Southwire TRC 30 Amp GFCIs with Twist Lock Plugs

Southwire  TRC series 44700 and 44720 30 amp GFCIs 

See all of our ground fault circuit interrupters HERE!

30 amp GFCI IN-LINE Cord Sets with Manual Reset.

TRC 30 Amp GFCI's
44700 004-3, 44700 005-2
44720 012-3,  44720 013-2, 44720 020-1
 















Designed for rugged duty. Molded from high impact polymer with booted reset and test buttons. At home in hostile environments such as industrial, construction, maintenance and commercial work sites. Provides compliance with National Electric Code (NEC 2008) Article 590.6 for “Temporary Installations.” Rainproof rated, UL listed for outdoor use. Standard lengths:
2’, 6’, and 25’ with corresponding locking connectors. Custom cable gauges, lengths and terminations available by special order. To prevent unmonitored equipment startup, manual reset is required after GFCI trip and power outage.

44700 004-3 (2’)
44700 005-2 (6’)
• Volts/Amps: 120V/30A • Cord Gauge: 10/3 AWG • NEMA L5-30P & R
• Trip Level: 4 - 6 mA

Southwire's Technology Research Corporation (TRC) GFCI Inline Cord Sets 44700 (120V/30 A)  44720 (240V/30 A) are designed for rugged duty.  Plug and Receptacles are molded from high impact polymer with booted reset and test buttons.  The TRC 44700/44720 series are at home in hostile environments such as industrial, construction, maintenance and commercial work sites. Cord Gauge is 10/3 AWG for maximum strength and durability. Ideal for use by contractors and industrial maintenance personnel working with extension cords or portable tools.  Provides compliance with National Electric Code (NEC 2008) Article 590.6 for Temporary Installations. Applications include: High Pressure Sprayer Washers, Power Tools, Drain Snakes, Pumps, Construction Sites, Industrial Appliances. The TRC GFCI is Rainproof rated, UL listed for outdoor use.  Cord lengths are 2, 6 and 25 feet. The 120 version does not have a 25' length, only 2' and 6'.Voltage rating are 120 and 240 vac, amperage rating is 30, trip level is 4-6mA and has standard 120 or  240 volt NEMA L5 or L6-30 Black Plug & Receptacle. To prevent unmonitored equipment startup, manual reset is required after GFCI trips and power outages or when you unplug and plug back in.

44720 012-3 (3’)
44720 013-2 (6’)
44720 020-1 (25’)
• Volts/Amps: 240V/30A • Cord Gauge: 10/3 AWG • NEMA L6-30P & R

• Trip Level: 4 - 6 mA 

APPLICATIONS INCLUDE 

• High Pressure Sprayer Washers 

• Construction Site Power Tools 

• Drain Snakes

• Pumps

• Industrial Appliances 

• Construction Sites

GROUNDED NEUTRAL   

4 Ohms

TRIP RESPONSE TIME FOR GROUND FAULT 

AND GROUNDED NEUTRAL TRIP  

Less Than 25mS

VOLTAGE SURGE WITHSTAND     

3kv ringwave test and 4kv/2kA surge immunity test

RADIO FREQUENCY NOISE SUSCEPTIBILITY   

Operates Within Normal Limits With 0.5 Volts 

Injected On Power Line 150Khz-230Mhz

FREQUENCY   

60 Hz

ENDURANCE   

3,000 Operations Minimum

OVERLOAD CURRENT   

Six Times Rated Current

OPERATING TEMPERATURE RANGE  

 -35 ̊C to 66 ̊C

EFFECT OF 10 AMP TURN DC SHOCK FAULT TRIP     

5% Maximum Trip Level Variation on Ground 

INSULATION VOLTAGE   

1500 Vrms - 1 Min.

POWER ON INDICATION    

Lighted Indicator 


Anderson-Bolds sells TRC Ground Fault Circuit Interrupters 


Southwire TRC 120 volt 30 amp GFCIs

44700 004-3 (2’)
44700 005-2 (6’)

Southwire TRC 240 volt 30 amp GFCIs

44720 012-3 (3’)
44720 013-2 (6’)
44720 020-1 (25’)


Anderson-Bolds


GFCI...GFCI...GFCI...GFCI...GFCI

Wednesday, December 2, 2020

TRC Electra Check Power Monitor

 TRC/Southwire Digital Power Monitor AECM20020


The TRC Electra Check (AECM20020) is a compact, easy to use instrument is made with advanced microelectronics and provides accurate testing and monitoring of electrical outlets and systems.  Constantly monitors voltage and frequency indicating potential improper polarity and ground wiring.  Its small size and rugged construction allows for convenient installation in an electrical outlet or use as a portable service tool.

