Wednesday, December 2, 2020

TRC Electra Check Power Monitor

 TRC/Southwire Digital Power Monitor AECM20020


The TRC Electra Check (AECM20020) is a compact, easy to use instrument is made with advanced microelectronics and provides accurate testing and monitoring of electrical outlets and systems.  Constantly monitors voltage and frequency indicating potential improper polarity and ground wiring.  Its small size and rugged construction allows for convenient installation in an electrical outlet or use as a portable service tool.

Voltage is measured as RMS which is much more precise than AC average.  RMS metering is the only method that can accurately measure all AC power sources.  The RMS voltage and frequency readings are ideal for monitoring modified sine waves such as solid-state generators, inverters and Uninterruptible Power Supply (UPS) products.

The Digital Monitor display will alternate between line voltage in RMS volts and line frequency in Hertz. The LCD display shows an F in front of the reading to denote frequency. Pressing the MODE button on the front of the Digital Monitor will cycle through the display modes. Both voltage and frequency are constantly monitored regardless of the display mode.

Fully tests incoming power for: Open ground, Reverse polarity,High/Low voltage. Three display modes available: Alternating voltage and frequency (VOLT/FREQ.), Voltage only (VOLTAGE), Frequency only (FREQUENCY)

Electra Check is about 2x3 inches. The TRC part number is AECM20020.

TRC AECM20020-3-012 Electra Check Digital Monitor for All AC Power Sources, Black with White Face











Anderson-Bolds
216-360-9800
www.anderson-bolds.com

Tuesday, December 1, 2020

GFCI's and OSHA Violations

 GFCI Products to Remedy OSHA Violations

TRC GFCI 14650-006







An OSHA violation is a serious matter. Many of them can result in injury or death. Some violations are obvious and easy to spot while others require training and a comprehensive understanding of the requirements in order to detect them.

For example, improper Lockout/Tagout of energized equipment or machine guarding, although not simple, might be easier to notice and correct than electrical code violations that require a detailed understanding of the written rules and are likely to be unnoticed by many at the site.

Although most of the people understand basic electricity (e.g., not sticking metal objects into outlets,  it is still perceived as a very complicated topic.

However, not all electrical violations are complicated. Some basic OSHA-mandated safety requirements are very easy to spot and correct if one knows what to look for. Among the top ten most frequently cited standards violations for 2014-2015, electrical-related standards violations are number 8 and 10 on the list.


Top 10 Most Frequently Cited Standards violations for Fiscal 2015 (Oct. 1, 2014, to Sept. 30, 2015)

1.       Fall Protection (1926.501)

2.       Hazard Communication (1910.1200)

3.       Scaffolding (1926.451)

4.       Respiratory Protection (1910.134)

5.       Lockout/Tag Out (1910.147)

6.       Powered Industrial Trucks (1910.178)

7.       Ladders (1926.1053)

8.       Electrical – Wiring Methods (1910.305)

9.       Machine Guarding (1910.212)

10.     Electrical – General Requirements (1910.303)


Anderson-Bolds can help with Fall Protection, Lockout/Tag Out,

 Machine Guarding and Electrical (GFCIs).


30 Amp Inline GFCI with locking plugs





Now we are unlikely to be able to educate everyone on everything, but what we can achieve is to give some basic ideas on how these violations can be decreased and potentially save lives. If, as a result of this article, we save one life we could not be happier and it is sad to see people getting injured for something that is so easy to avoid.

So what exactly is so easy to fix? Use a work site Ground Fault Circuit Interrupter or GFCI for short! If you have employees working in a location that has temporary power, it is highly recommended to use a GFCI on every electrical circuit or service, even if there are no OSHA regulations requiring it.

For example , with the use of tools like wet vacs, power washers, wet saws or drills used to mix cement, it is a good practice to have GFCI’s installed to protect employees who work with this equipment. Per OSHA, all construction sites and construction site-like activities that use extension cords or certain equipment have to be GFCI protected2. As a rule of thumb, if you have power equipment outdoors, or near moisture/water you need to use GFCI-protected devices. OSHA estimates that since the GFCI requirement was implemented in 1970, the rule has saved more than 650 lives. That is one person a month since 1970!  

