Southwire TRC 30 Amp GFCIs with Twist Lock Plugs

Southwire  TRC series 44700 and 44720 30 amp GFCIs 

See all of our ground fault circuit interrupters HERE!

30 amp GFCI IN-LINE Cord Sets with Manual Reset.

TRC 30 Amp GFCI's
44700 004-3, 44700 005-2
44720 012-3,  44720 013-2, 44720 020-1
 















Designed for rugged duty. Molded from high impact polymer with booted reset and test buttons. At home in hostile environments such as industrial, construction, maintenance and commercial work sites. Provides compliance with National Electric Code (NEC 2008) Article 590.6 for “Temporary Installations.” Rainproof rated, UL listed for outdoor use. Standard lengths:
2’, 6’, and 25’ with corresponding locking connectors. Custom cable gauges, lengths and terminations available by special order. To prevent unmonitored equipment startup, manual reset is required after GFCI trip and power outage.

44700 004-3 (2’)
44700 005-2 (6’)
• Volts/Amps: 120V/30A • Cord Gauge: 10/3 AWG • NEMA L5-30P & R
• Trip Level: 4 - 6 mA

Southwire's Technology Research Corporation (TRC) GFCI Inline Cord Sets 44700 (120V/30 A)  44720 (240V/30 A) are designed for rugged duty.  Plug and Receptacles are molded from high impact polymer with booted reset and test buttons.  The TRC 44700/44720 series are at home in hostile environments such as industrial, construction, maintenance and commercial work sites. Cord Gauge is 10/3 AWG for maximum strength and durability. Ideal for use by contractors and industrial maintenance personnel working with extension cords or portable tools.  Provides compliance with National Electric Code (NEC 2008) Article 590.6 for Temporary Installations. Applications include: High Pressure Sprayer Washers, Power Tools, Drain Snakes, Pumps, Construction Sites, Industrial Appliances. The TRC GFCI is Rainproof rated, UL listed for outdoor use.  Cord lengths are 2, 6 and 25 feet. The 120 version does not have a 25' length, only 2' and 6'.Voltage rating are 120 and 240 vac, amperage rating is 30, trip level is 4-6mA and has standard 120 or  240 volt NEMA L5 or L6-30 Black Plug & Receptacle. To prevent unmonitored equipment startup, manual reset is required after GFCI trips and power outages or when you unplug and plug back in.

44720 012-3 (3’)
44720 013-2 (6’)
44720 020-1 (25’)
• Volts/Amps: 240V/30A • Cord Gauge: 10/3 AWG • NEMA L6-30P & R

• Trip Level: 4 - 6 mA 

APPLICATIONS INCLUDE 

• High Pressure Sprayer Washers 

• Construction Site Power Tools 

• Drain Snakes

• Pumps

• Industrial Appliances 

• Construction Sites

GROUNDED NEUTRAL   

4 Ohms

TRIP RESPONSE TIME FOR GROUND FAULT 

AND GROUNDED NEUTRAL TRIP  

Less Than 25mS

VOLTAGE SURGE WITHSTAND     

3kv ringwave test and 4kv/2kA surge immunity test

RADIO FREQUENCY NOISE SUSCEPTIBILITY   

Operates Within Normal Limits With 0.5 Volts 

Injected On Power Line 150Khz-230Mhz

FREQUENCY   

60 Hz

ENDURANCE   

3,000 Operations Minimum

OVERLOAD CURRENT   

Six Times Rated Current

OPERATING TEMPERATURE RANGE  

 -35 ̊C to 66 ̊C

EFFECT OF 10 AMP TURN DC SHOCK FAULT TRIP     

5% Maximum Trip Level Variation on Ground 

INSULATION VOLTAGE   

1500 Vrms - 1 Min.

POWER ON INDICATION    

Lighted Indicator 


Anderson-Bolds sells TRC Ground Fault Circuit Interrupters 


Southwire TRC 120 volt 30 amp GFCIs

44700 004-3 (2’)
44700 005-2 (6’)

Southwire TRC 240 volt 30 amp GFCIs

44720 012-3 (3’)
44720 013-2 (6’)
44720 020-1 (25’)


Anderson-Bolds


GFCI...GFCI...GFCI...GFCI...GFCI

Tuesday, December 1, 2020

GFCI's and OSHA Violations

 GFCI Products to Remedy OSHA Violations

TRC GFCI 14650-006







An OSHA violation is a serious matter. Many of them can result in injury or death. Some violations are obvious and easy to spot while others require training and a comprehensive understanding of the requirements in order to detect them.

