Showing posts with label Heater. Show all posts
Showing posts with label Heater. Show all posts

Wednesday, June 9, 2021

Q'Mark In Floor Unit Heater Model THX

 Q'Mark THX in floor convector Heater from Marley

In-Floor Convector - THX Series

For Information Contact Anderson-Bolds HERE!

THE OUT-OF-SIGHT, OUT-OF-MIND, UL LISTED IN-FLOOR PERIMETER TRENCH HEATER
THX zero vertical profile eliminates visual disruptions while preserving the building’s heat envelope and amplifying building aesthetics. Maximize building comfort and reclaim floor space with the most compact, in-floor convector on the market today.

Brought to you by Marley Engineered Products—a trusted leader in comfort solutions—THX is designed with durability in mind to withstand daily cleaning, water and debris. 

IDEAL SPACES | 
      Conference rooms, Hallways, Lobbies & Offices

Convector Heater for In-Floor Installations
Q'Mark / Marley






PRODUCT INNOVATIONS AND KEY FEATURES |

      Maximize Building Comfort
      THX directly addresses the building's need for supplemental heat against the curtain walls and glazing, while fully integrating with the architects' designed interior spaces. Whether you are starting a new building project or adding to an existing spec, count on the THX to deliver desired performance through unique features and flexible installation options. From design to installation and servicing, the THX is built to be quickly, easily installed and maintained in order to provide the superior comfort solutions your client demands.

      Product Innovations

  • Maintain the building’s heat envelope
  • UL listed out-of-the-box with sealed j-boxes
  • Maximum performance but hidden

      Key Features

  • Easy extensibility
  • Easy mounting
  • Easy installation & maintenance
  • Invisible heat source
  • Rated for high traffic areas

TECHNICAL SPECIFICATIONS |
      Grille Colors

      White, Aluminum & Black

      Grille Types

      Flush or Surface

      Cabinet/Enclosure

  • 16-gauge galvanneal steel enclosure
  • 1/2" and 3/4" electrical knockouts on each end, side and bottom

      Size

  • Low profile 6 1/3" wide by 7 7/8" deep
  • Available in lengths 2' to 5'
  • Standard unit connection kit for lengths beyond 5 ft.

      Heating Volume & Outputs

  • Single phase, 208V, 240V and 277V models available
  • 188 or 250 watts per foot

      Heating Elements

  • Nickle-Chromium wire heating element encased in steel sheath with aluminum fins (standard)
  • Stainless steel heating element with aluminum fins (optional)

      Wiring & Electrical

  • UL Listed with sealed junction boxes
  • All controls included in unit so no need for additional control boxes
  • End connection points and wire-way
  • Dual safety limit chain with both manual and automatic reset

      Water & Debris Management

  • Debris catch screen included
  • UL Listed for water management
  • Elements and connection points are raised off the floor

      Optional Built-In Controls

  • On/Off Switch: for easy and safe servicing
  • Power Relay: for BMS connections
  • Transformer Relay: for remote wall thermostat