Voltage is measured as RMS which is much more precise than AC average.  RMS metering is the only method that can accurately measure all AC power sources.  The RMS voltage and frequency readings are ideal for monitoring modified sine waves such as solid-state generators, inverters and Uninterruptible Power Supply (UPS) products.

The Digital Monitor display will alternate between line voltage in RMS volts and line frequency in Hertz. The LCD display shows an F in front of the reading to denote frequency. Pressing the MODE button on the front of the Digital Monitor will cycle through the display modes. Both voltage and frequency are constantly monitored regardless of the display mode.

Fully tests incoming power for: Open ground, Reverse polarity,High/Low voltage. Three display modes available: Alternating voltage and frequency (VOLT/FREQ.), Voltage only (VOLTAGE), Frequency only (FREQUENCY)

Electra Check is about 2x3 inches. The TRC part number is AECM20020.

TRC AECM20020-3-012 Electra Check Digital Monitor for All AC Power Sources, Black with White Face











Anderson-Bolds
216-360-9800
www.anderson-bolds.com

Saturday, April 30, 2016

TRC Southwire High Power 100 Amp GFCI - ELCI

Anderson-Bolds sells TRC / Southwire GFCI's and ELCI's up to 100 AMPS.

These are the  new Southwire TRC 24736-001 and 24994-001 100 amp 6-10-30 Trip Level GFCI and ELCI Units.

Anderson-Bolds is your source for Commercial safety products including GFCIs and ELCIs.

GFCIs and ELCIs are used for personnel and equipment protection.


TRC has engineered a new option for the HD-PROTM series called 6.10.30TM.
Configured for both in-line and bulk head mount. This unique new design allows the user to select and lock in the most sensitive trip level at which a specific type of equipment can be operated without nuisance tripping. Adjustable settings
include trip levels for 6mA, 10mA and 30mA. Trip level flexibility to meet your needs in one single device - HD-PROTM with 6.10.30TM.  6.10.30TM key enables trip level selection and locking at a trip level with key removal.  

The GFCIs protect Motors, Pumps, Pressure Washers, Conveyors, Welders and lifts.

Go To GFCI/ELCI Store Page HERE. or call 216-360-9800


TRC 24736-001 and TRC 24994-001
100 amp GFCI/ELCI





















Specifications:

Voltage:  480 or 600 volts AC and three phase
AMPS: 100
Cord Gauge: 2/4 AWG
Trip Levels: 6mA, 10mA, 30mA - chosen by Key Switch
GFCI Response Time: 25mS
Frequency: 50/60 Hz
Endurance: 3,000 operations minimum
Overload Current: SIX times rated current
Temperature Range: -20C to +40C
Power n Indicator: Light
Drop Out Voltage: About 60% rated voltage
Reset Type: Auto
Connection: Flying Leads
Enclosure: NEMA 4 Polymer



216-360-9800
www.anderson-bolds.com





Thursday, April 26, 2012

TRC Coleman Cable GFCI's

Anderson-Bolds Stocks TRC and now Coleman Cable GFCI's and ELCI's.

At present the following are in stock in our warehouse.



TRC GFCI 44720 with 6 ft. cord with twist lock plugs , 120 or 240 volts, 30 amps




TRC GFCI 33120 panel mount GFCI, 120 volts, 20 amps

TRC GFCI 32120 panel mount GFCI, 120 volts and 20 amps



TRC GFCI 14880-037, 120 volt 15 amp GFCI and Strip


TRC and  Coleman Cable also stock a large percentage of their GFCI's and ELCI's.

Some have required package quantities.

Please call Anderson-Bolds to order or click on the links above.

866-360-9810 or email to info@anderson-bolds.com or fill in our request form here.


Sunday, August 7, 2011

HD Pro TRC High Power GFCIs and ELCIs


TRC manufacturers High Power Ground Fault and Equipment Fault products for personnel and equipment safety.


Please view the TRC Safety Ground Fault Video Here.


The below series of HDPRO units cover 30 and 60 amps and voltages of 277, 480, and 208-240.

