Carlo Gavazzi Earth Leakage Monitors

Carlo Gavazzi Earth Leakage (grounding) Monitor Relays

For quotes and information, please go to our Contact Anderson-Bolds page  HERE.


CARLO GAVAZZI is proud to announce the launch of two new Earth Leakage Monitoring Relays, the DEA71 and DEB71. When used in conjunction with a CTG Series Core Balance Current Transformer and appropriate circuit breaker, they provide machine protection against fault currents, and help to reduce fire hazards. These earth leakage relays react to small changes in current which can occur due to insulation or grounding failure.
Two models, each offering choices of threshold ranges, allow users to find the right solution for their unique requirements. The DEA71 features fixed trip levels which offer time-saving installation, with a reliable tripping level and safety against tampering. The DEB71 provides ability to adjust trip levels and includes an adjustable time delay; a lockable front cover provides further tamper protection.
A key advantage offered by DEA71 and DEB71 is avoidance of nuisance tripping in the circuit, in accordance with the EN 60947-2 Annex M norm. Two separate alarm outputs allow for a warning signal to be generated before a shutdown is necessary. Their compact (35mm wide) housing preserves valuable panel space.
The DEA71 and DEB71 from Carlo Gavazzi perform crucial monitoring of earth leakage, prolonging machine life by limiting damage from ground faults as well as reducing fire risk. They conform to global standards such as UL 508, CSA C22.2 and EN 60947-2 Annex M.
The features of the DEA71 and DEB71 Earth Leakage Relays include:
 page1image14184
  •   DEA71 includes two models with fixed trip setting: 30 mA and 300 mA
  •   DEB71 includes two models with adjustable trip levels: 30 mA to 5 A and 300 mA to 30 A
2 SPDT relay outputs, for warning and for alarm 24 VAC to 240 VAC power supply
NORM DIN-rail housing 35 mm
Lockable lid on adjustable models (DEB71)
The DEA71 and DEB71 Monitors and CTG Series Core Balance Current Transformers are available from 

Anderson-Bolds
216-360-9800
www.anderson-bolds.com

Saturday, April 30, 2016

TRC Southwire High Power 100 Amp GFCI - ELCI

Anderson-Bolds sells TRC / Southwire GFCI's and ELCI's up to 100 AMPS.

These are the  new Southwire TRC 24736-001 and 24994-001 100 amp 6-10-30 Trip Level GFCI and ELCI Units.

Anderson-Bolds is your source for Commercial safety products including GFCIs and ELCIs.

GFCIs and ELCIs are used for personnel and equipment protection.


TRC has engineered a new option for the HD-PROTM series called 6.10.30TM.
Configured for both in-line and bulk head mount. This unique new design allows the user to select and lock in the most sensitive trip level at which a specific type of equipment can be operated without nuisance tripping. Adjustable settings
include trip levels for 6mA, 10mA and 30mA. Trip level flexibility to meet your needs in one single device - HD-PROTM with 6.10.30TM.  6.10.30TM key enables trip level selection and locking at a trip level with key removal.  

The GFCIs protect Motors, Pumps, Pressure Washers, Conveyors, Welders and lifts.

Go To GFCI/ELCI Store Page HERE. or call 216-360-9800


TRC 24736-001 and TRC 24994-001
100 amp GFCI/ELCI





















Specifications:

Voltage:  480 or 600 volts AC and three phase
AMPS: 100
Cord Gauge: 2/4 AWG
Trip Levels: 6mA, 10mA, 30mA - chosen by Key Switch
GFCI Response Time: 25mS
Frequency: 50/60 Hz
Endurance: 3,000 operations minimum
Overload Current: SIX times rated current
Temperature Range: -20C to +40C
Power n Indicator: Light
Drop Out Voltage: About 60% rated voltage
Reset Type: Auto
Connection: Flying Leads
Enclosure: NEMA 4 Polymer



216-360-9800
www.anderson-bolds.com





Thursday, April 26, 2012

TRC Coleman Cable GFCI's

Anderson-Bolds Stocks TRC and now Coleman Cable GFCI's and ELCI's.

At present the following are in stock in our warehouse.



