Watlow 1/4 DIN Temperature Controllers

Watlow Process 1/4 DIN Controllers from Anderson-Bolds

The Watlow SERIES F4 1⁄4 DIN temperature process controller offers performance features to meet a wide range of industrial processing needs. The F4 process controller is ideal for semiconductor manufacturing equipment, plastic processing and packaging equipment and industrial process control applications.
The F4 Watlow process controller features a four line, high definition LCD interface display, in addition to an information key that enables easy set up and control operation, minimizing the chance for error. Its 16-bit microprocessor ensures accuracy and delivers performance advantages you can count on from a Watlow controller.
Four digital inputs remotely modify the F4’s operation or enable display of pre-defined operator messages. Advanced process controller features include cascade, ratio, differential, duplex slide wire and retransmit options.
Serial communication and dual alarm relays are included in the base unit. The WATLOW SERIES F4 is packaged with a
NEMA 4X front face to withstand harsh environments anda four-inch (101.6 mm) deep case with removable connectors for wiring convenience. It is manufactured by Watlow, ISO 9001 registered and protected by a three-year warranty.
Use our Watlow Parts form to get a quote.
Watlow F4 Process Controller

Features and Benefits
Guided setup
  • Removes “guess work” from the setup process 
  • Saves time by reducing programming errors 
  • High definition four-line LCD display 
  • Simplifies setup process and operations 
  • Quickly and easily identifies process, alarm and
    set point values 
  • Information “I” Key 
• Displays essential elements from the user manual on board
Customized menuing
  • Quickly displays up to 16 parameters 
  • Allows users to create custom messaging and easily
    identify key events or alarms 
  • High performance 16-bit microprocessor 
  • Provides precise process control with 20Hz update rate on input 1. (10Hz on inputs 2 and 3) 
  • Calibration accuracy of ±0.1 percent of span 
  • Universal input 
  • • Embedded software provides application versatility 
  • • Eliminates the need for dip switches 
  • Modbus® communications ready 

• Equipped to handle RS232 or EIA485 communications
Example Watlow F4P Temperature Controller Part numbers:
F4PH-EEA-01RG - Watlow Process Temperature Controller
Controller with 2 relay outputs and standard control operation.
F4PH-EEB-01RG - Watlow Process Temperature Controller
Controller with 2 relay outputs and enhanced control operation (dual universal inputs, cascade, ratio, duplex, differential, slide wire)
F4PH-FEA-11RG - Watlow Process Temperature Controller
Controller with analog output and a relay output and standard control operation and retransmit analog signal.
F4PH-FEB-11RG - Watlow Process Temperature Controller
Controller with analog output and a relay output and enhanced control operation (dual universal inputs, cascade, ratio, duplex, differential, slide wire) and retransmit analog signal.

The Watlow EZ-ZONE®PM panel mount 1/4 DIN controller offers control options that reduce system complexity and thermal loop ownership cost. It can be ordered as a PID controller, an over/under limit controller or its functions can be combined into an integrated controller. An option to integrate a high amperage power controller output with a high-performance PID controller and an over/under limit controller in one space-saving, panel mount package is also available. Many communications options are offered to support connectivity needs.
Because the Watlow EZ-ZONE PM panel mount controller is highly scalable, you pay only for what is needed. This controller is available in 1⁄32,1⁄16,1⁄8 and1⁄4 DIN panel mount packages. The Watlow EZ-ZONE PM controller is easy to use and is ideal for PID controller, over/under limit controller or integrated controller needs.