Configured for both in-line and bulk head mount. Engineered to trip within 25 milliseconds. Protects:

�� Motors �� Pumping Systems �� Pressure Washers Has 2’of cable on both line and load side. To prevent equipment startup after

GFCI/ELCI trips,manual reset required. Will reset on power restoration following disruption of primary power. 6.10.30TM key enable strip level selection and locking at a trip level with key removal.


PDF link is Here.


TRC HD-Pro GFCI / ELCI 24396-001

Volts/Amps: 277V/30A

Cord Gauge: 10/3 AWG.

Trip Level: 6, 10 & 30mA

Single Phase


TRC HD-Pro GFCI / ELCI

24672-001

Volts/Amps: 480V/60A

Cord Gauge: 4/4 AWG.

Trip Level: 6, 10 & 30mA

Three Phase


TRC HD-Pro GFCI / ELCI

24542-001

Volts/Amps: 208-240V/60A

Cord Gauge: 4/4 AWG.

Trip Level: 6, 10 & 30mA

Three Phase


TRC HD-Pro GFCI / ELCI

24846-001

Volts/Amps: 208-240V/30A

Cord Gauge: 8/5 AWG.

Trip Level: 6, 10 & 30mA

Three Phase


TRC HD-Pro GFCI / ELCI

24646-001

Volts/Amps: 480V/30A

Cord Gauge: 10/4 AWG.

Trip Level: 6, 10 & 30mA

Three Phase


The below HD Pro models are al 60 amps and come in voltages of 120, 380 and 240.

Configured for both in-line and bulk head mount. Engineered to trip within 25 milliseconds. Protects:

�� Motors �� Pumping Systems �� Pressure Washers Has 2’of cable on both line and load side. To prevent equipment startup after

�� Manufacturing Equipment �� Welders �� Hoists

ELCI trips, manual reset required. Will reset on power restoration following disruption of primary power.


PDF link is here.


TRC HD PRO GFCI / ELCI 24520-001

�� Volts/Amps: 120V/60A �� Cord Gauge: 4/3 AWG. �� Trip Level: 10 mA �� Single Phase


TRC HD-RPO ELCI / GFCI 25560-001

�� Volts/Amps: 380V/60A �� Cord Gauge: 4/4 AWG. �� Trip Level: 30 mA �� Three Phase


TECHNOLOGY RESEARCH CORP HD PRO ELCI / GFCI 24530-001

�� Volts/Amps: 240V/60A �� Cord Gauge: 4/4 AWG. �� Trip Level: 10 mA �� Three Phase



The below TRC HDPRO units are rated 60 amps and 80 amps and have voltages of 208-240, 480 and 600.


PDF link is here.


TRC HD PRO HIGH POWER ELCI / GFIC 24786-001

�� Volts/Amps: 208-240V/80A �� Cord Gauge: 4/4 AWG. �� Trip Level: 6, 10 & 30 mA �� Three Phase


Technology Research HD-PRO ELCI / GFCI 24946-003

�� Volts/Amps: 600V/60A �� Cord Gauge: 4/4 AWG. �� Trip Level: 6, 10 & 30 mA �� Three Phase


HD PRO by TRC High Power GFCI / ELCI 24796-001

�� Volts/Amps: 480V/80A �� Cord Gauge: 4/4 AWG. �� Trip Level: 6, 10 & 30 mA �� Three Phase


HD-PRO TRC High Power GFCI / ELCI 24992-001

�� Volts/Amps: 600V/80A �� Cord Gauge: 4/4 AWG. �� Trip Level: 6, 10 & 30 mA �� Three Phase


The below TRC Units are EGFPDs and are CSA approved. the units are 30 and 60 amps and 208/240 and 480 volts.

EGFPD = Equipment Ground Fault Protection Device


Configured for both in-line and bulk head mount. Engineered to trip within 25 milliseconds. Protects:

�� Motors �� Pumping Systems �� Pressure Washers To prevent equipment startup after EGFPD or GFCI/ELCI trips, manual reset re-

�� Manufacturing Equipment �� Welders �� Hoists

quired. Will reset on power restoration following disruption of primary power. Key en- ables trip level selection and locks at a trip level with key removal.

The PDF file is here.