What is a GFCI? (Ground Fault Circuit Interrupter)

GFCI is an electrical device that measures the difference between output and input load current, opening whenever a difference is detected that could pose a safety hazard. If there is a current difference of more than 6 milliamps (mA), the GFCI unit will disconnect power to the load. Don’t be fooled into using a standard circuit breaker. Circuit breakers are designed to protect equipment not people!

GFCI’s come in a variety of forms and shapes, but for MRO or construction industries, the two most common options are right angle plug adapters or corded GFCIs that have a power cord and multiple output sockets. Each type might come with various additional features, especially the corded models. Corded models can offer different cord lengths from 2 ft up to 100 ft long, and also illuminated outlets and various socket configurations.

Something to remember is that socket multipliers and surge protectors are not the same as a Ground Fault Circuit Interrupter or GFCI for short. A GFCI is the only device designed specifically to protect people, whereas everything else is designed to protect equipment from damage due to high voltage transients. This is important to remember in order to choose the appropriate device for its intended application. If you have a device and you want to protect equipment from damaging power transients, then use a surge protector. However, if your primary concern is to protect employees, a GFCI is the only product capable of doing it.

A properly designed and manufactured GFCI unit will continue to provide protection when hazardous wiring conditions present. For example mis-wiring the neutral wire and a hot wire at the circuit breaker or outlet will not impede the GFCI’s ability to offer protection.

There are certain circumstances when a GFCI might not prevent a shock, such as when a person touches  both electric wires at the same time, offering a path from one wire in through one hand, through the body, and out on the other hand to the other electric wire. In this situation the GFCI will not sense a current imbalance and will not trip. This is a very important point to consider when training personnel working on equipment with GFCIs.

GFCI’s are intended to trip if current is passing through a path to ground; this could be from a tool or piece of equipment through the user. The GFCI is intended to trip quickly, so the user is not harmed.

It should be noted that a shock can be felt even with a GFCI, but the GFCI will trip quickly enough to avoid an injury.

When looking for a GFCI something to keep in mind is the design of the product. Although there are a lot of products available on the market, the most reliable products carry a UL approval. UL is the leading safety organization with best test and follow up practices. This ensures products are produced with safety critical aspects continually tested and validated in the factory. You might find some products that are few dollars cheaper, but do not carry UL approval and they may perform just as well. The key here is “may”. Products that have UL approval have undergone the most rigorous testing and follow up inspection, and so it should be the “product of choice” when personnel safety is important.

Having several of the GFCI products in your department is just as easy as having many extension cords. GFCI’s become second nature once employees are trained to use them. No one wants to get electrocuted or injured. It is very easy to use them and highly effective in any environment!

TRC HD-Pro 24646-001 30 Amp Unit










Repeating: What is a GFCI

A ground-fault occurs when there is a break in the low-resistance grounding path from a tool or electrical system. The electrical current may then take an alternative path to the ground through the user, resulting in serious injuries or death. The ground-fault circuit interrupter, or GFCI, is a fast-acting circuit breaker designed to shut off electric power in the event of a ground-fault within as little as 1/40 of a second. It works by comparing the amount of current going to and returning from equipment along the circuit conductors. When the amount going differs from the amount returning by approximately 5 milliamperes, the GFCI interrupts the current.

The GFCI is rated to trip quickly enough to prevent an electrical incident. If it is properly installed and maintained, this will happen as soon as the faulty tool is plugged in. If the grounding conductor is not intact or of low-impedance, the GFCI may not trip until a person provides a path. In this case, the person will receive a shock, but the GFCI should trip so quickly that the shock will not be harmful.

The GFCI will not protect you from line contact hazards (i.e. a person holding two "hot" wires, a hot and a neutral wire in each hand, or contacting an overhead power line). However, it protects against the most common form of electrical shock hazard, the ground-fault. It also protects against fires, overheating, and destruction of wire insulation.

View Anderson-Bolds Safety Equipment HERE!

Anderson-Bolds
216-360-9800
www.anderson-bolds.com

GFCI...GFCI...GFCI...GFCI...GFCI...GFCI...GFCI...GFCI

Monday, March 30, 2020

RAYMAX from Watlow

RAYMAX® 1220 and 2030 Panel Heaters from Anderson-Bolds


for a quote please email to watlow@anderson-bolds.com
or use our WATLOW form HERE!