Watlow PM EZ-Zone Controllers


Features and Benefits
Integrated PID and limit controller
• Reduces wiring time and termination complexity
compared with connecting discrete products
• Decreases required panel space
• Lowers installation costs
• Increases user and equipment safety for over/under
temperature conditions
High amperage power control output
• Drives 15 ampere resistive loads directly
• Reduces component count
• Decreases cost of ownership
Current monitoring
• Detects heater current flow and provides alarm indication
of a failed output device or heater load
• Drives output on open or shorted heater
Serial communication capabilities
• Provides a wide range of protocol choices including
Modbus(R) RTU, EtherNet/IP™, Modbus(R) TCP, PROFIBUS
DP and DeviceNet™
• Supports network connectivity to a PC or PLC
Dual-channel controller
• Provides two PID controllers in one space-saving package
Enhanced control options
• Easily handles complex process problems such as
cascade, ratio, differential, square-root, motorized valve
control without slidewire feedback, wet-bulb/dry-bulb,
compressor control and peltier loads
Countdown timer option
• Provides batch process control
• Supports set point change during countdown
Advanced PID control algorithm
• Offers TRU-TUNE(R)+ adaptive control to provide tighter
control for demanding applications
• Provides auto-tune for fast, efficient start-up
Configuration communications with software
• Includes Watlow standard bus communications and
EZ-ZONE configurator software
• Saves time and improves reliability of controller setup
Ten-point linearization curve
• Improves sensor accuracy
Built-in sensor compensation curves
• Saves cost of buying compensated sensors
• Includes Vaisala RH and altitude (pressure) curves
Remote set point operation
• Supports convenient set point manipulation from a
remote device such as a master control or PLC
Profile capability
• Offers pre-programmed process control
• Allows ramp/soak programming with 40 total steps,
battery backup and real time clock
Retransmit Output
• Supports industry needs for recording
Factory Mutual (FM) approved over/under limit with
auxiliary outputs
• Increases user and equipment safety for over/under
temperature conditions
Memory for saving and restoring parameter settings
• Decreases service calls and time down
Agency approvals: UL® listed, CSA, CE, RoHS, W.E.E.E.,
FM, SEMI F47-0200, Class 1, Div. 2 rating on selected
models
• Assures prompt product acceptance
• Reduces end product documentation costs
Touch-safe package
• Increases safety for installer/operator
• Complies with IP2X requirements
Consistent termination labeling connection system
• Simplifies switching between products
• Speeds up user’s system documentation
EZ-KEY
• Enables simple, one-touch operation of user-defined,
repetitive activities
Programmable menu system
• Reduces setup time and increases operator efficiency
Three-year warranty

• Provides product support and reliability

Watlow EZ-ZONE PM PM4C1EA-AAAAAAA Integrated PID Digital Display Temperature Control, 1/4 DIN, PID Control, Two 4 digit digital displays, Universal input, 100-240 VAC
Output 1: 5 amp Form C Mechanical Relay

Watlow EZ-ZONE PM PM4C1EJ-AAAAAAA Integrated PID Digital Display Temperature Control, 1/4 DIN, PID Control, Two 4 digit digital displays, Universal input, 100-240 VAC
Output 1: 5 amp Form C Mechanical Relay 
Output 2: 5 amp Form A Mechanical Relay

Watlow EZ-ZONE PM PM4R1EJ-AAAAAAA PID Digital Display Temperature Control, 1/4 DIN, PID Control with RAMP SOAK capability, Two 4 digit digital displays, Universal Sensor input, 100-240 VAC
Output 1: 5 amp Form C Mechanical Relay 
Output 2: 5 amp Form A Mechanical Relay

Watlow EZ-ZONE PM PM4C1EJ-AAEAAAA Integrated PID Digital Display Process/Temperature Control, 1/4 DIN, PID Control, Two 4 digit digital displays, Universal input, 100-240 VAC
Output 1: 5 amp Form C Mechanical Relay 
Output 2: 5 amp Form A Mechanical Relay
Output 3: 5 amp Form C Mechanical Relay

Watlow EZ-ZONE PM PM4C1EJ-AAEKAAA Integrated PID Digital Display Temperature Control, 1/4 DIN, PID Control, Two 4 digit digital displays, Universal Sensor input, 100-240 VAC
Output 1: 5 amp Form C Mechanical Relay 
Output 2: 5 amp Form C Mechanical Relay
Output 3: 5 amp Form C Mechanical Relay
Output 4: SSR Form A, 0.5A

