custom cable gauges, lengths and terminations available by special order. To prevent unmonitored equipment startup, manual reset is required after GFCI trip and power outage.

44700 004-3 (2’)
44700 005-2 (6’)
• Volts/Amps: 120V/30A • Cord Gauge: 10/3 AWG • NEMA L5-30P & R
• Trip Level: 4 - 6 mA

Southwire's Technology Research Corporation (TRC) GFCI Inline Cord Sets 44700 (120V/30 A)  44720 (240V/30 A) are designed for rugged duty.  Plug and Receptacles are molded from high impact polymer with booted reset and test buttons.  The TRC 44700/44720 series are at home in hostile environments such as industrial, construction, maintenance and commercial work sites. Cord Gauge is 10/3 AWG for maximum strength and durability. Ideal for use by contractors and industrial maintenance personnel working with extension cords or portable tools.  Provides compliance with National Electric Code (NEC 2008) Article 590.6 for Temporary Installations. Applications include: High Pressure Sprayer Washers, Power Tools, Drain Snakes, Pumps, Construction Sites, Industrial Appliances. The TRC GFCI is Rainproof rated, UL listed for outdoor use.  Cord lengths are 2, 6 and 25 feet. The 120 version does not have a 25' length, only 2' and 6'.Voltage rating are 120 and 240 vac, amperage rating is 30, trip level is 4-6mA and has standard 120 or  240 volt NEMA L5 or L6-30 Black Plug & Receptacle. To prevent unmonitored equipment startup, manual reset is required after GFCI trips and power outages or when you unplug and plug back in.

44720 012-3 (3’)
44720 013-2 (6’)
44720 020-1 (25’)
• Volts/Amps: 240V/30A • Cord Gauge: 10/3 AWG • NEMA L6-30P & R

• Trip Level: 4 - 6 mA 

APPLICATIONS INCLUDE 

• High Pressure Sprayer Washers 

• Construction Site Power Tools 

• Drain Snakes

• Pumps

• Industrial Appliances 

• Construction Sites

GROUNDED NEUTRAL   

4 Ohms

TRIP RESPONSE TIME FOR GROUND FAULT 

AND GROUNDED NEUTRAL TRIP  

Less Than 25mS

VOLTAGE SURGE WITHSTAND     

3kv ringwave test and 4kv/2kA surge immunity test

RADIO FREQUENCY NOISE SUSCEPTIBILITY   

Operates Within Normal Limits With 0.5 Volts 

Injected On Power Line 150Khz-230Mhz

FREQUENCY   

60 Hz

ENDURANCE   

3,000 Operations Minimum

OVERLOAD CURRENT   

Six Times Rated Current

OPERATING TEMPERATURE RANGE  

 -35 ̊C to 66 ̊C

EFFECT OF 10 AMP TURN DC SHOCK FAULT TRIP     

5% Maximum Trip Level Variation on Ground 

INSULATION VOLTAGE   

1500 Vrms - 1 Min.

POWER ON INDICATION    

Lighted Indicator 


Anderson-Bolds sells TRC Ground Fault Circuit Interrupters 


Southwire TRC 120 volt 30 amp GFCIs

44700 004-3 (2’)
44700 005-2 (6’)

Southwire TRC 240 volt 30 amp GFCIs

44720 012-3 (3’)
44720 013-2 (6’)
44720 020-1 (25’)


Anderson-Bolds


GFCI...GFCI...GFCI...GFCI...GFCI

Wednesday, August 8, 2018

Sure-Foot Prevents Slip and Falls

Anderson-Bolds and Sure-Foot Slip and Fall Prevention


SURE-FOOT Mats and Stair Treads and Tape


How Anti Slip Tape Keeps Workers Safe in the Oil & Gas Industry

Oil and gas is one of the fastest growing labor sectors, and with growth comes more liability.
A 2017 report showed the oil and gas industry has one of the highest rates of severe injury. With the sector’s constant growth, these injuries will continue to plague workers and cause slowed production, excess time off, long-term disability or even death.
You cannot eliminate the uncertainty surrounding labor-intensive jobs like those in the oil and gas industry but knowing about environmental hazards can help mitigate some of the dangers that lead to critical error and injury.
Sure-Foot Stair Treads