For example, improper Lockout/Tagout of energized equipment or machine guarding, although not simple, might be easier to notice and correct than electrical code violations that require a detailed understanding of the written rules and are likely to be unnoticed by many at the site.

Although most of the people understand basic electricity (e.g., not sticking metal objects into outlets,  it is still perceived as a very complicated topic.

However, not all electrical violations are complicated. Some basic OSHA-mandated safety requirements are very easy to spot and correct if one knows what to look for. Among the top ten most frequently cited standards violations for 2014-2015, electrical-related standards violations are number 8 and 10 on the list.


Top 10 Most Frequently Cited Standards violations for Fiscal 2015 (Oct. 1, 2014, to Sept. 30, 2015)

1.       Fall Protection (1926.501)

2.       Hazard Communication (1910.1200)

3.       Scaffolding (1926.451)

4.       Respiratory Protection (1910.134)

5.       Lockout/Tag Out (1910.147)

6.       Powered Industrial Trucks (1910.178)

7.       Ladders (1926.1053)

8.       Electrical – Wiring Methods (1910.305)

9.       Machine Guarding (1910.212)

10.     Electrical – General Requirements (1910.303)


Anderson-Bolds can help with Fall Protection, Lockout/Tag Out,

 Machine Guarding and Electrical (GFCIs).


30 Amp Inline GFCI with locking plugs





Now we are unlikely to be able to educate everyone on everything, but what we can achieve is to give some basic ideas on how these violations can be decreased and potentially save lives. If, as a result of this article, we save one life we could not be happier and it is sad to see people getting injured for something that is so easy to avoid.

So what exactly is so easy to fix? Use a work site Ground Fault Circuit Interrupter or GFCI for short! If you have employees working in a location that has temporary power, it is highly recommended to use a GFCI on every electrical circuit or service, even if there are no OSHA regulations requiring it.

For example , with the use of tools like wet vacs, power washers, wet saws or drills used to mix cement, it is a good practice to have GFCI’s installed to protect employees who work with this equipment. Per OSHA, all construction sites and construction site-like activities that use extension cords or certain equipment have to be GFCI protected2. As a rule of thumb, if you have power equipment outdoors, or near moisture/water you need to use GFCI-protected devices. OSHA estimates that since the GFCI requirement was implemented in 1970, the rule has saved more than 650 lives. That is one person a month since 1970!  

What is a GFCI? (Ground Fault Circuit Interrupter)

GFCI is an electrical device that measures the difference between output and input load current, opening whenever a difference is detected that could pose a safety hazard. If there is a current difference of more than 6 milliamps (mA), the GFCI unit will disconnect power to the load. Don’t be fooled into using a standard circuit breaker. Circuit breakers are designed to protect equipment not people!

GFCI’s come in a variety of forms and shapes, but for MRO or construction industries, the two most common options are right angle plug adapters or corded GFCIs that have a power cord and multiple output sockets. Each type might come with various additional features, especially the corded models. Corded models can offer different cord lengths from 2 ft up to 100 ft long, and also illuminated outlets and various socket configurations.

Something to remember is that socket multipliers and surge protectors are not the same as a Ground Fault Circuit Interrupter or GFCI for short. A GFCI is the only device designed specifically to protect people, whereas everything else is designed to protect equipment from damage due to high voltage transients. This is important to remember in order to choose the appropriate device for its intended application. If you have a device and you want to protect equipment from damaging power transients, then use a surge protector. However, if your primary concern is to protect employees, a GFCI is the only product capable of doing it.

A properly designed and manufactured GFCI unit will continue to provide protection when hazardous wiring conditions present. For example mis-wiring the neutral wire and a hot wire at the circuit breaker or outlet will not impede the GFCI’s ability to offer protection.

There are certain circumstances when a GFCI might not prevent a shock, such as when a person touches  both electric wires at the same time, offering a path from one wire in through one hand, through the body, and out on the other hand to the other electric wire. In this situation the GFCI will not sense a current imbalance and will not trip. This is a very important point to consider when training personnel working on equipment with GFCIs.

GFCI’s are intended to trip if current is passing through a path to ground; this could be from a tool or piece of equipment through the user. The GFCI is intended to trip quickly, so the user is not harmed.

It should be noted that a shock can be felt even with a GFCI, but the GFCI will trip quickly enough to avoid an injury.

