Southwire TRC 30 Amp GFCIs with Twist Lock Plugs

Southwire  TRC series 44700 and 44720 30 amp GFCIs 

See all of our ground fault circuit interrupters HERE!

30 amp GFCI IN-LINE Cord Sets with Manual Reset.

TRC 30 Amp GFCI's
44700 004-3, 44700 005-2
44720 012-3,  44720 013-2, 44720 020-1
 















Designed for rugged duty. Molded from high impact polymer with booted reset and test buttons. At home in hostile environments such as industrial, construction, maintenance and commercial work sites. Provides compliance with National Electric Code (NEC 2008) Article 590.6 for “Temporary Installations.” Rainproof rated, UL listed for outdoor use. Standard lengths:
2’, 6’, and 25’ with corresponding locking connectors. Custom cable gauges, lengths and terminations available by special order. To prevent unmonitored equipment startup, manual reset is required after GFCI trip and power outage.

44700 004-3 (2’)
44700 005-2 (6’)
• Volts/Amps: 120V/30A • Cord Gauge: 10/3 AWG • NEMA L5-30P & R
• Trip Level: 4 - 6 mA

Southwire's Technology Research Corporation (TRC) GFCI Inline Cord Sets 44700 (120V/30 A)  44720 (240V/30 A) are designed for rugged duty.  Plug and Receptacles are molded from high impact polymer with booted reset and test buttons.  The TRC 44700/44720 series are at home in hostile environments such as industrial, construction, maintenance and commercial work sites. Cord Gauge is 10/3 AWG for maximum strength and durability. Ideal for use by contractors and industrial maintenance personnel working with extension cords or portable tools.  Provides compliance with National Electric Code (NEC 2008) Article 590.6 for Temporary Installations. Applications include: High Pressure Sprayer Washers, Power Tools, Drain Snakes, Pumps, Construction Sites, Industrial Appliances. The TRC GFCI is Rainproof rated, UL listed for outdoor use.  Cord lengths are 2, 6 and 25 feet. The 120 version does not have a 25' length, only 2' and 6'.Voltage rating are 120 and 240 vac, amperage rating is 30, trip level is 4-6mA and has standard 120 or  240 volt NEMA L5 or L6-30 Black Plug & Receptacle. To prevent unmonitored equipment startup, manual reset is required after GFCI trips and power outages or when you unplug and plug back in.

44720 012-3 (3’)
44720 013-2 (6’)
44720 020-1 (25’)
• Volts/Amps: 240V/30A • Cord Gauge: 10/3 AWG • NEMA L6-30P & R

• Trip Level: 4 - 6 mA 

APPLICATIONS INCLUDE 

• High Pressure Sprayer Washers 

• Construction Site Power Tools 

• Drain Snakes

• Pumps

• Industrial Appliances 

• Construction Sites

GROUNDED NEUTRAL   

4 Ohms

TRIP RESPONSE TIME FOR GROUND FAULT 

AND GROUNDED NEUTRAL TRIP  

Less Than 25mS

VOLTAGE SURGE WITHSTAND     

3kv ringwave test and 4kv/2kA surge immunity test

RADIO FREQUENCY NOISE SUSCEPTIBILITY   

Operates Within Normal Limits With 0.5 Volts 

Injected On Power Line 150Khz-230Mhz

FREQUENCY   

60 Hz

ENDURANCE   

3,000 Operations Minimum

OVERLOAD CURRENT   

Six Times Rated Current

OPERATING TEMPERATURE RANGE  

 -35 ̊C to 66 ̊C

EFFECT OF 10 AMP TURN DC SHOCK FAULT TRIP     

5% Maximum Trip Level Variation on Ground 

INSULATION VOLTAGE   

1500 Vrms - 1 Min.

POWER ON INDICATION    

Lighted Indicator 


Anderson-Bolds sells TRC Ground Fault Circuit Interrupters 


Southwire TRC 120 volt 30 amp GFCIs

44700 004-3 (2’)
44700 005-2 (6’)

Southwire TRC 240 volt 30 amp GFCIs

44720 012-3 (3’)
44720 013-2 (6’)
44720 020-1 (25’)