GFCI's and OSHA Violations

 GFCI Products to Remedy OSHA Violations

TRC GFCI 14650-006







An OSHA violation is a serious matter. Many of them can result in injury or death. Some violations are obvious and easy to spot while others require training and a comprehensive understanding of the requirements in order to detect them.

For example, improper Lockout/Tagout of energized equipment or machine guarding, although not simple, might be easier to notice and correct than electrical code violations that require a detailed understanding of the written rules and are likely to be unnoticed by many at the site.

Although most of the people understand basic electricity (e.g., not sticking metal objects into outlets,  it is still perceived as a very complicated topic.

However, not all electrical violations are complicated. Some basic OSHA-mandated safety requirements are very easy to spot and correct if one knows what to look for. Among the top ten most frequently cited standards violations for 2014-2015, electrical-related standards violations are number 8 and 10 on the list.


Top 10 Most Frequently Cited Standards violations for Fiscal 2015 (Oct. 1, 2014, to Sept. 30, 2015)

1.       Fall Protection (1926.501)

2.       Hazard Communication (1910.1200)

3.       Scaffolding (1926.451)

4.       Respiratory Protection (1910.134)

5.       Lockout/Tag Out (1910.147)

6.       Powered Industrial Trucks (1910.178)

7.       Ladders (1926.1053)

8.       Electrical – Wiring Methods (1910.305)

9.       Machine Guarding (1910.212)

10.     Electrical – General Requirements (1910.303)


Anderson-Bolds can help with Fall Protection, Lockout/Tag Out,

 Machine Guarding and Electrical (GFCIs).


30 Amp Inline GFCI with locking plugs





Now we are unlikely to be able to educate everyone on everything, but what we can achieve is to give some basic ideas on how these violations can be decreased and potentially save lives. If, as a result of this article, we save one life we could not be happier and it is sad to see people getting injured for something that is so easy to avoid.

So what exactly is so easy to fix? Use a work site Ground Fault Circuit Interrupter or GFCI for short! If you have employees working in a location that has temporary power, it is highly recommended to use a GFCI on every electrical circuit or service, even if there are no OSHA regulations requiring it.

For example , with the use of tools like wet vacs, power washers, wet saws or drills used to mix cement, it is a good practice to have GFCI’s installed to protect employees who work with this equipment. Per OSHA, all construction sites and construction site-like activities that use extension cords or certain equipment have to be GFCI protected2. As a rule of thumb, if you have power equipment outdoors, or near moisture/water you need to use GFCI-protected devices. OSHA estimates that since the GFCI requirement was implemented in 1970, the rule has saved more than 650 lives. That is one person a month since 1970!  

What is a GFCI? (Ground Fault Circuit Interrupter)

GFCI is an electrical device that measures the difference between output and input load current, opening whenever a difference is detected that could pose a safety hazard. If there is a current difference of more than 6 milliamps (mA), the GFCI unit will disconnect power to the load. Don’t be fooled into using a standard circuit breaker. Circuit breakers are designed to protect equipment not people!

GFCI’s come in a variety of forms and shapes, but for MRO or construction industries, the two most common options are right angle plug adapters or corded GFCIs that have a power cord and multiple output sockets. Each type might come with various additional features, especially the corded models. Corded models can offer different cord lengths from 2 ft up to 100 ft long, and also illuminated outlets and various socket configurations.

Something to remember is that socket multipliers and surge protectors are not the same as a Ground Fault Circuit Interrupter or GFCI for short. A GFCI is the only device designed specifically to protect people, whereas everything else is designed to protect equipment from damage due to high voltage transients. This is important to remember in order to choose the appropriate device for its intended application. If you have a device and you want to protect equipment from damaging power transients, then use a surge protector. However, if your primary concern is to protect employees, a GFCI is the only product capable of doing it.

A properly designed and manufactured GFCI unit will continue to provide protection when hazardous wiring conditions present. For example mis-wiring the neutral wire and a hot wire at the circuit breaker or outlet will not impede the GFCI’s ability to offer protection.