 Ideal For Many Process Heating Applications Requiring “Hot Face” Temperatures

The Raymax Panel heater product line from Watlow solves virtually an application requiring radiant heat from a contamination resistant surfaces to fast responding high temperature needs.

Watlow Raymax Radient Panel


Maximum face temperature up to 2000ºF

Typical applications are:
Thermoforming
Food warming
Paint and epoxy curing
Heat treating
High temperature Furnaces
Tempering and annealing processes




Raymax 1010
1000ºF Face Temperature

The Ryamax 1010 is the ideal for use in screen printing, food warming and other low heat applications. The Heater's "sealed face" keeps contaminates away from the heating element, and the metal surface can be easily wiped or brushed clean whenever needed.
Uniform full surface heat source
Convenient ready to use package
One inch thick backside insulation
Repeatable temperature sensing options
UL: component listing.

Heater width is from 4-20 inches
Heater Length is from 10 to 68 inches
voltage up to 480 vac
Watt Density is 10W/sq. inch
 Easy to install and capable of high surface temperatures,
the RAYMAX® 1220 and 2030 are ideal for many process
heating applications requiring “hot-face” temperatures
above 1000°F (540°C).
Each ceramic fiber heater is mounted in a 21⁄2 in. (64 mm)
deep sheet metal case providing thermal insulation. The case
includes post terminals for electrical connections and
provides a mounting system that can be used with virtually
any flat ceramic fiber unit. Watt density and temperature
capabilities can be tailored to meet a specific radiant
application for exposed sinuated embedded coil or foil
element configuration.

Performance Capabilities
• RAYMAX 2030 (uses sinuated or coil elements):temperatures up to 2000°F (1095°C); watt densitiesup to 30 W/in2 (4.7 W/cm2)
• RAYMAX 1220 (uses an etched foil element):temperatures up to 1200°F (650°C); watt densitiesup to 20 W/in2 (3 W/cm2)
• Maximum voltage up to 600V

Features and Benefits
Lightweight, low mass design
• Allows fast response to controllers
Self insulation with 21/2 in. (64 mm ) thick mounting case
• Provides high efficiency
Thermocouple mounting clamp
• Simplifies process system control
Aluminized steel case
• Handles temperatures up to 1100°F (595°C)
Special hot-face heating patterns
• Designed specifically for an application using an etched foil RAYMAX 1220

Specifications 
Weight: Less than 6.5 lbs/ft2 (31.75 kg/m2) 
Voltage and Wattage: Ratings, up to 600VAC are based on 
the ceramic fiber heater module mounted in the case. 
Terminals: Terminals are 1⁄4-20 threaded studs. Two terminals 
plus ground for single-phase, and three terminals plus ground 
for 3-phase are located on the center length line unless 
otherwise specified. Terminals can be positioned anywhere 
along lines A and B (see illustration below), but not closer 
than 2 in. (51 mm) to the case ends. 
Mounting Legs: Mounting legs are available either 
1 in. (25 mm) or 3 in. (76 mm) length. For made-to-order units, 
mounting legs can be supplied in any incremental length L 
from 1⁄2 in. (13 mm) to 3 in. (76 mm). Slots are not provided in 
legs less than 1 in. (25 mm) long. 

Application Hints 
A thermocouple mounting clamp is attached to one end of 
the case, with holes on both ends for alternate locations. 
The clamp can be used with 1⁄8 in. (3.2 mm) O.D. sheath 
thermocouples. The clamp is 3/16 in. (4.8 mm) high, but 
can be removed for flush mounting*. 
The maximum recommended surface temperature of the 
heater is based on the rating of the ceramic fiber heater 
module. This can vary from 2000°F (1095°C) at lower watt 
densities, to higher watt densities at reduced surface 
temperatures. Note: maximum wattages cannot be achieved 
at the maximum temperatures simultaneously. 
* 13⁄16 in. (4.8 mm) and 1⁄4 in. (6 mm) are available upon request. 