THXQ 02188 - 2Ft, 188 watts/Ft., 376 watts, 208, 240, 277 voltages, 30 pounds

THXQ 02250 - 2Ft, 250 watts/Ft., 500 watts, 208, 240, 277 voltages, 30 pounds

THXQ 03188 - 3Ft, 188 watts/Ft., 564 watts, 208, 240, 277 voltages, 40 pounds

THXQ 03250 - 3Ft, 250 watts/Ft., 750 watts, 208, 240, 277 voltages, 40 pounds

THXQ 04188 - 4Ft, 188 watts/Ft., 752 watts, 208, 240, 277 voltages, 52 pounds

THXQ 04250 - 4Ft, 250 watts/Ft., 1000 watts, 208, 240, 277 voltages, 52 pounds

THXQ 05188 - 5Ft, 188 watts/Ft., 940 watts, 208, 240, 277 voltages, 60 pounds

THXQ 05250 - 5Ft, 250 watts/Ft., 1250 watts, 208, 240, 277 voltages, 60 pounds


email to:  qmark@anderson-bolds.com


Anderson-Bolds
216-360-9800
www.anderson-bolds.com

Sunday, December 13, 2020

Watlow PM PLUS™ PID & Integrated Limit Controllers

Watlow PM PLUS controllers from Watlow 
and Anderson-Bolds

Watlow’s PM PLUS™, the enhanced EZ-ZONE® PM, is now more intuitive and features an enhanced interface for easier programming and readability with a SMOOTH-TOUCH™ keypad creating an industry leading user experience. The Watlow PM PLUS is backwards compatible with legacy EZ-ZONE PM controllers but offers many user upgrades including an intuitive menu flow allowing the controller to be easily configured. It also continues to offer the industry leading Bluetooth® connectivity with the EZ-LINK™ mobile app for remote access capability and full descriptions of parameters and error codes. The PM PLUS improves the user experience by reducing the complexity at the front of the control while eliminating the dependency of cables when configuring the product.

Like the original Watlow EZ-ZONE PM, the PM PLUS can be ordered as a PID controller, or an integrated controller with multiple functions combined into one. Now Watlow’s PM PLUS is available through Watlow SELECT®, a program that enables you to quickly identify, configure and receive your thermal products faster and easier than ever before. With SELECT, you use a variety of tools to guide your decision, configure products for an exact fit and quickly receive your order. 


For a Watlow PM-PLUS quote, Please click HERE!

Watlow PM-PLUS Temperature Controller










Features and Benefits 

Intuitive menu flow • Reduces menu structure to a list of lists allowing the controller to be easily configured • Offers easy to read characters and color coding making the display visible from many angles 

SMOOTH TOUCH keypad • Eliminates contamination points on the front of the controller • No mechanical components will wear out • Creates a better seal on front panel • Easy to clean

Bluetooth® compatible with EZ-LINK™ mobile app • Provides full descriptions of parameters and error codes • Allows remote access capabilities without the use of cables or converters • Provides the ability to configure the product and save parameter sets 

Integrated PID and limit controller • Reduces wiring time and termination complexity compared with connecting discrete products • Decreases required panel space • Lowers installation costs • Increases user and equipment safety for over/under temperature conditions 

High amperage power control output • Drives 15 ampere resistive loads directly • Reduces component count • Decreases cost of ownership 

Current monitoring • Detects heater current flow and provides alarm indication of a failed output device or heater load • Drives output on open or shorted heater 

Serial communication capabilities • Provides a wide range of protocol choices including Modbus® RTU, EtherNet/IP™, Modbus® TCP, PROFIBUS DP, DeviceNet™ and J1939 CAN bus • Supports network connectivity to a PC or PLC 

Enhanced control options • Easily handles complex process problems such as ratio, differential, square-root, motorized valve control without slidewire feedback, wet-bulb/dry-bulb, compressor control and peltier loads

Countdown timer option • Provides batch process control • Supports set point change during countdown 10-point linearization curve • Improves sensor accuracy 

EZ-LINK™ mobile application for iPhone® and Android™ • Expedites controller setup with intuitive navigation • Simplifies setting parameters with plain text names and descriptions • Connects quickly and easily via Bluetooth® wireless communications 

Configuration communications with software • Includes Watlow standard bus communications used by COMPOSER® or EZ-ZONE configurator software 

Advanced PID control algorithm • Offers TRU-TUNE®+ adaptive control to provide tighter control for demanding applications • Provides auto-tune for fast, efficient start-up 

Built-in sensor compensation curves • Saves cost of buying compensated sensors • Includes Vaisala RH and altitude (pressure) curves 

Remote set point operation • Supports convenient set point manipulation from a remote device such as a master control or PLC 

Profile capability • Offers pre-programmed process control • Allows ramp/soak programming with 40 total steps 

Retransmit output • Supports industry needs for recording 

Factory Mutual (FM) approved over/under limit with auxiliary outputs • Increases user and equipment safety for over/under temperature conditions 

Memory for saving and restoring parameter settings • Decreases service calls and time down 

Agency approvals: UL® listed, CSA, CE, RoHS, W.E.E.E., FM, SEMI F47-0200, Class 1, Div. 2 rating on selected models • Assures prompt product acceptance • Reduces end product documentation costs

Touch-safe package • Increases safety for installer/operator • Complies with IP2X requirements

Programmable function key • Enables simple, one-touch operation of user-defined, repetitive activities 

Programmable menu system • Reduces setup time and increases operator efficiency 

Three-year warranty • Provides product support and reliability

Watlow PM-PLUS Controller 











For a Watlow PM-PLUS quote, Please click HERE!