There are certain circumstances when a GFCI might not prevent a shock, such as when a person touches  both electric wires at the same time, offering a path from one wire in through one hand, through the body, and out on the other hand to the other electric wire. In this situation the GFCI will not sense a current imbalance and will not trip. This is a very important point to consider when training personnel working on equipment with GFCIs.

GFCI’s are intended to trip if current is passing through a path to ground; this could be from a tool or piece of equipment through the user. The GFCI is intended to trip quickly, so the user is not harmed.

It should be noted that a shock can be felt even with a GFCI, but the GFCI will trip quickly enough to avoid an injury.

When looking for a GFCI something to keep in mind is the design of the product. Although there are a lot of products available on the market, the most reliable products carry a UL approval. UL is the leading safety organization with best test and follow up practices. This ensures products are produced with safety critical aspects continually tested and validated in the factory. You might find some products that are few dollars cheaper, but do not carry UL approval and they may perform just as well. The key here is “may”. Products that have UL approval have undergone the most rigorous testing and follow up inspection, and so it should be the “product of choice” when personnel safety is important.

Having several of the GFCI products in your department is just as easy as having many extension cords. GFCI’s become second nature once employees are trained to use them. No one wants to get electrocuted or injured. It is very easy to use them and highly effective in any environment!

TRC HD-Pro 24646-001 30 Amp Unit










Repeating: What is a GFCI

A ground-fault occurs when there is a break in the low-resistance grounding path from a tool or electrical system. The electrical current may then take an alternative path to the ground through the user, resulting in serious injuries or death. The ground-fault circuit interrupter, or GFCI, is a fast-acting circuit breaker designed to shut off electric power in the event of a ground-fault within as little as 1/40 of a second. It works by comparing the amount of current going to and returning from equipment along the circuit conductors. When the amount going differs from the amount returning by approximately 5 milliamperes, the GFCI interrupts the current.

The GFCI is rated to trip quickly enough to prevent an electrical incident. If it is properly installed and maintained, this will happen as soon as the faulty tool is plugged in. If the grounding conductor is not intact or of low-impedance, the GFCI may not trip until a person provides a path. In this case, the person will receive a shock, but the GFCI should trip so quickly that the shock will not be harmful.

The GFCI will not protect you from line contact hazards (i.e. a person holding two "hot" wires, a hot and a neutral wire in each hand, or contacting an overhead power line). However, it protects against the most common form of electrical shock hazard, the ground-fault. It also protects against fires, overheating, and destruction of wire insulation.

View Anderson-Bolds Safety Equipment HERE!

Anderson-Bolds
216-360-9800
www.anderson-bolds.com

GFCI...GFCI...GFCI...GFCI...GFCI...GFCI...GFCI...GFCI

Sunday, March 31, 2019

Maximize Electric Heater Performance

Ten Tips to Maximize Heater Performance


Electric Heating elements are very durable and can last a png time with some preventative care for the elements. In the industrial world some heaters are put ito abusive environments so using some of these tis could add life to your electrical heating elements and heaters. 

Contact Anderson-Bolds HERE!


Watlow Firebar Elements

















Many plant engineers do not give much thought to the heaters operating within their processes and applications - unless those heaters fail, require significant maintenance or cause other problems. Unfortunately, heaters play an integral role in many applications. Therefore, heater problems can easily snowball and lead to much larger headaches.

Following a few simple guidelines will not only reduce the likelihood of heater-related issues, but can actually have a significant positive impact on the efficiency of systems and reduce maintenance requirements and costs. Below are 10 ways to maximize a heater's service life and performance.

Tip 1: Guard against heater contamination

Contamination is the most frequent cause of heater failure (see images). As heaters expand and contract during cycling, they often draw in organic or conductive materials. This can lead to an arcing failure between individual heater windings or between heater windings and the electrically grounded outer heater sheath. When allowed to collect at the lead end of a heater, contaminants can also cause electrical shorts between power pins or terminals. Therefore, it is important to keep lubricants, oils, low-temperature tapes or processing materials out of contact with the lead end of the heater. Employing seals will help.