Sure-Foot Anti-Slip Tape
Slips, Trips, and Falls
Like so many other industries, prominent workplace hazard in the oil and gas industry lead to a slip, trip, or fall.
According to Occupational Safety and Health Administration (OHSA), most general industry accidents happen due to slips, trips, and falls. They also cause 15% of accidental workplace fatalities, second only to motor vehicles.
Slips, trips, and falls don’t just impact the worker, but they constitute a considerable amount of workers’ compensation and medical bills, over $70 billion yearly in the U.S., according to the National Safety Council.
Environments vary, but whether a workplace is involved in discovering, producing, obtaining, refining or distributing oil or gas, the ground can become slick from various liquids.
The combination of oil and water on steel surfaces can be a recipe for disaster for workers hustling through high traffic areas.
While metal products in these types of environments are often covered in slip resistant coatings, these coatings can quickly wear away in a short time when exposed to the harsh conditions of the oil and gas industry like offshore fracking sites.
Another issue that must be considered in these environments is exposure to diverse elements that can cause metal platforms to both rust and corrode. Things like salt water will only further the chance of equipment breakdowns and workplace injury.
Companies should invest in a well-planned strategy for workplace safety to combat these continuously dangerous situations.
Products like Sure-Foot’s anti-slip tapes are an excellent addition to surfaces that see heavy traffic or areas that are prone to accumulating moisture. For environments with extreme heat, cold, ocean exposure, increased foot traffic or other more strenuous factors, Master Stop EXTREME Tapes offers added adhesion and anti-slip safety.
Sure-Foot is also known for its fiberglass products, including step covers and walkway applications as well as product customization. Sure-Foot creates products that fit specifications for each customer, helping to increase and promote safety.

Vehicle Accidents

Accidents and incidents involving work vehicles continue to be a significant portion of workplace injury in the oil and gas industry.
For example, a vehicle could be driven to pipelines or pumping stations. Others could transport oil and gas. In addition, workers could be struck by work vehicles or machinery.
Many of these incidents can be attributed to carelessness due to employee fatigue. Long shifts, physically challenging work, and overexertion can lead to reduced awareness of workers.
Having safety signs, protective barriers and the proper warning labels on machinery can help to minimize these incidents. Adequate training for employees working with this equipment will make them more aware of the dangers they encounter in the workplace.
Injuries in the oil and gas industry will never be entirely preventable. But they can be limited with the proper safety planning, procedures, and safety products. Buy Sure-Foot to be sure!

Anderson-Bolds
216-360-9800
www.anderson-bolds.com

Saturday, June 16, 2018

Sure-Foot Stair Treads - Bold Step

Stair Treads and Grit Tape from Sure-Foot and Anderson-Bolds

Buy Sure-Foot Treads on Anderson-Bolds HERE.

Bold Step is an eye catching resilient anti-slip stair Tread for areas where slipping can be dangerous. Either used on new construction or renovation projects, Sure-Foot delivers maximum safety and durability while providing a loo to compliment toddy's building designs.  Bold Step is strong enough for industrial applications but attractive enough for residences.

Sure-Foot 3 inch covers
Bold Step Stair Treads

Industry Leading Technology
Exceeds OSHA and ADA Requirements
Corrosive Resistant Extruded Aluminum
Abrasive Closed Cell Epoxy Filler
Easy to Install and Maitain

Bold Step Coating system resists chips, dirt, scratches, stains, and oils unlike open cell porous products.  Periodic washing is all it takes to keep the steps looking new.

Sure-Foot is MADE in the USA.

Sure-Foot Helps recent Slip and Falls.

Sure-Foot Tread, Yellow/Black, 9 inch depth and 36 inch length, Aluminum
Part Number 409NS20036102

Sure-Foot Tread, Yellow/Black, 9 inch depth and 48 inch length, Aluminum
Part Number 409NS20048102

Sure-Foot Tread, Yellow/Black, 11 inch depth and 36 inch length, Aluminum
Part Number 411NS20036102

Sure-Foot Tread, Yellow/Black, 11 inch depth and 48 inch length, Aluminum
Part Number 411NS20048102




Sure-Step Industries
Anderson-Bolds
Contact us HERE












Saturday, April 30, 2016

TRC Southwire High Power 100 Amp GFCI - ELCI

Anderson-Bolds sells TRC / Southwire GFCI's and ELCI's up to 100 AMPS.