Specifications:

Controller • User-selectable heat/cool, on-off, P, PI, PD, PID or alarm action • Auto-tune with TRU-TUNE+ adaptive control algorithm • Control sampling rates: input = 10Hz, outputs = 10Hz 

Profile Ramp/Soak • 4 profiles, 40 total steps • Accuracy (typical): ±30 PPM at 77°F (25°C) +30/-100 PPM at -4 to 149°F (-20 to 65°C) 

Isolated Serial Communications • EIA 232/485, Modbus® RTU • EtherNet/IP™/Modbus® TCP • DeviceNet™ • PROFIBUS DP • SAE J1939 CAN bus 

Wiring Termination—Touch-Safe Terminals • Input, power and controller output terminals are touch safe, removable, 12 to 22 AWG 

Universal Input • Thermocouple, grounded or ungrounded sensors greater than 20MΩ input impedance, 3µA open sensor detection, 2kΩ source resistance max. • RTD 2- or 3-wire, platinum, 100Ω and 1000Ω @ 32°F (0°C) calibration to DIN curve (0.00385 Ω/Ω/°C) • Process, 0-20mA @ 100Ω, or 0-10VDC @ 20kΩ, 0-50mV at 20MΩ, 0-1000Ω potentiometer; scalable; inverse scaling 

Functional Operating Range Type J: -346 to 2192°F (-210 to 1200°C) 

Type K: -454 to 2500°F (-270 to 1371°C) 

Type T: -454 to 750°F (-270 to 400°C) 

Type E: -454 to 1832°F (-270 to 1000°C) 

Type N: -454 to 2372°F (-270 to 1300°C) 

Type C: 32 to 4200°F (0 to 2315°C) 

Type D: 32 to 4200°F (0 to 2315°C) 

Type F: 32 to 2449°F (0 to 1343°C) 

Type R: -58 to 3214°F (-50 to 1767°C) 

Type S: -58 to 3214°F (-50 to 1767°C) 

Type B: 32 to 3300°F (0 to 1816°C) 

RTD (DIN): -328 to 1472°F (-200 to 800°C) Process: -1999 to 9999 units 

Accuracy • Calibration accuracy and sensor conformity: ±0.1% of span, ±1°C @ the calibrated ambient temperature and rated line voltage • Types R, S, B; 0.2% • Type T below -50°C; 0.2% • Calibration ambient temperature @ 77°F ±5°F (25°C ±3°C) • Accuracy span: 1000°F (540°C) min. • Temperature stability: ±0.1°F/°F (±0.1°C/°C) rise in ambient max. 

Thermistor Input • 0 to 40kΩ, 0 to 20kΩ, 0 to 10kΩ, 0 to 5kΩ • 2.252kΩ and 10kΩ base at 77°F (25°C) • Linearization curves built-in

Current Transformer Input • Accepts 0-50mA signal (user-programmable range) • Displayed operating range and resolution can be scaled and are user-programmable 

Digital Inputs (DC Voltage) • Max. input: 36V at 3mA • Logic: min. high state 3V at 0.25mA, max. low state 2V 

Digital Inputs (Dry Contact) • Logic: min. open resistance 10kΩ, max. closed resistance 50Ω • Max. short circuit: 20mA 

2 Digital I/O (ordered with power supply option) • Update rate: 10Hz • Input type: user-selectable, dc voltage or dry contact • Output type: switched dc • Output voltage: 24V • Output 5: 24mA max. or drive one 3-pole DIN-A-MITE® • Output 6: 10mA max. 