Watlow EZ-ZONE PM PM4C4KH-ALEJAAA Integrated PID Digital Temperature Control, 1/4 DIN, PID Control, Two 4 digit digital displays, Universal input, 20-28 VAC and 12-40 VDC
Output 1: SSR Form A, 0.5A
Output 2: NO-ARC 15 A power control
Output 3: 5 amp Form C Mechanical Relay
Output 4: 5 amp Form A Mechanical Relay

Watlow EZ-ZONE PM PM4C1KK-ALEJAAA Integrated PID Digital Display Temperature Control, 1/4 DIN, PID Control, Two 4 digit digital displays, Universal input, 100-240 VAC
Output 1: SSR Form A, 0.5A
Output 2: SSR Form A, 0.5A
Output 3: 5 amp Form C Mechanical Relay
Output 4: 5 amp Form A Mechanical Relay

Watlow EZ-ZONE PM PM4C4FJ-6AAAAAA Integrated PID Digital Temperature Control, 1/4 DIN, PID Control, Two 4 digit displays, Universal input, 20-28 VAC and 12-40 VDC
Output 1: Universal Process - 4-20mA, 0-10vdc, 0-20mA
Output 2: None
Output 3: None
Output 4: None
Communications: PROFIBUS DP

Watlow EZ-ZONE PM PM4C4FJ-3AAAAAA Integrated PID Digital Display Temperature/Process Control, 1/4 DIN, PID Control, Two 4 digit digital displays, Universal input, 20-28 VAC and 12-40 VDC
Output 1: Universal Process - 0-10vdc, 0-20mA, 4-20mA
Output 2: 5 amp Form A Mechanical Relay
Output 3: None
Output 4: None
Communications: EtherNet/IP/Modbus TCP

For questions/quotes/comments email to wallow@anderson-bolds.com

216-360-9800 / 614-885-3933

Monday, April 28, 2014

Q'Mark Mechanical Artisan Wall Heater

Anderson-Bolds and Q'MARK announce the new Mechanical Artisan Wall HEater

After the release of the Artisan SmartSeries® wall heater last year, Q'Mark has been overwhelmed with the success and thrilled with the performance and beauty of the heater. 

Q'Mark is taking it one step further with the introduction of the new mechanically controlled Artisan wall heater with the same sleek, wavy appearance that shocked the wall heater industry.  There is no other heater in the market that comes close to the unique styling of the Artisan designed wall heater. It is truly a work of art.
Q'Mark has maintained the high quality standard of the Artisan, but now it is controlled with a mechanical thermostat and the heat output can be wired during installation for a lower wattage. 


  • Heater includes an integral thermostat and has the option to make tamper resistant preventing unwanted changes
  • Grille is an aluminum die cast part with closely spaced louvers to discourage insertion of objects
  • USA made design with 2 piece construction
  • Four colors to choose from: Bronze, Navajo White, Aluminum and Northern White
  • Heat wattages up to 4800 watts (240 and 277 volt) 4000 watts on 208 volt and 1800 watts on 120 volt
  • Heating elements carry a 5 year limited warranty with long lasting performance
MCSSAR1802   120 volts  1800/900  watts     6,142 BTU  15 amps
MCSSAR4808   208 volts  4000/2000 watts  13,648 BTU  19.2 amps
MCSSAR4804   240 volts  4800/2400 watts  16,378 BTU  20 amps
MCSSAR4807   277 volts  4800/2400 watts  16,378 BTU  17.3 amps

HTWHSM   Surface Mounting Frame
HTWHS1   1 inch semi-recess Mounting Frame
HTWHS2   2 inch semi-recess Mounting Frame
MCAR2     24V Time-Delay Relay rated 30 amps @ 120- 277V
MCAR12   120V Time Delay Relay rated 30 amps @ 120 - 277V

The standard color is Northern White.  Add BZ, W, AL to part number for the optional colors.