When looking for a GFCI something to keep in mind is the design of the product. Although there are a lot of products available on the market, the most reliable products carry a UL approval. UL is the leading safety organization with best test and follow up practices. This ensures products are produced with safety critical aspects continually tested and validated in the factory. You might find some products that are few dollars cheaper, but do not carry UL approval and they may perform just as well. The key here is “may”. Products that have UL approval have undergone the most rigorous testing and follow up inspection, and so it should be the “product of choice” when personnel safety is important.

Having several of the GFCI products in your department is just as easy as having many extension cords. GFCI’s become second nature once employees are trained to use them. No one wants to get electrocuted or injured. It is very easy to use them and highly effective in any environment!

TRC HD-Pro 24646-001 30 Amp Unit










Repeating: What is a GFCI

A ground-fault occurs when there is a break in the low-resistance grounding path from a tool or electrical system. The electrical current may then take an alternative path to the ground through the user, resulting in serious injuries or death. The ground-fault circuit interrupter, or GFCI, is a fast-acting circuit breaker designed to shut off electric power in the event of a ground-fault within as little as 1/40 of a second. It works by comparing the amount of current going to and returning from equipment along the circuit conductors. When the amount going differs from the amount returning by approximately 5 milliamperes, the GFCI interrupts the current.

The GFCI is rated to trip quickly enough to prevent an electrical incident. If it is properly installed and maintained, this will happen as soon as the faulty tool is plugged in. If the grounding conductor is not intact or of low-impedance, the GFCI may not trip until a person provides a path. In this case, the person will receive a shock, but the GFCI should trip so quickly that the shock will not be harmful.

The GFCI will not protect you from line contact hazards (i.e. a person holding two "hot" wires, a hot and a neutral wire in each hand, or contacting an overhead power line). However, it protects against the most common form of electrical shock hazard, the ground-fault. It also protects against fires, overheating, and destruction of wire insulation.

View Anderson-Bolds Safety Equipment HERE!

Anderson-Bolds
216-360-9800
www.anderson-bolds.com

GFCI...GFCI...GFCI...GFCI...GFCI...GFCI...GFCI...GFCI

Thursday, August 9, 2018

Carlo Gavazzi Earth Leakage Monitors

Carlo Gavazzi Earth Leakage (grounding) Monitor Relays

For quotes and information, please go to our Contact Anderson-Bolds page  HERE.


CARLO GAVAZZI is proud to announce the launch of two new Earth Leakage Monitoring Relays, the DEA71 and DEB71. When used in conjunction with a CTG Series Core Balance Current Transformer and appropriate circuit breaker, they provide machine protection against fault currents, and help to reduce fire hazards. These earth leakage relays react to small changes in current which can occur due to insulation or grounding failure.
Two models, each offering choices of threshold ranges, allow users to find the right solution for their unique requirements. The DEA71 features fixed trip levels which offer time-saving installation, with a reliable tripping level and safety against tampering. The DEB71 provides ability to adjust trip levels and includes an adjustable time delay; a lockable front cover provides further tamper protection.
A key advantage offered by DEA71 and DEB71 is avoidance of nuisance tripping in the circuit, in accordance with the EN 60947-2 Annex M norm. Two separate alarm outputs allow for a warning signal to be generated before a shutdown is necessary. Their compact (35mm wide) housing preserves valuable panel space.
The DEA71 and DEB71 from Carlo Gavazzi perform crucial monitoring of earth leakage, prolonging machine life by limiting damage from ground faults as well as reducing fire risk. They conform to global standards such as UL 508, CSA C22.2 and EN 60947-2 Annex M.
The features of the DEA71 and DEB71 Earth Leakage Relays include:
 page1image14184
  •   DEA71 includes two models with fixed trip setting: 30 mA and 300 mA
  •   DEB71 includes two models with adjustable trip levels: 30 mA to 5 A and 300 mA to 30 A
2 SPDT relay outputs, for warning and for alarm 24 VAC to 240 VAC power supply
NORM DIN-rail housing 35 mm
Lockable lid on adjustable models (DEB71)
The DEA71 and DEB71 Monitors and CTG Series Core Balance Current Transformers are available from 

Anderson-Bolds
216-360-9800
www.anderson-bolds.com

Saturday, April 30, 2016

TRC Southwire High Power 100 Amp GFCI - ELCI

Anderson-Bolds sells TRC / Southwire GFCI's and ELCI's up to 100 AMPS.

These are the  new Southwire TRC 24736-001 and 24994-001 100 amp 6-10-30 Trip Level GFCI and ELCI Units.