Tip 2: Protect leads and terminations from high temperatures and excessive movement

Standard fiberglass-insulated lead wire may be used in applications with ambient temperatures up to approximately 260°C (500°F). If a lead is exposed to higher temperatures, high-temperature lead wire or ceramic bead insulation should be used. An unheated section of the heater, extending away from the heated region of the system, enables the leads to run at a beneficially cooler temperature.
When heaters are mounted in moving machinery, it is essential to anchor the leads to prevent them from being damaged. A lead protection option should be specified and used for optimum protection against lead damage.

Tip 3: Heater selection and sizing are important

A heater's wattage should be matched as closely as possible to the application's actual load requirements to limit ON/OFF cycling (see tip 6). For fitted-part applications, specify the hole or an alternative application feature size to ensure an optimal fit between the heater and application feature. A tight fit minimizes air gaps and reduces the instances of hot spotting.

Tip 4: Ground the equipment

It is common sense and safe practice to electrically ground all equipment on which the heater is used. Grounding equipment helps protects plant and personnel in the event of an electrical failure in the heating system.

Tip 5: Regulating voltage ensures the rated heater voltage matches voltage supply

It is essential to ensure a heater's rated voltage matches the available voltage supply because wattage increases (or decreases) at the square of the change in voltage applied to a heater. For example, if a heater is rated for 120V/1000W and is connected to a 240V supply, it will generate four times the rated wattage output or 4000W. This will cause a heater to fail relatively quickly and can also cause significant damage the attached equipment.

Tip 6: Prevent excessive heater cycling

Excessive temperature cycling is very detrimental to the life of a heater. The most detrimental is the cycle rate that allows full expansion and contraction of the heater resistance wire at a high rate (30 to 60 seconds' power ON and power OFF). This causes severe stress and oxidation of the resistance wires inside a heater. A bad temperature cycle is typically found when thermostats are used. Thermostats respond slowly to temperature changes and have large switch ON/OFF temperature differentials. An improvement, but a somewhat more expensive solution, is to use ON/OFF or PID controllers with mechanical relays. It is crucial to not switch the frequency or cycle time too rapidly (somewhere between 3 to 10 seconds), because the relay contacts can wear out quickly.
The most effective way to minimize heater element temperature cycling, and the most expensive solution, is to use solid state relays (SSRs) and SCR power controllers coupled to PID temperature controllers. This combination provides the best performance for both your thermal system as well as for the heater itself. Solid state switching devices cycle power to the heater very rapidly (from one second with a SSR, down to milliseconds with phase-angle fired SCRs). This fast-power cycling dramatically reduces heater element wire temperature excursions and substantially extends heater life.

Tip 7: Ensure that the sheath material and watt density ratings are compatible with the material being heated

This is absolutely critical to ensure long heater life and healthy processing equipment. When heating solids, such as metals, the operating temperature and heater-to-part fit drive sheath material and watt density choices. Carbon steels, aluminum, silicone rubber sheath materials are fine for lower temperatures (a few hundred degrees). However, as temperatures increase beyond this point, sheath material choices become limited to galvanized or stainless steels and other higher temperature metal alloys. As temperature also increases, the watt density must decrease accordingly to prevent internal resistance wires from oxidizing quickly and failing prematurely. A good heater-to-part fit ensures proper heat transfer and does not force the resistance wires to overheat.

When heating gases, the operating temperature and flow rates dictate what sheath material and watt density can be used. For example, you can run higher watt densities when heating hydrogen versus nitrogen, but hydrogen requires Alloy 800 sheaths, whereas 304 Stainless Steel will work for many nitrogen applications.
Increasing flow and turbulence across the heater elements means better heat transfer, which raises watt density values. For liquid heating, the prime driver for materials and watt density selection is the fluid material and flow rate. Water can easily handle 42.52 to 70.87W/cm2 (60 to 100W/in2) using a copper sheath, whereas a 50/50-water/glycol mix can only handle 21.26 W/cm2 (30 W/in2) and must use a steel sheath.

Tip 8: Mount immersion tank heaters horizontally near the tank bottom

Heaters should be placed horizontally and near tank bottoms to maximize convective circulation. Vertical mounting is only advisable when limitations, such as space restrictions, prohibit horizontal placement. Regardless of whether a heater is mounted horizontally or vertically, it is essential to place it high enough to avoid any sludge and debris buildup in the bottom of the tank. Likewise, for both mounting methods, the entire heated length of the heater must be immersed at all times - one reason vertical mounting is rarely recommended. It is also important to avoid placing heaters in restricted spaces that limit convective flow and/or where free boiling or steam traps can occur.