TRC GFCI 44720 with 6 ft. cord with twist lock plugs , 120 or 240 volts, 30 amps




TRC GFCI 33120 panel mount GFCI, 120 volts, 20 amps

TRC GFCI 32120 panel mount GFCI, 120 volts and 20 amps



TRC GFCI 14880-037, 120 volt 15 amp GFCI and Strip


TRC and  Coleman Cable also stock a large percentage of their GFCI's and ELCI's.

Some have required package quantities.

Please call Anderson-Bolds to order or click on the links above.

866-360-9810 or email to info@anderson-bolds.com or fill in our request form here.


Sunday, August 7, 2011

HD Pro TRC High Power GFCIs and ELCIs


TRC manufacturers High Power Ground Fault and Equipment Fault products for personnel and equipment safety.


Please view the TRC Safety Ground Fault Video Here.


The below series of HDPRO units cover 30 and 60 amps and voltages of 277, 480, and 208-240.

Configured for both in-line and bulk head mount. Engineered to trip within 25 milliseconds. Protects:

�� Motors �� Pumping Systems �� Pressure Washers Has 2’of cable on both line and load side. To prevent equipment startup after

GFCI/ELCI trips,manual reset required. Will reset on power restoration following disruption of primary power. 6.10.30TM key enable strip level selection and locking at a trip level with key removal.


PDF link is Here.


TRC HD-Pro GFCI / ELCI 24396-001

Volts/Amps: 277V/30A

Cord Gauge: 10/3 AWG.

Trip Level: 6, 10 & 30mA

Single Phase


TRC HD-Pro GFCI / ELCI

24672-001

Volts/Amps: 480V/60A

Cord Gauge: 4/4 AWG.

Trip Level: 6, 10 & 30mA

Three Phase


TRC HD-Pro GFCI / ELCI

24542-001

Volts/Amps: 208-240V/60A

Cord Gauge: 4/4 AWG.

Trip Level: 6, 10 & 30mA

Three Phase


TRC HD-Pro GFCI / ELCI

24846-001

Volts/Amps: 208-240V/30A

Cord Gauge: 8/5 AWG.

Trip Level: 6, 10 & 30mA

Three Phase


TRC HD-Pro GFCI / ELCI

24646-001

Volts/Amps: 480V/30A

Cord Gauge: 10/4 AWG.

Trip Level: 6, 10 & 30mA

Three Phase


The below HD Pro models are al 60 amps and come in voltages of 120, 380 and 240.

Configured for both in-line and bulk head mount. Engineered to trip within 25 milliseconds. Protects:

�� Motors �� Pumping Systems �� Pressure Washers Has 2’of cable on both line and load side. To prevent equipment startup after

�� Manufacturing Equipment �� Welders �� Hoists

ELCI trips, manual reset required. Will reset on power restoration following disruption of primary power.


PDF link is here.


TRC HD PRO GFCI / ELCI 24520-001

�� Volts/Amps: 120V/60A �� Cord Gauge: 4/3 AWG. �� Trip Level: 10 mA �� Single Phase


TRC HD-RPO ELCI / GFCI 25560-001

�� Volts/Amps: 380V/60A �� Cord Gauge: 4/4 AWG. �� Trip Level: 30 mA �� Three Phase


TECHNOLOGY RESEARCH CORP HD PRO ELCI / GFCI 24530-001

�� Volts/Amps: 240V/60A �� Cord Gauge: 4/4 AWG. �� Trip Level: 10 mA �� Three Phase



The below TRC HDPRO units are rated 60 amps and 80 amps and have voltages of 208-240, 480 and 600.


PDF link is here.