FEATURES
u Save time and money on installation
u The best in contemporary design
u Two piece construction; Includes back box, Element/Fan Deck/Grille
u Built-in tamper resistant thermostat
u Excellent for zone heating - heat where you are, not where you aren’t
u Recess or surface mounting to wall
u Ability to reduce wattage during installation
u Steel finned metal sheath electric heating element provides long service life
u Seamless finish lines and contours, an immediate impression of quality and refinement
u Rugged heavy duty aluminum die cast grille, refined but built to last

u Four colors to choose from: Bronze, Navajo White, Aluminum and Northern White

MOUNTING LIMITATIONS
Do not install heater closer than 12” to the floor, 12” to an adjacent wall, 36” to the ceiling. Do not install heater behind towel rack or door, upside down or sideways, in the floor, in the ceiling, or in closets.


u APPLICATIONS INCLUDE: – Restaurants
– Hotels – Conference Rooms – Atrium – Residential

This new heater integrates well with our other selections of wall heaters by QMark® and are easy to install and even easier for customers to use. 
send emails to qmark@anderson-bolds.com
216-360-9800

www.anderson-bolds.com

Sunday, March 30, 2014

Q'Mark Commercial Baseboard - QMKC


QMKC SERIES ~ Electric Commercial Baseboard by Q'Mark and Anderson-Bolds
Commercial grade construction: 18-gauge front and cover brackets allow heater to withstand rigors of commercial applications. 
Easy installation: Can be installed with minimal disassembly, using mounting holes in rear of cabinet 
Built-in wireway: Facilitates end-to-end installation of continuous-run heaters 
Efficient heat dissipation: "Chimney fin" type element designed for maximum air circulation. Air flow is directed away from walls 
Steel sheathed element: Heating element design combines the durability of a steel tubular heater with the excellent heat transfer characteristics of aluminum fins 
Roomy junction box: Large, identical, pre-wired junction boxes at each end are provided with knockouts in the rear, bottom, inside and outside junction box walls 
Navajo White or Northern White durable textured polyester powder coat finish 



QMKC25126W  2.5 feet  120 volts  500 watts
QMKC25026W  2.5 feet  208 volts  500 watts
QMKC25426W  2.5 feet  240/208 volts  500/376 watts
QMKC25726W  2.5 feet  277/240/208 volts  500/375/282 watts
QMKC2513W    3.0 feet   120 volts  750 watts
QMKC2503W    3.0 feet   208 volts  750 wtts
QMKC2543W    3.0 feet  240/208 volts  750/564 watts
QMKC2573W    3.0 feet  277/240/208 volts  750/564/423 watts
QMKC2514W    4.0 feet  120 volts  1000 watts
QMKC2504W    4.0 feet  208 volts  1000 watts
QMKC2544W    4.0 feet  240/208 volts  1000/752 watts
QMKC2574W    4.0 feet  277/240/208 volts  1000/752/564 watts
QMKC2515W    5.0 feet  120 volts  1250 watts 
QMKC2505W    5.0 feet   208 volts 1250 watts
QMKC2545W    5.0 feet   240/208 volts   1250/940 watts
QMKC2575W    5.0 feet   277/240/208 volts  1250/940/705 watts
QMKC2516W    6.0 feet  120 volts   1500 watts
QMKC2506W    6.0 feet  208 volts   1500 watts
QMKC2546W    6.0 feet  240/208 volts  1500/1128 watts
QMKC2576W    6.0 feet  277/240/208 volts  1500/1128/846 watts
QMKC2508W    8.0 feet  208 volts   2000 watts
QMKC2548W    8.0 feet  240/208 volts   2000/1504 watts
QMKC2578W    8.0 feet  277/240/208 volts  2000/1504/1128 watts
QMKC25008W  12.0 feet  208 volts   2500 watts
QMKC25408W  12.0 feet  240/208 volts  2500/1880
QMKC25708W  12.0 feet  277/240 volts  2500/1880/1410

