ATC 407C Multi Range Timer (TDR)

Anderson-Bolds Stocks the ATC 407C Time Delay Relay.

ATC is Automatic Timing and Controls (Marshbellowfram)

Model 407C 1/16 DIN Multimode Timer w/Octal Pins

On Delay, Off Delay and Interval Timing Modes.

ATC 407C500 Timer/Time Delay Relay















  • 1/6 DIN multimode timer
  • Selectable On-Delay/Off-Delay/Interval Timing Modes
  • Separate Start Input
  • Output Contacts rated 10A at 120/240 VAC and 30 VDC
  • Six Timing Ranges in a single unit:
    1 and 10 sec., min., and hours
    5 and 50 sec., min., and hours
  • Universal Power Supply; 24-240 VAC and 24 VDC
  • 48mm2 DIN Standard housing
  • Large and easy to read dial shows decimal points
  • Round (octal) socket mount or mount in panel cutout
  • Watertight when panel mounted
  • Range and Mode select are tamper proof when panel mounted
  • Unique flashing cycle progress indication
CE listing and UL recognized

ATC 407C100F3X 1/16 DIN ANALOG SET TDR, Multi-Mode TDR
1 and 10 seconds, 1 and 10 minutes, 1 and 10 and hours  =  6 ranges
BUY HERE

ATC 407C500F3X 1/16 DIN ANALOG SET TDR, Multi-Mode
5 and 50 seconds, 5 and 50 minutes, 5 and 50 and hours  =  6 ranges
BUY HERE

Buy Octal (8 pin) socket for 407C timer HERE


Anderson-Bolds
216-360-9800
sales@anderson-bolds.com

Sunday, August 7, 2011

HD Pro TRC High Power GFCIs and ELCIs


TRC manufacturers High Power Ground Fault and Equipment Fault products for personnel and equipment safety.


Please view the TRC Safety Ground Fault Video Here.


The below series of HDPRO units cover 30 and 60 amps and voltages of 277, 480, and 208-240.

Configured for both in-line and bulk head mount. Engineered to trip within 25 milliseconds. Protects:

�� Motors �� Pumping Systems �� Pressure Washers Has 2’of cable on both line and load side. To prevent equipment startup after

GFCI/ELCI trips,manual reset required. Will reset on power restoration following disruption of primary power. 6.10.30TM key enable strip level selection and locking at a trip level with key removal.


PDF link is Here.


TRC HD-Pro GFCI / ELCI 24396-001

Volts/Amps: 277V/30A

Cord Gauge: 10/3 AWG.

Trip Level: 6, 10 & 30mA

Single Phase


TRC HD-Pro GFCI / ELCI

24672-001

Volts/Amps: 480V/60A

Cord Gauge: 4/4 AWG.

Trip Level: 6, 10 & 30mA

Three Phase


TRC HD-Pro GFCI / ELCI

24542-001

Volts/Amps: 208-240V/60A

Cord Gauge: 4/4 AWG.

Trip Level: 6, 10 & 30mA

Three Phase


TRC HD-Pro GFCI / ELCI

24846-001

Volts/Amps: 208-240V/30A

Cord Gauge: 8/5 AWG.

Trip Level: 6, 10 & 30mA

Three Phase


TRC HD-Pro GFCI / ELCI

24646-001

Volts/Amps: 480V/30A

Cord Gauge: 10/4 AWG.

Trip Level: 6, 10 & 30mA

Three Phase


The below HD Pro models are al 60 amps and come in voltages of 120, 380 and 240.

Configured for both in-line and bulk head mount. Engineered to trip within 25 milliseconds. Protects:

�� Motors �� Pumping Systems �� Pressure Washers Has 2’of cable on both line and load side. To prevent equipment startup after

�� Manufacturing Equipment �� Welders �� Hoists

ELCI trips, manual reset required. Will reset on power restoration following disruption of primary power.


PDF link is here.


TRC HD PRO GFCI / ELCI 24520-001

�� Volts/Amps: 120V/60A �� Cord Gauge: 4/3 AWG. �� Trip Level: 10 mA �� Single Phase


TRC HD-RPO ELCI / GFCI 25560-001

�� Volts/Amps: 380V/60A �� Cord Gauge: 4/4 AWG. �� Trip Level: 30 mA �� Three Phase


TECHNOLOGY RESEARCH CORP HD PRO ELCI / GFCI 24530-001

�� Volts/Amps: 240V/60A �� Cord Gauge: 4/4 AWG. �� Trip Level: 10 mA �� Three Phase



The below TRC HDPRO units are rated 60 amps and 80 amps and have voltages of 208-240, 480 and 600.


