These are the new Southwire TRC 24736-001 and 24994-001 100 amp 6-10-30 Trip Level GFCI and ELCI Units.
Anderson-Bolds is your source for Commercial safety products including GFCIs and ELCIs.
GFCIs and ELCIs are used for personnel and equipment protection.
TRC has engineered a new option for the HD-PROTM series called
6.10.30TM.
Configured for both in-line and bulk head mount. This unique new design allows the user to select and lock in the most sensitive trip level at which a specific type of equipment can be operated without nuisance tripping. Adjustable settings
include trip levels for 6mA, 10mA and 30mA. Trip level flexibility to meet your needs in one single device - HD-PROTM with 6.10.30TM. 6.10.30TM key enables trip level selection and locking at a trip level with key removal.
The GFCIs protect Motors, Pumps, Pressure Washers, Conveyors, Welders and lifts.
Go To GFCI/ELCI Store Page HERE. or call 216-360-9800
Specifications:
Voltage: 480 or 600 volts AC and three phase
AMPS: 100
Cord Gauge: 2/4 AWG
Trip Levels: 6mA, 10mA, 30mA - chosen by Key Switch
GFCI Response Time: 25mS
Frequency: 50/60 Hz
Endurance: 3,000 operations minimum
Overload Current: SIX times rated current
Temperature Range: -20C to +40C
Power n Indicator: Light
Drop Out Voltage: About 60% rated voltage
Reset Type: Auto
Connection: Flying Leads
Enclosure: NEMA 4 Polymer
216-360-9800
www.anderson-bolds.com
Configured for both in-line and bulk head mount. This unique new design allows the user to select and lock in the most sensitive trip level at which a specific type of equipment can be operated without nuisance tripping. Adjustable settings
include trip levels for 6mA, 10mA and 30mA. Trip level flexibility to meet your needs in one single device - HD-PROTM with 6.10.30TM. 6.10.30TM key enables trip level selection and locking at a trip level with key removal.
The GFCIs protect Motors, Pumps, Pressure Washers, Conveyors, Welders and lifts.
Go To GFCI/ELCI Store Page HERE. or call 216-360-9800
TRC 24736-001 and TRC 24994-001 100 amp GFCI/ELCI |
Specifications:
Voltage: 480 or 600 volts AC and three phase
AMPS: 100
Cord Gauge: 2/4 AWG
Trip Levels: 6mA, 10mA, 30mA - chosen by Key Switch
GFCI Response Time: 25mS
Frequency: 50/60 Hz
Endurance: 3,000 operations minimum
Overload Current: SIX times rated current
Temperature Range: -20C to +40C
Power n Indicator: Light
Drop Out Voltage: About 60% rated voltage
Reset Type: Auto
Connection: Flying Leads
Enclosure: NEMA 4 Polymer
216-360-9800
www.anderson-bolds.com