Options 
Several options are available with RAYMAX 1220 and 2030 
models. Contact your Watlow representative for more 
information. 
• Single-phase non-standard location power terminals 
• Terminal box 
• Zoning 
• Mounting studs and legs 
• 3-phase construction 
• Thermocouple mounting tubes 
• Alternate case materials 

RAYMAX 2030 PART NUMBERS
VP504A06T, VP504A12T, VP504A18T, VP504A24T, VP504A30T, VP504A36T
VP506A06T, VP506A12T, VP506A18T, VP506A24T, VP506A30T, VP506A36T
VP508A06T, VP508A12T, VP508A18T, VP508A24T, VP508A30T, VP508A36T
VP510A06T, VP510A12T, VP510A18T, VP510A24T, VP510A30T, VP510A36T
VP510A06T, VP510A12T, VP510A18T, VP510A24T, VP510A30T, VP510A36T
VP512A06T, VP512A12T, VP512A18T, VP512A24T, VP512A30T, VP512A36T
VP514A06T, VP514A12T, VP514A18T, VP514A24T, VP514A30T, VP514A36T
VP516A06T, VP516A12T, VP516A18T, VP516A24T, VP516A30T, VP516A36T


Anderson-Bolds
216-360-9800

Friday, June 19, 2015

Carlo Gavazzi Solid State Relays

Anderson-Bolds Sells Carlo Gavazzi Solid State Relays

Carlo Gavazzi offers a comprehensive range of solid state relays (SSR’s) featuring direct copper bonding technology for increased life and reliability. SSR’s are used extensively in the plastics, packaging, food processing, and HVAC industries - primarily for temperature control. They are the logical replacement for mercury contactors.

Other applications include lighting and pump switching. Furthermore, many of their solid state relays feature horsepower ratings making them suitable for controlling motorized dampers in HVAC control systems - where their long life and noise-free switching make them ideal replacements for mechanical contractors.

Carlo Gavazzi's solid state relays range includes single phase relays up to 125 amps and 3 phase relays up to 75 amps. They are available with both digital and analogue inputs (4-20 mA or 0-10 V) Furthermore, we also offer a complete range of SSR's with a built-in heatsink.



20 - 85 amp ratings, AC or DC inputs.  UP to 600 vac output or Operational Voltage and integrated heat sink.  CSA and UL listed.

Carlo Gavazzi Solid State Relay RGC1A23A15KKE is a 20 amp Zero Crossover SSR with built in Heat Sink and 20-275 VAC input. Operational or switching voltage is 24-240 AC.

Carlo Gavazzi Solid State Relay RGC1A23D20KKE is a 23 amp Zero Crossover SSR with built in Heat Sink and 3-32 vdc input. Operational or switching voltage is 24-240 AC.

Carlo Gavazzi Solid State Relay RGC1A23A30KKE is a 30 amp Zero Crossover SSR with built in Heat Sink and 20-275 VAC input. Operational or switching voltage is 24-240 AC.

Carlo Gavazzi Solid State Relay RGC1A60A60KGE is a 60 amp Zero Crossover SSR with built in Heat Sink and 20-275 VAC input. Operational or switching voltage is 42-600 AC.

Carlo Gavazzi Solid State Relay RGC1A60A62GGEP is a 65 amp Zero Crossover SSR with built in Heat Sink (W/FAN) and 20-275 VAC input. Operational or switching voltage is 42-600 AC.


Carlo Gavazzi RGC3 Series 3-Phase Solid State Relays
Carlo Gavazzi Three-Phase Solid State Relays with built in Heatsink, 20 to 75 amps, with either DC or AC input and up to 600 volts output. 

Carlo Gavazzi RGS Series Solid State Relays
Carlo Gavazzi Solid State Relays with built-in Heatsink and Varistor, 25 to 90 amps, single phase with either DC or AC input and up to 600 volts output. 

Please use our Carlo Gavazzi Parts Form to request a quote on any Solid State Relay or other Gavazzi part HERE.






Tuesday, May 1, 2012

Ohm's Law and Electric Heaters

Ohm's Law is the mathematical representation of electricity with regard to Voltage, Current, Resistance and Power (or Watts).  This is required information to know when sizing electric heaters, heating elements, electric water heaters and any high amperage appliances.

Anderson-Bolds Ohms Law Calculator (with 3 phase calculations too)

E = Voltage (Volts)
I  =  Current or Amps
R = Resistance (Ohms)
W = Watts (Power)

Formulas:

W = E x I 
W = I2 x R
W = E2 / R
I = W / E
I = (W / R)2
I = E ÷ R 
E = (W x R)2
E = W / I
E = I x R
R = E2 / W
R = W / I2
R = E ÷ I








What is Ohm's Law:
Ohm's Law is made from 3 mathematical equations that shows the relationship between electricvoltage, current and resistance.