QMK CBDA2W   2'6" Blank Section
QMK CBDA3W    3' Blank Section
QMK CBDA4W    4' Blank Section
QMK CBDA5W    5' Blank Section
QMK CBDA6W    6' Blank Section
QMK CBDA8W    8' Blank Section
QMK ICAW Inside corner
FS12  1 foot filler section
FS24  2 foot filler section
FS36  3 foot filler section
FS48  4 foot filler section
FSJ2  2 inch Joiner Strip

TA1AW  SINGLE POLE THERMOSTAT, 22 amps
TA1TPAW  Tamper Resistant Single Pole Thermostat
TA2AW  DOUBLE POLE THERMOSTAT, 22 amps
TA2TPAW Tamper Resistant Double Pole Thermostat
HCA121520W 120 volt Load Transfer Switch
HCA241520W 240 volt Load Transfer Switch
RA1W  120 volt DuPlex receptacle
RA1COMPW  Duplex Receptacle cover
DSW2W   Double Pole Disconnect Switch 
PR24  Single Pole Power Relay, 24volt control, 30 amps
PR120  Single Pole Power Relay, 120 volt control, 30 amps
RSA1224  120/24V TRANSFORMER RELAY - 25A
RSA2024  208/24V TRANSFORMER RELAY - 25A
RSA2424  240/24V TRANSFORMER RELAY - 25A
RSA2724  277/24V TRANSFORMER RELAY - 25A


Navajo White or Northern White durable textured
polyester powder coat finish for corrosion resistance. Linear
thermal cut-out shall be factory installed to automatically shut
off heater in event of overheating and reactivate heater when
temperatures return to normal. Raceway cover kit for
providing an enclosed raceway is standard. The complete
heater shall have a height of 6-3/4 (171.5) inches and a
depth of 2-7/8 (73.2) inches. Heaters shall have cULus
approval for mounting on any floor surface including
carpeting.

Heating Element: The heating element wire shall consist
of 80% nickel, 20% chromium, and shall be encased in steel
sheath to assure long and trouble free life. Aluminum fins
shall be so designed as to block sheath radiation to front and
back of heater body and pressure bonded to steel sheath.

Enclosure: The heaters shall be fabricated of minimum
.024 in. steel with minimum .040 in. steel control boxes.
Support brackets shall be .035 in. steel. Junction box
enclosure to have provisions for incoming and outgoing cable
with cable clamp for restraining without additional hardware.
Ground wire pigtail provided in each junction box for
grounding.


email us at qmark@anderson-bolds.com
or call 216-360-9800








Wednesday, April 17, 2013

Q'Mark Zero Clearance Unit Heater - CHPR25


Compact Freeze Protection Unit Heater by Q'Mark and Anderson-Bolds



Use the Anderson-Bolds' HVAC Application Form for Help with your application!

Model CHPR25 is a unique application heater approved for installation in a concealed space, an area between a finished ceiling and drop ceiling, a plenum space, or inside a plenum. It may be installed in areas that are not readily accessible and may be installed for freeze protection.

The Features of the Q'Mark CHPR25 are:

18 ga. all steel casing with neutral grey polyester powder coat finish for corrosion protection
Easy to install using the hanging bracket supplied
Steel finned low watt density element. Fins and elements are arranged in a uniform grid
pattern to assure that all incoming air passes through the heating element.
High limit thermal cutout automatically shuts off current in the event of
overheating and reactivates the heater when temperature returns to normal.
Fan delay control
Optional alarm (240V) to alert automatic thermal limit tripped. Model AFL240
ETL Listed - Control number 9900268
Built-in, heavy duty, contactor/relay
Control Box gasketed to keep out moisture and dust. NEMA 12 construction
Fan motor is totally enclosed, permanently lubricated and thermally protected
Great air throw
Single Point field wiring connection

The Q'Mark CHPR25 is COMPACT 

• Axial fan design allows for smaller unit size
• Dimensions: 12”H X 14”W X 14”L 
• Weight: 26 lbs.
• Standard hanging bracket supplied
• Can also be installed with threaded rod

The Q'Mark CHPR25 has AGENCY APPROVALS 

Model CHPR25 is design certified by ETL to comply with Standard for
Heating and Cooling Equipment ANSI/UL 1995 and CAN/CSA No. 236-05,
third edition. Meets stringent City of Chicago codes for plenum use.

