Industrial pressure washers are powerful tools used for washing buildings, bricks, floors, storefronts, parking lots, dumpsters,
bus fleets, machinery, farm equipment, engines and more. From industrial power plants to disaster clean-up you will find all
types of high end power pressure washers being used for many industrial applications. These machines are sophisticated
and built with more durable pumps and components then the residential units. They are also used in extreme environmental
conditions requiring more power; thereby posing a greater safety risk to individuals if not used properly.
A “Ground Fault” is a dangerous electrical condition where current flows unintentionally
between a live conductor and ground. A severe or fatal electric shock can occur when a user
touches the pressure washer if the machine is ungrounded. This could happen if the power
cord to extension cord connections become wet or a fault exists within the pressure washer’s
sophisticated electrical system. GFCI’s prevent possible electrocution and equipment damage
due to electrical malfunction. Once the GFCI trips, the power is interrupted, stopping the
pressure washer power and making it electrically safe for people and preventing costly
equipment damage.
The 1987 edition of the National Electrical Code requires that pressure washers be protected by ground fault interrupters to
prevent electrocutions. Also, the Underwriters Laboratories revised UL1776 requires the use of GFCI’s for all UL listed
pressure washers effective as of May 6, 2000.
Avoiding electrical accidents and equipment damage are keys to reducing liability and increasing productivity. Guidelines for
electrical safety are:
Always use and test the ground fault circuit interrupter (circuit breaker or outlet) before using a pressure washer.
Always plug a properly grounded pressure washer into a properly grounded receptacle.
Never remove the grounding prong from the pressure washer’s power cord plug or from the extension cord.
Always have a qualified electrician check the pressure washer for electrical problems after it has tripped a circuit
breaker.
Moving large heavy loads is crucial to today's manufacturing and construction industries. Hoists are one of the top
productivity-enhancing tools found almost anywhere goods are regularly moved, worked on and/or mounted into an
assembly. Some hoists use chains, ropes, or cable, but regardless, most use A/C motors. A burnt out motor can be replaced
in a short time, but fire or serious injury or death caused by a ground fault could shut down a facility for several days or
weeks. Fortunately, ground fault protection is easy to apply if you understand the basics.
A ground fault occurs when electrical current finds a bridge to ground via worn insulations,
conductive dusts, water or other “soft grounds” instead of the normal path back to its source.
More than 80% of short circuits in equipment are ground faults, and 90% of these events are
due to insulation deterioration on wires and cables. In cases where workers accidentally bridge
power and ground, current in the mA range can send their hearts into ventricular fibrillation.
A GFCI (Ground Fault Circuit Interrupter) functions by measuring the outgoing amperage to a
piece of equipment and comparing it against the return amperage. If a difference (leak) of > 5
milliamps occurs (or set higher for certain equipment), the GFCI stops the flow of electricity to
protect equipment and workers from potential electrocution.
Avoiding electrical accidents and equipment damage are keys to reducing liability and increasing productivity. Minimum
ground fault protection can be incorporated into the main power disconnect device and could be considered adequate for the
entire system. In such a design, however, any downstream ground fault could trip the main protective device resulting in a
complete substation power outage. The NEC’s purpose, in its own words, is “the practical safeguarding of persons and
property…but not necessarily efficient, convenient, or …for good service…” (Article 90.1A, B). In other words, system
reliability is left to common sense and good engineering design practices. For this reason ground fault protection of the
circuit may be highly desirable and recommended for reliable and continuous operation.
Guidelines for electrical safety are:
Know where the GFCI is located in the hoist power system. If there is not a GFCI installed, have one installed local
to the hoist to confirm you have protection.
Always test the GFCI before using the hoist.
Always have a qualified electrician check the hoist for electrical problems after it has tripped a GFCI.
CONVEYORS
Conveyors are commonly found in factories, industrial facilities, warehouses, distribution centers and in a large number of
manufacturing workplaces. A top productivity-enhancing tool, conveyor systems are used in almost every manufacturing
environment where goods are regularly moved from one location to another. Because of this, conveyor injuries in the U.S.
may cost employers millions of dollars each year; however, with the right processes, design and safety considerations,
employers can reduce cost and liability.
Conveyors are often driven by variable speed electric motors integrated (hardwired) into
complex power systems. As with any electronic equipment they are subject to failure for many