What is voltage? An anology would be a huge water tank filled with thousands of gallons of water high on a hill.
The difference between the pressure of water in the tank and the water that comes out of a pipe connected at the bottom leading to a faucet is determined by the size of the pipe and the size of the outlet of the faucet. This difference of pressure between the two can be thought of as potential Voltage.

What is current? An analogy would be the amount of flow determined by the pressure (voltage) of the water thru the pipes leading to a faucet. The term current refers to the quantity, volume or intensity of electrical flow, as opposed to voltage, which refers to the force or "pressure" causing the current flow.

What is resistance? An analogy would be the size of the water pipes and the size of the faucet. The larger the pipe and the faucet (less resistance), the more water that comes out! The smaller the pipe and faucet, (more resistance), the less water that comes out! This can be thought of as resistance to the flow of the water current.
All three of these: voltage, current and resistance directly interact in Ohm's law.
Change any two of them and you effect the third.

Info: Ohm's Law was named after Bavarian mathematician and physicist Georg Ohm.
Ohm's Law can be stated as mathematical equations, all derived from the
same principle.
In the following equations,
V is voltage measured in 
volts (the size of the water tank),I is current measured in amperes (related to the pressure (Voltage) of water thru the pipes and faucet) and R is resistance measured in ohms as related to the size of the pipes and faucet:

V = I x R  (Voltage = Current multiplied by Resistance)
R = V / I  (Resistance = Voltage divided by Current)
 I = V / R  (Current = Voltage Divided by Resistance)


Ohm's Law defines the relationships between (P) power, (E) voltage, (I) current, and (R) resistance. One ohm is the resistance value through which one volt will maintain a current of one ampere.

( I ) Current is what flows on a wire or conductor like water flowing down a river. Current flows from negative to positive on the surface of a conductor. Current is measured in (A) amperes or amps.

( E ) Voltage is the difference in electrical potential between two points in a circuit. It's the push or pressure behind current flow through a circuit, and is measured in (V) volts.

( R ) Resistance determines how much current will flow through a component. Resistors are used to control voltage and current levels. A very high resistance allows a small amount of current to flow. A very low resistance allows a large amount of current to flow. Resistance is measured in  ohms.

( P ) Power is the amount of current times the voltage level at a given point measured in wattage or watts.