The Q'Mark CHPR25 is ZERO CLEARANCE CAPABLE 

Model CHPR25 is rated for zero clearance to any surface mounted next to the sides, top, and bottom of
the metal cabinet. The rear (entry air) and front (exit air) must have the proper clearances stated in the
installation manual.
Minimum Installation Clearances
SIDES, TOP AND BOTTOM 0 IN.
REAR: 7-3/8 in. (187 mm)
FRONT: 24 in. (610 mm)

The Q'Mark CHPR25 is EFFECTIVE 

• Output: 2500 Watts
• Voltage: 240 1 Phase
• BTUH: 8530 Amps:10.7
• Temp Range: 40°F to 90°F with Positive OFF

The Q'Mark CHPR25 is VERSATILE 

This unit is designed for light commercial and residential use and costs less to operate than larger plenum heaters. It may be installed inside a plenum, plenum space, concealed space between a finished ceiling and drop ceiling or in any open space above a ceiling or below a floor that is used as an air plenum. Perfect for parking garage ceilings, industrial space heating, or crawl spaces.


The Q'Mark chpr25 is rated:

208     /   240 volts
1.9     /   2.5 KW
Single Phase
63987  /   8530  BTUH
130    /  150 CFM
46     /  60 degree rise in temperature
9.42 / 10.7 amps

Q'Mrkk Model CFP25 is designed, tested and Listed by Intertek Testing Services NA, Inc. (ETL/C-ETL Listing Mark) to comply with the following standards:
USA: ANSI/UL 1995 titled “Heating and Cooling Equipment”
Canada: CSA C22.2 No. 236-05, third edition titled “Heating and Cooling Equipment”

This unit is specifically designed and approved for freeze protection installations into a concealed space and other areas not readily accessible. Typical applications include plenums and associated plenum spaces (such as areas above a finished ceiling that contain utilities), crawl spaces, water closets and other concealed locations where freeze protection is required.
Note: rated static pressure is 0.20” sp . This unique heater is provided with a set of normally open contacts that can supply a line voltage signal to an alarm device if desired to provide early notice if for any reason the heater cycles off on its built-in over temperature safety control. This can provide an early notification to allow for repairs BEFORE a freeze up occurs

REPAIR PARTS
1.   Fan Blade           1210-2017-000    Need 1
2.   Time Delay          410171003          Need 1
3.   High Limit            1414-2037-000    Need 1
4.   Motor                  3900-11007-001  Need 1
6    watt unit bearing
5.   Relay                 1414-2038-000     Need 1
6.   Terminal Block   5823-0004-000     Need 1
7.   Thermostat        5813-2091-000    Need 1
8.   Thermostat Knob   3301-2053-000  Need 1
9.   Wire Guard            312056-000     Need 2
10. Element                 302006807

Use the Anderson-Bolds HVAC Application Form for Help with your application!
or call Anderson-Bolds at 216-360-9800.
We handle the Ohio and Kentucky areas for Q'Mark.
email is qmark@anderson-bolds.com