These are the  new Southwire TRC 24736-001 and 24994-001 100 amp 6-10-30 Trip Level GFCI and ELCI Units.

Anderson-Bolds is your source for Commercial safety products including GFCIs and ELCIs.

GFCIs and ELCIs are used for personnel and equipment protection.


TRC has engineered a new option for the HD-PROTM series called 6.10.30TM.
Configured for both in-line and bulk head mount. This unique new design allows the user to select and lock in the most sensitive trip level at which a specific type of equipment can be operated without nuisance tripping. Adjustable settings
include trip levels for 6mA, 10mA and 30mA. Trip level flexibility to meet your needs in one single device - HD-PROTM with 6.10.30TM.  6.10.30TM key enables trip level selection and locking at a trip level with key removal.  

The GFCIs protect Motors, Pumps, Pressure Washers, Conveyors, Welders and lifts.

Go To GFCI/ELCI Store Page HERE. or call 216-360-9800


TRC 24736-001 and TRC 24994-001
100 amp GFCI/ELCI





















Specifications:

Voltage:  480 or 600 volts AC and three phase
AMPS: 100
Cord Gauge: 2/4 AWG
Trip Levels: 6mA, 10mA, 30mA - chosen by Key Switch
GFCI Response Time: 25mS
Frequency: 50/60 Hz
Endurance: 3,000 operations minimum
Overload Current: SIX times rated current
Temperature Range: -20C to +40C
Power n Indicator: Light
Drop Out Voltage: About 60% rated voltage
Reset Type: Auto
Connection: Flying Leads
Enclosure: NEMA 4 Polymer



216-360-9800
www.anderson-bolds.com





Friday, November 8, 2013

Grieve Class A Ovens for Solvents/Vapors

Grieve Oven Corporation makes Class A Bench Ovens - Anderson-Bolds

CLASS A ovens are ovens for processing applications that involve solvents and vapors that are harmful to workers.

Grieve Model NBS Bench Oven(see below)


OSHA requires ovens processing flammable solvents or vapors to conform to the National Fire Protection Association Standard 86 (1999). NFPA 86 defines ovens for these applications as Class A ovens. In order to keep flammable vapor concentration at safe levels, Class A ovens include specific items of additional equipment to provide safety ventilation. This additional equipment is sized based on the volume of solvent being evaporated and the maximum operating temperature.
Safety ventilation also depends on the processing method. In batch processes, where all parts heat up at the same time, the flammable vapor concentration in not constant. As the work temperature rises the vapor concentration also rises to a peak value and then tapers off. This requires greater safety ventilation than in continuous processing where parts are heated sequentially and the vapor concentration remains constant.
Direct - fired gas ovens include Class A equipment to remove products of combustion. Combustion venting is sized at 183 standard cubic feet per minute of exhaust per 1,000,000 BTU/HR of burner rating. Depending on the amount of flammable solvent processed, a larger powered forced exhauster may be required to handle both combustion venting and safety ventilation.

  


SIZING SAFETY VENTILATION AND HEAT LOSS

Safety ventilation exhaust provides a supply of fresh air to ensure that the flammable vapor concentration in the oven remains below the Lower Flammable Limit (LFL) at all times. When more than one flammable solvent is present, safety ventilation is based on the solvent requiring the greatest amount of ventilation
Direct-fired gas heated ovens require combustion venting which must be added to the safety ventilation exhaust rate.
Combustible solids or substrates do not require safety ventilation unless flammable constituents are released when these materials are heated. Powder coating curing ovens require safety ventilation to be calculated as though 9 % of the powder weight is being evaporated as the flammable solvent Xylene.
Exhaust rates must be corrected for maximum operating temperature. As oven operating temperature increases, greater exhaust is required to compensate for the decrease in air density. Similarly, at altitudes over 1000 feet, the exhaust rate must be increased to compensate for lower air density.