Thursday, July 8, 2010

TRC High Power GFCI's ~ Ground Fault Circuit Interrupter


Anderson-Bolds and TRC

Avoiding electrical accidents and equipment damage are keys to reducing liability and increasing productivity. Minimum ground fault protection can be incorporated into the main power disconnect device and could be considered adequate for the entire system. However, in such a design, any downstream ground fault could trip the main protective device resulting in a complete substation power outage. The NEC’s purpose, in its own words, is “the practical safeguarding of persons and property…but not necessarily efficient, convenient, or …for good service…” (Article 90.1A, B). In other words, system reliability is left to common sense and good engineering design practices. For this reason ground fault protection of the circuit may be highly desirable and recommended for reliable and continuous operation.
TRC engineers designed the HD-PRO models specifically for high current, rugged environments and these models are field-proven in all kinds of tough applications. The entire HD-PRO family (120V/30A to 600V/80A) is designed to trip within 25 milliseconds after ground fault detection at an adjustable selected trip level of 6, 10 or 30 mA.
ARC WELDING APPLICATIONS
Arc welding is described as using a welding power supply to create an electric arc between an electrode and the base material to melt the metals at the welding point. The process of arc welding is widely used because of its low capital and running costs.
Arc welding can use either direct (DC) or alternating (AC) current as the power source to create the arc. The arc process needs a large amount of current, up to 500A, but at a relatively low arc voltage; 10 to 40V, with a typical high voltage main power supply, and 230 to 400V, that must be reduced. In all manual arc welding operations the main risk is electric shock, most likely from contact with bare live parts of the welding circuit. Appropriate protective clothing and ground fault protection is the first line of defense in the event of an electrical hazard from stray currents. Bad equipment can be replaced in a short time; however, fire and serious injury or death caused by a ground fault could shut down a facility for several days or weeks.
How to avoid electrical shock: Always use a local ground fault circuit interrupter (GFCI) with welding equipment and, prior to use, always test the GFCI for proper operation. Use well-insulated electrode holders and cables. Make sure welding cables are dry and free of grease and oil. Keep welding cables away from power supply cables. Wear dry hole-free gloves, clothing should also be dry. Insulate welder from the ground by using dry insulation such as rubber mat or dry wood. Ground frames of welding units. Never change electrodes with bare hands or wet gloves.
Fortunately, ground fault protection is easy to apply if you understand the basics. Simply put, a ground fault occurs when electrical current finds a bridge to ground via worn insulations, conductive dusts, water or other “soft grounds”, instead of the normal path back to its source. More than 80% of short circuits in equipment are ground faults, and 90% of these events are due to insulation deterioration on wires and cables. In cases where workers accidentally bridge power and ground, current in the mA range can send their heart into ventricular fibrillation.
A GFCI functions by measuring the outgoing amperage to a piece of equipment and comparing it against the return amperage. If a difference (leak) of >5 milliamps occurs (or set higher for certain equipment), the GFCI stops the flow of electricity to protect equipment and workers from potential electrocution.
Avoiding electrical accidents and equipment damage are keys to reducing liability and increasing productivity. Minimum ground fault protection can be incorporated into the main power disconnect device and could be considered adequate for the entire system. In such a design, however, any downstream ground fault could trip the main protective device resulting in a complete substation power outage. The NEC’s purpose, in its own words, is “the practical safeguarding of persons and property…but not necessarily efficient, convenient, or …for good service…” (Article 90.1A, B). In other words, system reliability is left to common sense and good engineering design practices. For this reason ground fault protection of the circuit may be highly desirable and recommended for reliable and continuous operation.
Also, in order to comply with OSHA Regulations’ recent change, “construction-like” work using temporary power arrangements which takes place in the nation’s manufacturing plants, refineries, processing facilities and other locations, must be done with workers using GFCI protected equipment.



Industrial pressure washers are powerful tools used for washing buildings, bricks, floors, storefronts, parking lots, dumpsters,
bus fleets, machinery, farm equipment, engines and more. From industrial power plants to disaster clean-up you will find all
types of high end power pressure washers being used for many industrial applications. These machines are sophisticated
and built with more durable pumps and components then the residential units. They are also used in extreme environmental
conditions requiring more power; thereby posing a greater safety risk to individuals if not used properly.
A “Ground Fault” is a dangerous electrical condition where current flows unintentionally
between a live conductor and ground. A severe or fatal electric shock can occur when a user
touches the pressure washer if the machine is ungrounded. This could happen if the power
cord to extension cord connections become wet or a fault exists within the pressure washer’s
sophisticated electrical system. GFCI’s prevent possible electrocution and equipment damage
due to electrical malfunction. Once the GFCI trips, the power is interrupted, stopping the
pressure washer power and making it electrically safe for people and preventing costly
equipment damage.
The 1987 edition of the National Electrical Code requires that pressure washers be protected by ground fault interrupters to
prevent electrocutions. Also, the Underwriters Laboratories revised UL1776 requires the use of GFCI’s for all UL listed
pressure washers effective as of May 6, 2000.
Avoiding electrical accidents and equipment damage are keys to reducing liability and increasing productivity. Guidelines for
electrical safety are:
Always use and test the ground fault circuit interrupter (circuit breaker or outlet) before using a pressure washer.
Always plug a properly grounded pressure washer into a properly grounded receptacle.
Never remove the grounding prong from the pressure washer’s power cord plug or from the extension cord.
Always have a qualified electrician check the pressure washer for electrical problems after it has tripped a circuit
breaker.