Q'Mark and Marley Engineered Products LIMITED WARRANTY
All products manufactured by Marley Engineered Products are warranted against defects in workmanship and materials for one year from date of installation, except heating elements which are warranted against defects in workmanship and materials for five years from date of installation. This warranty does not apply to damage from accident, misuse, or alteration; nor where the connected voltage is more than 5% above the nameplate voltage; nor to equipment improperly installed or wired or maintained in violation of the product’s installation instructions. All claims for warranty work must be accompanied by proof of the date of installation. The customer shall be responsible for all costs incurred in the removal or reinstallation of products, including labor costs, and shipping costs incurred to return products to Marley Engineered Products Service Center. Within the limitations of this warranty, inoperative units should be returned to the nearest Marley authorized service center or the Marley Engineered Products Service Center, and we will repair or replace, at our option, at no charge to you with return freight paid by Marley. It is agreed that such repair or replacement is the exclusive remedy available from Marley Engineered Products. THE ABOVE WARRANTIES ARE IN LIEU OF ALL OTHER WARRANTIES EXPRESSED OR IMPLIED. AND ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE WHICH EXCEED THE AFORESAID EXPRESSED WARRANTIES ARE HEREBY DISCLAIMED AND EXCLUDED FROM THIS AGREEMENT. MARLEY ENGINEERED PRODUCTS SHALL NOT BE LIABLE FOR CONSEQUENTIAL DAMAGES ARISING WITH RESPECT TO THE PRODUCT, WHETHER BASED UPON NEGLIGENCE, TORT, STRICT LIABILITY, OR CONTRACT. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above exclusion or limitation may not apply to you. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state. For the address of your nearest authorized service center, contact Marley Engineered Products in Bennettsville, SC, USA, at 1-800-642-4328. Merchandise returned to the factory must be accompanied by a return authorization and service identification tag, both available from Marley Engineered Products. When requesting return authorization, include all catalog numbers shown on the products.

216-360-9800

Q'Mark Open Coil Duct Heaters


Open Coil Electric Duct Heaters by Q'Mark




 Q'Mark Open Coil Electric Duct Heaters are custom engineered to customer specification and built to order. They are available UL listed in Slip-in or flanged configurations with heavy gauge galvanized steel frame and terminal box construction. There are also NEMA 12 and NEMA 4 models available. Units include primary and secondary thermal protection and are designed for use with vertical up or horizontal airflow in either direction. Alternate constructions are available for oven heaters, round duct, bottom insert and rain tight installations. Elements are constructed using only the highest A-grade 80/20 nickel-chromium resistance wire with stainless steel terminals. Other optional construction features include recessed, dust tight or insulated terminal box, insulated flanges and protective screens.
A wide assortment of built-in control options are available. Exact, not typical, wiring diagrams are provided with each heater.


u CUSTOM ENGINEERED
u HEAT OUTPUT UP TO 2000KW
u 80/20 A GRADE RESISTANCE WIRE
u VARIETY OF CONSTRUCTION STYLES AND OPTIONS
u MANY CONTROL OPTIONS
u APPLICATIONS INCLUDE: 
– OFFICE BUILDINGS 
– INSTITUTIONS 
– RETAIL STORES 
– PRIMARY HEAT IN AIR HANDLING UNITS 
– AUXILIARY HEAT FOR HEAT PUMPS 

SLIP-IN HEATER
Standard and by far the most widely used because
of the ease of installation. When built-in controls are specified in a slip-in heater, they are usually mounted in the left-hand overhang. If right-hand overhang is desired, specify S dimension to be 1”, T dimension as required.
INSTALLATION
Step 1. Cut hole in side of duct 1/8” larger than heater body.
Step 2. Insert heater until terminal box covers opening.
Step 3. Secure heater in place with sheet metal screws.

FLANGED HEATER (Optional)
Consists of a slip-in heater mounted in a flanged duct section. The slip-in portion slides out without removing flanges from duct. When built-in controls are specified in a flanged heater, they are mounted in the terminal box of the slip-in portion; the frame containing the elements stays the same. The flanged duct section is increased in depth to accommodate the larger terminal box.
INSTALLATION
Step 1. Provide flanges on ends of duct matching heater flanges
Step 2. Secure heater flanges to duct flanges with sheet metal screws, so that mounting screws do not enter terminal box.