PDF link is here.


TRC HD PRO HIGH POWER ELCI / GFIC 24786-001

�� Volts/Amps: 208-240V/80A �� Cord Gauge: 4/4 AWG. �� Trip Level: 6, 10 & 30 mA �� Three Phase


Technology Research HD-PRO ELCI / GFCI 24946-003

�� Volts/Amps: 600V/60A �� Cord Gauge: 4/4 AWG. �� Trip Level: 6, 10 & 30 mA �� Three Phase


HD PRO by TRC High Power GFCI / ELCI 24796-001

�� Volts/Amps: 480V/80A �� Cord Gauge: 4/4 AWG. �� Trip Level: 6, 10 & 30 mA �� Three Phase


HD-PRO TRC High Power GFCI / ELCI 24992-001

�� Volts/Amps: 600V/80A �� Cord Gauge: 4/4 AWG. �� Trip Level: 6, 10 & 30 mA �� Three Phase


The below TRC Units are EGFPDs and are CSA approved. the units are 30 and 60 amps and 208/240 and 480 volts.

EGFPD = Equipment Ground Fault Protection Device


Configured for both in-line and bulk head mount. Engineered to trip within 25 milliseconds. Protects:

�� Motors �� Pumping Systems �� Pressure Washers To prevent equipment startup after EGFPD or GFCI/ELCI trips, manual reset re-

�� Manufacturing Equipment �� Welders �� Hoists

quired. Will reset on power restoration following disruption of primary power. Key en- ables trip level selection and locks at a trip level with key removal.

The PDF file is here.


TRC 44110 EGFPD ( CSA Approved)

�� Volts/Amps: 208-240V/30A �� Trip Level: 10, 30 & 50 mA �� Three Phase


Technology Research Corporation 44140 EGFPD CSA Approved

�� Volts/Amps: 208-240V/60A �� Trip Level: 10, 30 & 50 mA �� Three Phase


TRC 44120 EGFPD ( CSA Approved Device )

�� Volts/Amps: 480V/30A �� Trip Level: 10, 30 & 50 mA �� Three Phase


Technology Research Corp. CSA Approved 44130 EGFPD

�� Volts/Amps: 480V/60A �� Trip Level: 10, 30 & 50 mA �� Three Phase


The below TRC Units are ELCIs and and GFCIs are 30 and 60 amps and 208/240 and 480 volts and have adjustable trip points of 6-10-30 amperes (amps).

Configured for both in-line and bulk head mount. Engineered to trip within 25 milliseconds. Protects:

�� Motors �� Pumping Systems �� Pressure Washers To prevent equipment startup after EGFPD or GFCI/ELCI trips, manual reset re-

�� Manufacturing Equipment �� Welders �� Hoists

quired. Will reset on power restoration following disruption of primary power. Key en- ables trip level selection and locks at a trip level with key removal.

The PDF file is here.


Technology Research Corporation 44610 GFCI/ELCI

�� Volts/Amps: 208-240V/30A �� Trip Level: 6,10 & 30 mA �� Three Phase


TRC 44640 GFCI/ELCI

�� Volts/Amps: 208-240V/60A �� Trip Level: 6,10 & 30 mA �� Three Phase


TRC 44620 GFCI/ELCI

�� Volts/Amps: 480V/30A �� Trip Level: 6,10 & 30 mA �� Three Phase


Technology Research Corp. 44630 GFCI/ELCI

�� Volts/Amps: 480V/60A �� Trip Level: 6,10 & 30 mA �� Three Phase


Our complete list of the HD Pro models by TRC is located here.


To see Anderson-Bolds' other products please go to www.anderson-bolds.com.




TECHNICAL DATA

Friday, January 15, 2010

Heating Cable - Brisk Heat ~ Chromalox

Heating cable is also referred to as heating tape and heat trace cable amongst the industry. Heating cable is used for a wide range of applications including pipe tracing, freeze protection, viscosity control, temperature process maintenance, roof and gutter, and much more. BriskHeat® also offers a true heating tape that is much more flexible and provides a more rapid thermal response.