Moving large heavy loads is crucial to today's manufacturing and construction industries. Hoists are one of the top

productivity-enhancing tools found almost anywhere goods are regularly moved, worked on and/or mounted into an
assembly. Some hoists use chains, ropes, or cable, but regardless, most use A/C motors. A burnt out motor can be replaced
in a short time, but fire or serious injury or death caused by a ground fault could shut down a facility for several days or

weeks. Fortunately, ground fault protection is easy to apply if you understand the basics.
A ground fault occurs when electrical current finds a bridge to ground via worn insulations,
conductive dusts, water or other “soft grounds” instead of the normal path back to its source.
More than 80% of short circuits in equipment are ground faults, and 90% of these events are
due to insulation deterioration on wires and cables. In cases where workers accidentally bridge
power and ground, current in the mA range can send their hearts into ventricular fibrillation.
A GFCI (Ground Fault Circuit Interrupter) functions by measuring the outgoing amperage to a
piece of equipment and comparing it against the return amperage. If a difference (leak) of > 5
milliamps occurs (or set higher for certain equipment), the GFCI stops the flow of electricity to
protect equipment and workers from potential electrocution.
Avoiding electrical accidents and equipment damage are keys to reducing liability and increasing productivity. Minimum

ground fault protection can be incorporated into the main power disconnect device and could be considered adequate for the
entire system. In such a design, however, any downstream ground fault could trip the main protective device resulting in a

complete substation power outage. The NEC’s purpose, in its own words, is “the practical safeguarding of persons and

property…but not necessarily efficient, convenient, or …for good service…” (Article 90.1A, B). In other words, system
reliability is left to common sense and good engineering design practices. For this reason ground fault protection of the
circuit may be highly desirable and recommended for reliable and continuous operation.

Guidelines for electrical safety are:
Know where the GFCI is located in the hoist power system. If there is not a GFCI installed, have one installed local

to the hoist to confirm you have protection.

Always test the GFCI before using the hoist.
Always have a qualified electrician check the hoist for electrical problems after it has tripped a GFCI.

CONVEYORS

Conveyors are commonly found in factories, industrial facilities, warehouses, distribution centers and in a large number of
manufacturing workplaces. A top productivity-enhancing tool, conveyor systems are used in almost every manufacturing
environment where goods are regularly moved from one location to another. Because of this, conveyor injuries in the U.S.
may cost employers millions of dollars each year; however, with the right processes, design and safety considerations,
employers can reduce cost and liability.
Conveyors are often driven by variable speed electric motors integrated (hardwired) into
complex power systems. As with any electronic equipment they are subject to failure for many
conveyor location to isolate equipment protection and to test the GFCI prior to equipment use.
possible reasons. To protect people who use electrically-powered conveyors, each conveyor
must be equipped with a “Ground Fault Circuit Interrupter” (GFCI) preferably localized at the
GFCI’s prevent possible electrocution and equipment damage due to electrical malfunction.
Once the GFCI trips, the power is interrupted, stopping the conveyor system and making it
electrically safe for people and preventing costly equipment damage.
Ground fault protection is an important consideration for virtually all electrical equipment. A Ground Fault is a dangerous
electrical condition where current flows unintentionally between a live conductor and ground. This could happen if the power
unit or power cables become damaged, wet or a fault exists within the conveyor’ssophisticated electrical system. Avoiding
electrical accidents and equipment damage are keys to reducing liability and increasing productivity.
Guidelines for electrical safety are:
Know where the ground fault circuit interrupter is located in the conveyor power system. If there is not a GFCI
installed, report this to your safety officer.
Always test the ground fault circuit interrupter before using the conveyor.
Always have a qualified electrician check the conveyor for electrical problems after it has tripped a groundfault
circuit interrupter.




TRC engineers designed the HD-PRO models specifically for high current, rugged environments and these models are field-proven in all kinds of tough applications. The entire HD-PRO family (120V/30A to 600V/80A) is designed to trip within 25 milliseconds after ground fault detection at an adjustable selected trip level of 6, 10 or 30 mA.
Before the development of the HD-PRO Series, facilities with high current – high voltage equipment or three phase systems employed expensive ground fault breakers at the source of the branch circuit, or went without ground fault protection, leaving personnel and equipment unprotected.
Circuit breakers can withstand high current levels but have short mechanical lives and were not designed for switching duty. Localized ground faults, with circuit breakers, either shut down the whole branch circuit or were overloaded because the available devices were not portable and were often too costly.
The HD-PRO Series utilizes contactors that are fully rated for motor switching demands. In addition to being far less expensive than three phase breakers, the HD-PRO models protect expensive high current – high voltage equipment at the point of use while offering substantial shock protection for personnel.
TRC is an internationally recognized leader in electrical safety products
that protect equipment, prevent electrical fires and protect against electrocution and serious injury from electrical shock.