TRC 44110 EGFPD ( CSA Approved)

�� Volts/Amps: 208-240V/30A �� Trip Level: 10, 30 & 50 mA �� Three Phase


Technology Research Corporation 44140 EGFPD CSA Approved

�� Volts/Amps: 208-240V/60A �� Trip Level: 10, 30 & 50 mA �� Three Phase


TRC 44120 EGFPD ( CSA Approved Device )

�� Volts/Amps: 480V/30A �� Trip Level: 10, 30 & 50 mA �� Three Phase


Technology Research Corp. CSA Approved 44130 EGFPD

�� Volts/Amps: 480V/60A �� Trip Level: 10, 30 & 50 mA �� Three Phase


The below TRC Units are ELCIs and and GFCIs are 30 and 60 amps and 208/240 and 480 volts and have adjustable trip points of 6-10-30 amperes (amps).

Configured for both in-line and bulk head mount. Engineered to trip within 25 milliseconds. Protects:

�� Motors �� Pumping Systems �� Pressure Washers To prevent equipment startup after EGFPD or GFCI/ELCI trips, manual reset re-

�� Manufacturing Equipment �� Welders �� Hoists

quired. Will reset on power restoration following disruption of primary power. Key en- ables trip level selection and locks at a trip level with key removal.

The PDF file is here.


Technology Research Corporation 44610 GFCI/ELCI

�� Volts/Amps: 208-240V/30A �� Trip Level: 6,10 & 30 mA �� Three Phase


TRC 44640 GFCI/ELCI

�� Volts/Amps: 208-240V/60A �� Trip Level: 6,10 & 30 mA �� Three Phase


TRC 44620 GFCI/ELCI

�� Volts/Amps: 480V/30A �� Trip Level: 6,10 & 30 mA �� Three Phase


Technology Research Corp. 44630 GFCI/ELCI

�� Volts/Amps: 480V/60A �� Trip Level: 6,10 & 30 mA �� Three Phase


Our complete list of the HD Pro models by TRC is located here.


To see Anderson-Bolds' other products please go to www.anderson-bolds.com.




TECHNICAL DATA

Saturday, July 16, 2011

Fire Shield for College Students ~ PROTECTION from Dorm fires



Fire Shield is a next generation extension cord with built-in intelligence to sense cord damage and shut off the power before a fire can start. No other extension cord has this capability.
Industry statistics indicate there is a cord fire approximately every 6 minutes. The most frequent causes of such fires are short circuits, overloading, damage, and/or misuse of extension cords.
A special shield surrounds each of the insulated conductors of the Fire Shield Extension Cord. The shield is continuously monitored by electronics in the plug head. When a dangerous electrical condition is detected by current leaking to the shield, power is shut off before a fire can start.
Fire Shield differ from GFCI's and ground conductors. Grounded conductors only provide a path to ground. GFCI’s detect ground faults. Neither detects the breakdown in the insulation of a standard extension cord, which can lead to an arcing condition that may start a fire. By utilizing a sensing shield around the insulated Fire Shield conductors combined with intelligent electronics in the plug head, Fire Shield can detect damage in the cord such as series faults (broken and frayed conductors) and parallel faults (insulation damage between the live conductors), and shut off the power before a fire can start.
Unintentional misuse of extension cords is the main reason for cord fires. Cords may be crimped, pinched, frayed, overloaded, overheated, or just worn out. Any of these conditions can lead to an extension cord fire. Fire Shield can detect any leakage currents from these conditions and shut off power before a fire can occur.
The cord fire protection is a function of the special shield and relates to the Fire Shield extension cord only.
Fire Shiled should be used anywhere you use standard extension cords or power strips; in children’s rooms, pet areas, with space heaters, electric blankets, waterbeds, etc. Children and pets have been known to bite or chew electrical cords. Fire Shield, with its built-in intelligence may provide protection in these circumstances. Fire Shield Safety Extension Cords should also be used during the holidays with Christmas trees and other holiday decorations because of the tendency to overload extension cords.
Standard surge protectors only provide protection against power surges, which is important. However, standard surge protectors do not provide cord fire prevention. TRC has recently introduced a next generation line of Fire Shield Surge Protectors that not only protects against power surges, but also provides cord fire prevention.
Fire Shield cords are now required at many colleges as the only power strip allowed in college dorms. This is due to students overloading the strips, or tacking the cords to walls or pinching the cords between doors or around corners. All these issues can and will cause fires.
Fire Shield cords are patented and UL/CSA approved.