Anderson-Bolds is your source for Commercial safety products including GFCIs and ELCIs.

GFCIs and ELCIs are used for personnel and equipment protection.


TRC has engineered a new option for the HD-PROTM series called 6.10.30TM.
Configured for both in-line and bulk head mount. This unique new design allows the user to select and lock in the most sensitive trip level at which a specific type of equipment can be operated without nuisance tripping. Adjustable settings
include trip levels for 6mA, 10mA and 30mA. Trip level flexibility to meet your needs in one single device - HD-PROTM with 6.10.30TM.  6.10.30TM key enables trip level selection and locking at a trip level with key removal.  

The GFCIs protect Motors, Pumps, Pressure Washers, Conveyors, Welders and lifts.

Go To GFCI/ELCI Store Page HERE. or call 216-360-9800


TRC 24736-001 and TRC 24994-001
100 amp GFCI/ELCI





















Specifications:

Voltage:  480 or 600 volts AC and three phase
AMPS: 100
Cord Gauge: 2/4 AWG
Trip Levels: 6mA, 10mA, 30mA - chosen by Key Switch
GFCI Response Time: 25mS
Frequency: 50/60 Hz
Endurance: 3,000 operations minimum
Overload Current: SIX times rated current
Temperature Range: -20C to +40C
Power n Indicator: Light
Drop Out Voltage: About 60% rated voltage
Reset Type: Auto
Connection: Flying Leads
Enclosure: NEMA 4 Polymer



216-360-9800
www.anderson-bolds.com





Thursday, April 26, 2012

TRC Coleman Cable GFCI's

Anderson-Bolds Stocks TRC and now Coleman Cable GFCI's and ELCI's.

At present the following are in stock in our warehouse.



TRC GFCI 44720 with 6 ft. cord with twist lock plugs , 120 or 240 volts, 30 amps




TRC GFCI 33120 panel mount GFCI, 120 volts, 20 amps

TRC GFCI 32120 panel mount GFCI, 120 volts and 20 amps



TRC GFCI 14880-037, 120 volt 15 amp GFCI and Strip


TRC and  Coleman Cable also stock a large percentage of their GFCI's and ELCI's.

Some have required package quantities.

Please call Anderson-Bolds to order or click on the links above.

866-360-9810 or email to info@anderson-bolds.com or fill in our request form here.


Sunday, August 7, 2011

HD Pro TRC High Power GFCIs and ELCIs


TRC manufacturers High Power Ground Fault and Equipment Fault products for personnel and equipment safety.


Please view the TRC Safety Ground Fault Video Here.


The below series of HDPRO units cover 30 and 60 amps and voltages of 277, 480, and 208-240.

Configured for both in-line and bulk head mount. Engineered to trip within 25 milliseconds. Protects:

�� Motors �� Pumping Systems �� Pressure Washers Has 2’of cable on both line and load side. To prevent equipment startup after

GFCI/ELCI trips,manual reset required. Will reset on power restoration following disruption of primary power. 6.10.30TM key enable strip level selection and locking at a trip level with key removal.


PDF link is Here.


TRC HD-Pro GFCI / ELCI 24396-001

Volts/Amps: 277V/30A

Cord Gauge: 10/3 AWG.

Trip Level: 6, 10 & 30mA

Single Phase


TRC HD-Pro GFCI / ELCI

24672-001

Volts/Amps: 480V/60A

Cord Gauge: 4/4 AWG.

Trip Level: 6, 10 & 30mA

Three Phase


TRC HD-Pro GFCI / ELCI

24542-001

Volts/Amps: 208-240V/60A

Cord Gauge: 4/4 AWG.

Trip Level: 6, 10 & 30mA

Three Phase


TRC HD-Pro GFCI / ELCI

24846-001

Volts/Amps: 208-240V/30A

Cord Gauge: 8/5 AWG.

Trip Level: 6, 10 & 30mA

Three Phase


TRC HD-Pro GFCI / ELCI

24646-001

Volts/Amps: 480V/30A

Cord Gauge: 10/4 AWG.

Trip Level: 6, 10 & 30mA

Three Phase


The below HD Pro models are al 60 amps and come in voltages of 120, 380 and 240.

Configured for both in-line and bulk head mount. Engineered to trip within 25 milliseconds. Protects:

�� Motors �� Pumping Systems �� Pressure Washers Has 2’of cable on both line and load side. To prevent equipment startup after

�� Manufacturing Equipment �� Welders �� Hoists

ELCI trips, manual reset required. Will reset on power restoration following disruption of primary power.