Self-Regulating / Self-Limiting: Automatically adjusts heat output based on surface temperature. Ideal for freeze protection and low temperature process maintenance. Self regulating heating cable products for freeze protection and process temperature maintenance for a wide range of industrial, commercial and residential applications. These industrial heaters are used to maintain the working temperature of pipes, fittings, valves, tanks and process equipment. Heat Trace cables regulate their heat output in response to changes in temperature.

Constant-Wattage: Provides precise and constant temperatures up to 500oF (260oC). Ideal for a wide range of applications. Constant Wattage Heating Cables are ideally suited for applications where a particular watt density is required at all times. The heater element consists of a nichrome wire wrapped around parallel, insulated buss wires. Constant wattage cables are flexible, can be cut-to- length in the field, and are manufactured for use on voltages from 120 to 480V. Although not suited for overlapping, its constant output makes it an ideal choice for higher temperature applications where higher watt densities are required. Equipped with a ground braid and optional FEP jacket.

CWM 4-1C

CWM 4-1CT

CWM 4-2C

CWM 4-2CT

CWM 8-1C

CWM 8-1CT

CWM 8-2C

CWM 8-2CT

CWM 12-1C

CWM 12-1CT

CWM 12-2C

CWM 12-2CT

CWM 12-4C

CWM 12-4CT

FECAB3120B

FECAB3208B

FECAB3240B

FECAB3277B

FECAB3480B

FECAB3120SS 3 watts/ft; 120V; Stainless Steel Braid

FECAB3208SS 3 watts/ft; 208V; Stainless Steel Braid

FECAB3240SS 3 watts/ft; 240V; Stainless Steel Braid

FECAB3277SS 3 watts/ft; 277V; Stainless Steel Braid

FECAB3480SS 3 watts/ft; 480V; Stainless Steel Braid

FECAB5120B 5 watts/ft; 120V; Tinned Copper Overbraid

FECAB5208B 5 watts/ft; 208V; Tinned Copper Overbraid

FECAB5240B 5 watts/ft; 240V; Tinned Copper Overbraid

FECAB5277B 5 watts/ft; 277V; Tinned Copper Overbraid

FECAB5480B 5 watts/ft; 480V; Tinned Copper Overbraid

FECAB5120SS 5 watts/ft; 120V; Stainless Steel Braid

FECAB5208SS 5 watts/ft; 208V; Stainless Steel Braid

FECAB5240SS 5 watts/ft; 240V; Stainless Steel Braid

FECAB5277SS 5 watts/ft; 277V; Stainless Steel Braid

FECAB5480SS 5 watts/ft; 480V; Stainless Steel Braid

FECAB8120B 8 watts/ft; 120V; Tinned Copper Overbraid

FECAB8208B 8 watts/ft; 208V; Tinned Copper Overbraid

FECAB8240B 8 watts/ft; 240V; Tinned Copper Overbraid

FECAB8277B 8 watts/ft; 277V; Tinned Copper Overbraid

FECAB8480B 8 watts/ft; 480V; Tinned Copper Overbraid

FECAB8120SS 8 watts/ft; 120V; Stainless Steel Braid

FECAB8208SS 8 watts/ft; 208V; Stainless Steel Braid

FECAB8240SS 8 watts/ft; 240V; Stainless Steel Braid

FECAB8277SS 8 watts/ft; 277V; Stainless Steel Braid

FECAB8480SS 8 watts/ft; 480V; Stainless Steel Braid

FECAB12120B 12 watts/ft; 120V; Tinned Copper Overbraid

FECAB12208B 12 watts/ft; 208V; Tinned Copper Overbraid

FECAB12240B 12 watts/ft; 240V; Tinned Copper Overbraid

FECAB12277B 12 watts/ft; 277V; Tinned Copper Overbraid

FECAB12480B 12 watts/ft; 480V; Tinned Copper Overbraid

FECAB12120SS 12 watts/ft; 120V; Stainless Steel Braid

FECAB12208SS 12 watts/ft; 208V; Stainless Steel Braid

FECAB12240SS 12 watts/ft; 240V; Stainless Steel Braid

FECAB12277SS 12 watts/ft; 277V; Stainless Steel Braid

FECAB12480SS 12 watts/ft; 480V; Stainless Steel Braid


Anderson-Bolds Heating cable