Friday, May 28, 2021

Southwire TRC 30 Amp GFCIs with Twist Lock Plugs

Southwire  TRC series 44700 and 44720 30 amp GFCIs 

See all of our ground fault circuit interrupters HERE!

30 amp GFCI IN-LINE Cord Sets with Manual Reset.

TRC 30 Amp GFCI's
44700 004-3, 44700 005-2
44720 012-3,  44720 013-2, 44720 020-1
 















Designed for rugged duty. Molded from high impact polymer with booted reset and test buttons. At home in hostile environments such as industrial, construction, maintenance and commercial work sites. Provides compliance with National Electric Code (NEC 2008) Article 590.6 for “Temporary Installations.” Rainproof rated, UL listed for outdoor use. Standard lengths:
2’, 6’, and 25’ with corresponding locking connectors. Custom cable gauges, lengths and terminations available by special order. To prevent unmonitored equipment startup, manual reset is required after GFCI trip and power outage.

44700 004-3 (2’)
44700 005-2 (6’)
• Volts/Amps: 120V/30A • Cord Gauge: 10/3 AWG • NEMA L5-30P & R
• Trip Level: 4 - 6 mA

Southwire's Technology Research Corporation (TRC) GFCI Inline Cord Sets 44700 (120V/30 A)  44720 (240V/30 A) are designed for rugged duty.  Plug and Receptacles are molded from high impact polymer with booted reset and test buttons.  The TRC 44700/44720 series are at home in hostile environments such as industrial, construction, maintenance and commercial work sites. Cord Gauge is 10/3 AWG for maximum strength and durability. Ideal for use by contractors and industrial maintenance personnel working with extension cords or portable tools.  Provides compliance with National Electric Code (NEC 2008) Article 590.6 for Temporary Installations. Applications include: High Pressure Sprayer Washers, Power Tools, Drain Snakes, Pumps, Construction Sites, Industrial Appliances. The TRC GFCI is Rainproof rated, UL listed for outdoor use.  Cord lengths are 2, 6 and 25 feet. The 120 version does not have a 25' length, only 2' and 6'.Voltage rating are 120 and 240 vac, amperage rating is 30, trip level is 4-6mA and has standard 120 or  240 volt NEMA L5 or L6-30 Black Plug & Receptacle. To prevent unmonitored equipment startup, manual reset is required after GFCI trips and power outages or when you unplug and plug back in.

44720 012-3 (3’)
44720 013-2 (6’)
44720 020-1 (25’)
• Volts/Amps: 240V/30A • Cord Gauge: 10/3 AWG • NEMA L6-30P & R

• Trip Level: 4 - 6 mA 

APPLICATIONS INCLUDE 

• High Pressure Sprayer Washers 

• Construction Site Power Tools 

• Drain Snakes

• Pumps

• Industrial Appliances 

• Construction Sites

GROUNDED NEUTRAL   

4 Ohms

TRIP RESPONSE TIME FOR GROUND FAULT 

AND GROUNDED NEUTRAL TRIP  

Less Than 25mS

VOLTAGE SURGE WITHSTAND     

3kv ringwave test and 4kv/2kA surge immunity test

RADIO FREQUENCY NOISE SUSCEPTIBILITY   

Operates Within Normal Limits With 0.5 Volts 

Injected On Power Line 150Khz-230Mhz

FREQUENCY   

60 Hz

ENDURANCE   

3,000 Operations Minimum

OVERLOAD CURRENT   

Six Times Rated Current

OPERATING TEMPERATURE RANGE  

 -35 ̊C to 66 ̊C

EFFECT OF 10 AMP TURN DC SHOCK FAULT TRIP     

5% Maximum Trip Level Variation on Ground 

INSULATION VOLTAGE   

1500 Vrms - 1 Min.

POWER ON INDICATION    

Lighted Indicator 


Anderson-Bolds sells TRC Ground Fault Circuit Interrupters 


Southwire TRC 120 volt 30 amp GFCIs

44700 004-3 (2’)
44700 005-2 (6’)

Southwire TRC 240 volt 30 amp GFCIs

44720 012-3 (3’)
44720 013-2 (6’)
44720 020-1 (25’)


Anderson-Bolds


GFCI...GFCI...GFCI...GFCI...GFCI

Saturday, April 30, 2016

TRC Southwire High Power 100 Amp GFCI - ELCI

Anderson-Bolds sells TRC / Southwire GFCI's and ELCI's up to 100 AMPS.

These are the  new Southwire TRC 24736-001 and 24994-001 100 amp 6-10-30 Trip Level GFCI and ELCI Units.

Anderson-Bolds is your source for Commercial safety products including GFCIs and ELCIs.

GFCIs and ELCIs are used for personnel and equipment protection.


TRC has engineered a new option for the HD-PROTM series called 6.10.30TM.
Configured for both in-line and bulk head mount. This unique new design allows the user to select and lock in the most sensitive trip level at which a specific type of equipment can be operated without nuisance tripping. Adjustable settings
include trip levels for 6mA, 10mA and 30mA. Trip level flexibility to meet your needs in one single device - HD-PROTM with 6.10.30TM.  6.10.30TM key enables trip level selection and locking at a trip level with key removal.  

The GFCIs protect Motors, Pumps, Pressure Washers, Conveyors, Welders and lifts.

Go To GFCI/ELCI Store Page HERE. or call 216-360-9800


TRC 24736-001 and TRC 24994-001
100 amp GFCI/ELCI





















Specifications:

Voltage:  480 or 600 volts AC and three phase
AMPS: 100
Cord Gauge: 2/4 AWG
Trip Levels: 6mA, 10mA, 30mA - chosen by Key Switch
GFCI Response Time: 25mS
Frequency: 50/60 Hz
Endurance: 3,000 operations minimum
Overload Current: SIX times rated current
Temperature Range: -20C to +40C
Power n Indicator: Light
Drop Out Voltage: About 60% rated voltage
Reset Type: Auto
Connection: Flying Leads
Enclosure: NEMA 4 Polymer



216-360-9800
www.anderson-bolds.com