TRC HD PRO HIGH POWER ELCI / GFIC 24786-001

�� Volts/Amps: 208-240V/80A �� Cord Gauge: 4/4 AWG. �� Trip Level: 6, 10 & 30 mA �� Three Phase


Technology Research HD-PRO ELCI / GFCI 24946-003

�� Volts/Amps: 600V/60A �� Cord Gauge: 4/4 AWG. �� Trip Level: 6, 10 & 30 mA �� Three Phase


HD PRO by TRC High Power GFCI / ELCI 24796-001

�� Volts/Amps: 480V/80A �� Cord Gauge: 4/4 AWG. �� Trip Level: 6, 10 & 30 mA �� Three Phase


HD-PRO TRC High Power GFCI / ELCI 24992-001

�� Volts/Amps: 600V/80A �� Cord Gauge: 4/4 AWG. �� Trip Level: 6, 10 & 30 mA �� Three Phase


The below TRC Units are EGFPDs and are CSA approved. the units are 30 and 60 amps and 208/240 and 480 volts.

EGFPD = Equipment Ground Fault Protection Device


Configured for both in-line and bulk head mount. Engineered to trip within 25 milliseconds. Protects:

�� Motors �� Pumping Systems �� Pressure Washers To prevent equipment startup after EGFPD or GFCI/ELCI trips, manual reset re-

�� Manufacturing Equipment �� Welders �� Hoists

quired. Will reset on power restoration following disruption of primary power. Key en- ables trip level selection and locks at a trip level with key removal.

The PDF file is here.


TRC 44110 EGFPD ( CSA Approved)

�� Volts/Amps: 208-240V/30A �� Trip Level: 10, 30 & 50 mA �� Three Phase


Technology Research Corporation 44140 EGFPD CSA Approved

�� Volts/Amps: 208-240V/60A �� Trip Level: 10, 30 & 50 mA �� Three Phase


TRC 44120 EGFPD ( CSA Approved Device )

�� Volts/Amps: 480V/30A �� Trip Level: 10, 30 & 50 mA �� Three Phase


Technology Research Corp. CSA Approved 44130 EGFPD

�� Volts/Amps: 480V/60A �� Trip Level: 10, 30 & 50 mA �� Three Phase


The below TRC Units are ELCIs and and GFCIs are 30 and 60 amps and 208/240 and 480 volts and have adjustable trip points of 6-10-30 amperes (amps).

Configured for both in-line and bulk head mount. Engineered to trip within 25 milliseconds. Protects:

�� Motors �� Pumping Systems �� Pressure Washers To prevent equipment startup after EGFPD or GFCI/ELCI trips, manual reset re-

�� Manufacturing Equipment �� Welders �� Hoists

quired. Will reset on power restoration following disruption of primary power. Key en- ables trip level selection and locks at a trip level with key removal.

The PDF file is here.


Technology Research Corporation 44610 GFCI/ELCI

�� Volts/Amps: 208-240V/30A �� Trip Level: 6,10 & 30 mA �� Three Phase


TRC 44640 GFCI/ELCI

�� Volts/Amps: 208-240V/60A �� Trip Level: 6,10 & 30 mA �� Three Phase


TRC 44620 GFCI/ELCI

�� Volts/Amps: 480V/30A �� Trip Level: 6,10 & 30 mA �� Three Phase


Technology Research Corp. 44630 GFCI/ELCI

�� Volts/Amps: 480V/60A �� Trip Level: 6,10 & 30 mA �� Three Phase


Our complete list of the HD Pro models by TRC is located here.


To see Anderson-Bolds' other products please go to www.anderson-bolds.com.




TECHNICAL DATA

Wednesday, June 2, 2010

GFCI vs ELCI




Shock protection for personnel

GFCI Ground Fault Circuit Interrupters


TRC GFCI Product Features
Can provide protection for two, three or four wire circuits
Grounded neutral protection
Open neutral protection
Lighted and/or mechanical trip indicator
Radio frequency interference suppression to protect against nuisance tripping
Trip level 4-6mA
Provides protection in reversed polarity of input line and neutral
Complies with UL & CSA requirements
Available in 120V and 240V with load currents up to 30A


Electrical equipment protection

ELCI Equipment Leakage Current Interrupters


TRC ELCI Products Features
Can provide protection for two, three or four wire circuits
Mechanical trip indicator
Radio frequency interference suppression to protect against nuisance tripping
Trip levels 10mA, 15mA and 20mA
Does not open contacts with loss of primary power
Provides protection in reversed polarity of input line and neutral
Complies with UL & CSA requirements
Available in 120V and 240V with load circuits up to 50A
Special ratings are available