Part Number Breakdown

OPEN COIL DESIGNATION 
OF Flanged (>81°F Inlet Air) 
OG Flanged (80°F Max Inlet Air) 
OS Slip-In (>81°F Inlet Air) 
OT Slip-In (80°F Max Inlet Air) 
OW Outdoor 
ORS Round Duct (>81°F IA) 
ORT Round Duct >80°F max IA) 
OAF Alt. Flange Slip-In (>81°F IA) 
OAG Alt. Flange Slip-In (80°F max IA) 

MEP VOLTAGE DESIGNATION 
(CONTROL VOLTAGE TO THE UNIT) 
1 24V, 1Ø 
2 120V, 1Ø 
3 208V, 1Ø 
4 240V, 1Ø 
5 277V, 1Ø 

MEP VOLTAGE DESIGNATION 
(SUPPLY VOLTAGE TO THE UNIT & CONTROL VOLTAGE) 
01 24V, 1Ø 
02 120V, 1Ø 
03 208V, 1Ø 
04 208V, 3Ø 
05 240V, 1Ø 
06 240V, 3Ø 
07 277V, 1Ø 
08 480V, 3Ø, 3-wire 
09 480V, 3Ø, 4-wire 

MEP STANDARD CONTROL PACKAGES (SEE CONTROLS BROCHURE FOR PACKAGE DETAILS) 
1 Contains a de-energizing magnetic operating contactor, fuses (heaters > 48 amps), & line-voltage to 24V control transformer. 
2 Contains a de-energizing magnetic operating contactor, fuses (heaters > 48 amps), a line-voltage to 24V control transformer with primary fuses, & electronic step control. 
3 Contains a de-energizing magnetic safety contactor, a de-energizing magnetic operating contactor per step, fuses (heaters > 48 amps), SCR control, SCR Vernier System, & line-voltage to 24V control transformer. 
4 Contains a de-energizing magnetic safety contactor, fuses (heaters > 48 amps), SCR control & line-voltage to 24V control transformer. 
0 Not a standard control package - user defined. 

To calculate the amount of heat required in Kilowatts (KW), knowing the volume of airflow in cubic feet per minute (CFM) and the temperature rise is in degrees Fahrenheit (ΔT) that is required for the application, the required kilowatt (KW) rating of the heater can be determined from the formula:  KW = (CFM x ΔT)/3160

Supply Wire & Terminal Sizing
UL requires the line terminals in duct heaters be sized to accept conductors which are rated to carry at least 125% of heater line cur- rent. Heaters are provided with properly sized terminals at no extra charge. Field supply wires must be sized to carry at least 125% of heater line current except when the heater is for space heating, is over 50 KW, and not more than 3 wires in the conduit. Under those conditions the conductors may be sized at 100% of the heater line current. Supply conductors must have insulation rated at 75°C (167°F) or higher.


Open Coil Duct Heaters 
Open Coil Duct Heaters utilize the highest grade resistance wire in the manufacturing process. An iron-free, 80% nickel and 20% chromium wire has a lower operating temperature, a higher corrosion resistance, less resistance change, less sag, and a longer life expectancy than other commonly used resistance wires. 
For most simple space heating applications, open coil models are a good choice. Open coil models tend to be lower KW and smaller in size than a finned tubular unit. Some of the advantages of an open coil model are: 
• Element Temperature – The open coil element releases its heat directly into the airstream. As a result, the open coil runs cooler than the coil in the finned tubular element which is isolated from the air by insulation and a metal sheath. Because the heat is going directly into the airstream, the duct heats up quicker. 
• Low Pressure Drop – Because of the high percentage of open space across the heater, open coil heaters have very low pressure drop as compared to finned tubular heaters. This can result in reduced fan motor horsepower and makes it possible to retrofit open coil heaters into existing systems without changing the fan motor 
• Large Electrical Clearances – Generous electrical clearances between the coil and frame enable open coil heaters to withstand severe applications such as subway car heating, where voltages may exceed 750 volts. 
• Smaller Size – It is normally possible to get a higher KW with open coil construction for a given face area. 

Q'Mark Open Coil Duct Heaters are UL listed in the USA.

Q'Mark Open Coil Duct heaters are Made in the USA.

Call Anderson-Bolds for more information or for the Ohio or Kentucky wholesaler nearest your location.
216-360-9800 or 513-528-5680