Output Hardware • Switched dc: 22 to 32VDC @ 30mA max. per single output and 40mA max. total per paired outputs (1 & 2, 3 & 4) 

• Open collector: 30VDC max. @ 100mA max. 

• SSR, Form A, 24 to 240VAC, 1A at 50°F (10°C) to 0.5A at 149°F (65°C) resistive load, 264VAC max., opto-isolated, without contact suppression, 120/240VAC @ 20VA pilot duty 

• Electromechanical relay, Form A, 24 to 240VAC or 30VDC max., 5A resistive load, 100,000 cycles at rated load, 120/240 @ 125VA or 24VAC @ 25VA pilot duty 

• Electromechanical relay, Form C, 24 to 240VAC or 30VDC max., 5A resistive load, 100,000 cycles at rated load, 120/240 @ 125VA or 24VAC @ 25VA pilot duty 

• NO-ARC relay, Form A, 85 to 264VAC, 15A @ 122°F (50°C), resistive load, no VDC, 2,000,000 cycles at rated load 

• Universal process output: range selectable; 0 to 10VDC ±15mV into a min. 1,000Ω load with 2.5mV nominal resolution; 0 to 20mA ±30μA into max. 800Ω load with 5μA nominal resolution; temperature stability 100ppm/°C

Operator Interface • LCD display • SMOOTH TOUCH keypad • Programmable function key

Line Voltage/Power • High voltage option: 85 to 264VAC, 47 to 63Hz • Low voltage option: 20 to 28VAC, +10/-15%; 50/60Hz, ±5% or 12 to 40VDC • Max. power consumption: 10VA (1/32 and 1/16 DIN); 14VA 

Environment • Operating temperature: 0 to 149°F (-18 to 65°C) • Storage temperature: -40 to 185°F (-40 to 85°C) • Relative humidity: 0 to 90% RH, non-condensing 

Agency Approvals • cULus® UL®/EN/CSA C22.2 No 61010-1 Listed, File E185611 • CSA C22.2 No. 24, File 158031 (1/32 and 1/16 DIN sizes) • IP 67, IP 66 front seal • UL® Type 4X front seal indoor locations • cULus® ANSI/ISA 12.12.01-2012, CSA-C22.2 No. 213-1987, Class 1, Div. 2, Groups A, B, C and D, Temperature Code T4A, File E184390 (optional) • FM Class 3545 (limit controls) • CE, RoHS by design, W.E.E.E. • EtherNet/IP™ and DeviceNet™ ODVA Conformance Tested displays

For a Watlow PM-PLUS quote, Please click HERE!

Anderson-Bolds
Cleveland, Ohio
www.anderson-bolds.com
216-360-9800

Monday, March 30, 2020

RAYMAX from Watlow

RAYMAX® 1220 and 2030 Panel Heaters from Anderson-Bolds


for a quote please email to watlow@anderson-bolds.com
or use our WATLOW form HERE!

 Ideal For Many Process Heating Applications Requiring “Hot Face” Temperatures

The Raymax Panel heater product line from Watlow solves virtually an application requiring radiant heat from a contamination resistant surfaces to fast responding high temperature needs.

Watlow Raymax Radient Panel


Maximum face temperature up to 2000ºF

Typical applications are:
Thermoforming
Food warming
Paint and epoxy curing
Heat treating
High temperature Furnaces
Tempering and annealing processes




Raymax 1010
1000ºF Face Temperature

The Ryamax 1010 is the ideal for use in screen printing, food warming and other low heat applications. The Heater's "sealed face" keeps contaminates away from the heating element, and the metal surface can be easily wiped or brushed clean whenever needed.
Uniform full surface heat source
Convenient ready to use package
One inch thick backside insulation
Repeatable temperature sensing options
UL: component listing.