PDF link is here.


TRC HD PRO GFCI / ELCI 24520-001

�� Volts/Amps: 120V/60A �� Cord Gauge: 4/3 AWG. �� Trip Level: 10 mA �� Single Phase


TRC HD-RPO ELCI / GFCI 25560-001

�� Volts/Amps: 380V/60A �� Cord Gauge: 4/4 AWG. �� Trip Level: 30 mA �� Three Phase


TECHNOLOGY RESEARCH CORP HD PRO ELCI / GFCI 24530-001

�� Volts/Amps: 240V/60A �� Cord Gauge: 4/4 AWG. �� Trip Level: 10 mA �� Three Phase



The below TRC HDPRO units are rated 60 amps and 80 amps and have voltages of 208-240, 480 and 600.


PDF link is here.


TRC HD PRO HIGH POWER ELCI / GFIC 24786-001

�� Volts/Amps: 208-240V/80A �� Cord Gauge: 4/4 AWG. �� Trip Level: 6, 10 & 30 mA �� Three Phase


Technology Research HD-PRO ELCI / GFCI 24946-003

�� Volts/Amps: 600V/60A �� Cord Gauge: 4/4 AWG. �� Trip Level: 6, 10 & 30 mA �� Three Phase


HD PRO by TRC High Power GFCI / ELCI 24796-001

�� Volts/Amps: 480V/80A �� Cord Gauge: 4/4 AWG. �� Trip Level: 6, 10 & 30 mA �� Three Phase


HD-PRO TRC High Power GFCI / ELCI 24992-001

�� Volts/Amps: 600V/80A �� Cord Gauge: 4/4 AWG. �� Trip Level: 6, 10 & 30 mA �� Three Phase


The below TRC Units are EGFPDs and are CSA approved. the units are 30 and 60 amps and 208/240 and 480 volts.

EGFPD = Equipment Ground Fault Protection Device


Configured for both in-line and bulk head mount. Engineered to trip within 25 milliseconds. Protects:

�� Motors �� Pumping Systems �� Pressure Washers To prevent equipment startup after EGFPD or GFCI/ELCI trips, manual reset re-

�� Manufacturing Equipment �� Welders �� Hoists

quired. Will reset on power restoration following disruption of primary power. Key en- ables trip level selection and locks at a trip level with key removal.

The PDF file is here.


TRC 44110 EGFPD ( CSA Approved)

�� Volts/Amps: 208-240V/30A �� Trip Level: 10, 30 & 50 mA �� Three Phase


Technology Research Corporation 44140 EGFPD CSA Approved

�� Volts/Amps: 208-240V/60A �� Trip Level: 10, 30 & 50 mA �� Three Phase


TRC 44120 EGFPD ( CSA Approved Device )

�� Volts/Amps: 480V/30A �� Trip Level: 10, 30 & 50 mA �� Three Phase


Technology Research Corp. CSA Approved 44130 EGFPD

�� Volts/Amps: 480V/60A �� Trip Level: 10, 30 & 50 mA �� Three Phase


The below TRC Units are ELCIs and and GFCIs are 30 and 60 amps and 208/240 and 480 volts and have adjustable trip points of 6-10-30 amperes (amps).

Configured for both in-line and bulk head mount. Engineered to trip within 25 milliseconds. Protects:

�� Motors �� Pumping Systems �� Pressure Washers To prevent equipment startup after EGFPD or GFCI/ELCI trips, manual reset re-

�� Manufacturing Equipment �� Welders �� Hoists

quired. Will reset on power restoration following disruption of primary power. Key en- ables trip level selection and locks at a trip level with key removal.

The PDF file is here.


Technology Research Corporation 44610 GFCI/ELCI

�� Volts/Amps: 208-240V/30A �� Trip Level: 6,10 & 30 mA �� Three Phase


TRC 44640 GFCI/ELCI

�� Volts/Amps: 208-240V/60A �� Trip Level: 6,10 & 30 mA �� Three Phase


TRC 44620 GFCI/ELCI

�� Volts/Amps: 480V/30A �� Trip Level: 6,10 & 30 mA �� Three Phase


Technology Research Corp. 44630 GFCI/ELCI

�� Volts/Amps: 480V/60A �� Trip Level: 6,10 & 30 mA �� Three Phase


Our complete list of the HD Pro models by TRC is located here.


To see Anderson-Bolds' other products please go to www.anderson-bolds.com.




TECHNICAL DATA