• Batch Processing

For batch oven applications below 250° F, the safety ventilation exhaust rate must be sized at a rate of 440 standard cubic feet per minute for each gallon of solvent introduced into the oven in a batch. Between 250° F and 500° F, this exhaust rate must be increased by a multiplier of 1.4. Above 500° F, the 1.4 multiplier is not appropriate and a correction factor must be determined by tests run by the solvent manufacturer.
In addition, for solvents where the volume of air necessary to render 1 gallon of solvent barely explosive exceeds 2640 standard cubic feet, the exhaust rate must be increased. The increase is made by multiplying by a factor created by taking the volume of air necessary to render 1 gallon of solvent barley explosive and dividing it by 2640 standard cubic feet.
Safety ventilation and heat loss for a batch process can be estimated using the chart below. This chart shows the exhaust rate and heat loss for 0.1 gallon of solvent. The data is based on a solvent with LFL of 2640 standard cubic feet and on an installation located below 1000 feet in altitude.



• Continuous Processing

For continuous processing ovens, the safety ventilation exhaust rate must be sized to keep the concentration of solvent in the oven atmosphere below 25% of the Lower Flammable Limit (LFL) after the LFL has been corrected for operating temperature.
The specific gravity and vapor density of the solvent are used to determine the gallons of vapor created by 1 gallon of evaporated solvent. Combining this information with the Lower Flammable Limit determines the air volume rendered barely explosive when 1 gallon of solvent is evaporated. This is multiplied by a factor of 4 to limit the vapor concentration to 25% of the Lower Flammable Limit.

The safety ventilation exhaust rate is obtained by multiplying this volume by the number of gallons of solvent evaporated per minute.


Safety ventilation and heat loss for a continuous process can be estimated using the chart below. This chart shows the exhaust rate and heat loss for 0.1 gallon of Xylene. Xylene has specific gravity of 0.88 (Water = 1) and vapor density of 3.7 (Air = 1). The Lower Flammable Limit by volume is 0.9%. The amount of air rendered barely explosive per gallon evaporated is 2899 standard cubic feet. The calculated exhaust required per gallon of Xylene evaporated in continuous processing is 193 standard cubic feet per minute.

GRIEVE MODEL NBS Class A Bench Oven  (Picture Above)

Model NBS-400 meets the requirements of OSHA and National Fire Protection Association Standard 86 for Class A ovens. Not for use in hazardous locations as defined in the National Electric Code.
These rugged bench ovens are designed for a wide variety of industrial heat processing applications including those where flammable solvents or vapors will be present in the oven.
Fan forced recirculation of heated air throughout 7 cubic foot work space at temperatures to 400°F. Includes two (2) removable nickel plated wire shelves easily adjustable on 2" centers. Holds a maximum of seven (7) shelves. Includes safety equipment required when flammable solvents or vapors are present in an oven. 
STANDARD FEATURES
— Recirculating blower
— 304 stainless steel interior
— Incoloy sheathed tubular heating elements
— Silicone rubber door gasket
— Analog, thermocouple actuated, temperature controller
— Adjustable, thermocouple actuated, manual reset excess
     temperature interlock
— On-off switch
— Red pilot light indicates heater operation
— Sturdy steel construction
— Brushed stainless steel exterior
— 6 lb/cf density industrial rockwool insulation
— Built-in baffles prevent radiant heat
— Fully factory tested
— 1 year limited warranty
• Standard Electrical Characteristics
— 208 volts, 1-phase, 60 Hz
— 230 volts, 1-phase, 60 Hz
— Other electrical characteristics available
Completely wired control panel assembled on the oven enclosing the temperature controller, manual reset excess temperature interlock, pilot light to indicate when heaters are energized and on-off switch. Includes additional safety equipment required by OSHA and NFPA 86 for Class A ovens. Will handle a maximum of 3 ounces (0.024 gallons) of flammable solvents or vapors per batch at a maximum temperature of 400°F. 

• Manual Reset Excess Temperature Interlock
Turns off heat if oven exceeds 400°F.

• Back-Up Heating Element Relay
Turns off oven heat on excess temperature controller actuation in the
event of failure of the primary heating element relay

• 35 CFM Separately Powered Forced Exhauster
Provides safety ventilation. Exhaust outlet 4" diameter.

• Exhauster Air Flow Safety Switch
Turns off oven heat if exhauster fails

• Recirculating Blower Air Flow Safety Switch
Turns off oven heat if recirculating blower fails

• Purge Timer
Provides time delay to allow exhauster to pull four oven volumes of
air through the oven prior to turning oven heat on



216-360-9800 / 614-885-3933 / 513-528-5680
grieve@anderson-bolds.com


Cleveland - Cincinnati - Columbus
Ohio - West Virginia - Kentucky