Heater width is from 4-20 inches
Heater Length is from 10 to 68 inches
voltage up to 480 vac
Watt Density is 10W/sq. inch
 Easy to install and capable of high surface temperatures,
the RAYMAX® 1220 and 2030 are ideal for many process
heating applications requiring “hot-face” temperatures
above 1000°F (540°C).
Each ceramic fiber heater is mounted in a 212 in. (64 mm)
deep sheet metal case providing thermal insulation. The case
includes post terminals for electrical connections and
provides a mounting system that can be used with virtually
any flat ceramic fiber unit. Watt density and temperature
capabilities can be tailored to meet a specific radiant
application for exposed sinuated embedded coil or foil
element configuration.

Performance Capabilities
RAYMAX 2030 (uses sinuated or coil elements):temperatures up to 2000°F (1095°C); watt densitiesup to 30 W/in2 (4.7 W/cm2)
RAYMAX 1220 (uses an etched foil element):temperatures up to 1200°F (650°C); watt densitiesup to 20 W/in2 (3 W/cm2)
Maximum voltage up to 600V

Features and Benefits
Lightweight, low mass design
Allows fast response to controllers
Self insulation with 21/2 in. (64 mm ) thick mounting case
Provides high efficiency
Thermocouple mounting clamp
Simplifies process system control
Aluminized steel case
Handles temperatures up to 1100°F (595°C)
Special hot-face heating patterns
Designed specifically for an application using an etched foil RAYMAX 1220

Specifications 
Weight: Less than 6.5 lbs/ft2 (31.75 kg/m2
Voltage and Wattage: Ratings, up to 600VAC are based on 
the ceramic fiber heater module mounted in the case. 
Terminals: Terminals are 14-20 threaded studs. Two terminals 
plus ground for single-phase, and three terminals plus ground 
for 3-phase are located on the center length line unless 
otherwise specified. Terminals can be positioned anywhere 
along lines A and B (see illustration below), but not closer 
than 2 in. (51 mm) to the case ends. 
Mounting Legs: Mounting legs are available either 
1 in. (25 mm) or 3 in. (76 mm) length. For made-to-order units, 
mounting legs can be supplied in any incremental length L 
from 12 in. (13 mm) to 3 in. (76 mm). Slots are not provided in 
legs less than 1 in. (25 mm) long. 

Application Hints 
A thermocouple mounting clamp is attached to one end of 
the case, with holes on both ends for alternate locations. 
The clamp can be used with 18 in. (3.2 mm) O.D. sheath 
thermocouples. The clamp is 3/16 in. (4.8 mm) high, but 
can be removed for flush mounting*. 
The maximum recommended surface temperature of the 
heater is based on the rating of the ceramic fiber heater 
module. This can vary from 2000°F (1095°C) at lower watt 
densities, to higher watt densities at reduced surface 
temperatures. Note: maximum wattages cannot be achieved 
at the maximum temperatures simultaneously. 
* 1316 in. (4.8 mm) and 14 in. (6 mm) are available upon request. 

Options 
Several options are available with RAYMAX 1220 and 2030 
models. Contact your Watlow representative for more 
information. 
• Single-phase non-standard location power terminals 
• Terminal box 
• Zoning 
• Mounting studs and legs 
• 3-phase construction 
• Thermocouple mounting tubes 
• Alternate case materials 

RAYMAX 2030 PART NUMBERS
VP504A06T, VP504A12T, VP504A18T, VP504A24T, VP504A30T, VP504A36T
VP506A06T, VP506A12T, VP506A18T, VP506A24T, VP506A30T, VP506A36T
VP508A06T, VP508A12T, VP508A18T, VP508A24T, VP508A30T, VP508A36T
VP510A06T, VP510A12T, VP510A18T, VP510A24T, VP510A30T, VP510A36T
VP510A06T, VP510A12T, VP510A18T, VP510A24T, VP510A30T, VP510A36T
VP512A06T, VP512A12T, VP512A18T, VP512A24T, VP512A30T, VP512A36T
VP514A06T, VP514A12T, VP514A18T, VP514A24T, VP514A30T, VP514A36T
VP516A06T, VP516A12T, VP516A18T, VP516A24T, VP516A30T, VP516A36T


Anderson-Bolds
216-360-9800