Tip 9: Prevent build-up and sludge on the heater elements

Scale, coking and sludge build-up on heater sheaths must be minimized. Any accumulation should be periodically removed or at least minimized, to avoid inhibiting heat transfer to the liquid. Periodic cleaning prevents heater elements being forced to operate at higher temperatures, which can lead to early heater failure. Extreme care should also be taken to avoid getting silicone lubricant on the heated section of a heater. Silicone will prevent the "wetting" of the sheath by the liquid, act as an insulator, and possibly cause the heater to fail.

Tip 10: Ensure proper, tight temperature control and safety limit protection

Matching the appropriate temperature control system to the heater is imperative to strong heater performance and life. Each process application should, at the very least, include a process temperature sensor (to sense the material being heated) and a limit sensor (to sense the heater sheath temperature). The process sensor should be directly immersed into the material to be heated, or snugly inserted into a thermowell inside the fluid itself. For safety reasons, two separate control systems should be used - one for process temperature control and one for high limit control. PID type process temperature controllers offer more stable control and faster response than ON/OFF switching controls or thermostats. The trade off is that PID control is often more expensive than ON/OFF types and not always necessary for applications that do not require highly accurate temperature control.












Anderson-Bolds
216-360-9800

Watlow Heaters and Controls - Process Technology - Chromalox - Process Heat

Tuesday, May 1, 2012

Ohm's Law and Electric Heaters

Ohm's Law is the mathematical representation of electricity with regard to Voltage, Current, Resistance and Power (or Watts).  This is required information to know when sizing electric heaters, heating elements, electric water heaters and any high amperage appliances.

Anderson-Bolds Ohms Law Calculator (with 3 phase calculations too)

E = Voltage (Volts)
I  =  Current or Amps
R = Resistance (Ohms)
W = Watts (Power)

Formulas:

W = E x I 
W = I2 x R
W = E2 / R
I = W / E
I = (W / R)2
I = E ÷ R 
E = (W x R)2
E = W / I
E = I x R
R = E2 / W
R = W / I2
R = E ÷ I








What is Ohm's Law:
Ohm's Law is made from 3 mathematical equations that shows the relationship between electricvoltage, current and resistance.

What is voltage? An anology would be a huge water tank filled with thousands of gallons of water high on a hill.
The difference between the pressure of water in the tank and the water that comes out of a pipe connected at the bottom leading to a faucet is determined by the size of the pipe and the size of the outlet of the faucet. This difference of pressure between the two can be thought of as potential Voltage.

What is current? An analogy would be the amount of flow determined by the pressure (voltage) of the water thru the pipes leading to a faucet. The term current refers to the quantity, volume or intensity of electrical flow, as opposed to voltage, which refers to the force or "pressure" causing the current flow.

What is resistance? An analogy would be the size of the water pipes and the size of the faucet. The larger the pipe and the faucet (less resistance), the more water that comes out! The smaller the pipe and faucet, (more resistance), the less water that comes out! This can be thought of as resistance to the flow of the water current.
All three of these: voltage, current and resistance directly interact in Ohm's law.
Change any two of them and you effect the third.

Info: Ohm's Law was named after Bavarian mathematician and physicist Georg Ohm.
Ohm's Law can be stated as mathematical equations, all derived from the
same principle.
In the following equations,
V is voltage measured in 
volts (the size of the water tank),I is current measured in amperes (related to the pressure (Voltage) of water thru the pipes and faucet) and R is resistance measured in ohms as related to the size of the pipes and faucet:

V = I x R  (Voltage = Current multiplied by Resistance)
R = V / I  (Resistance = Voltage divided by Current)
 I = V / R  (Current = Voltage Divided by Resistance)


Ohm's Law defines the relationships between (P) power, (E) voltage, (I) current, and (R) resistance. One ohm is the resistance value through which one volt will maintain a current of one ampere.

( I ) Current is what flows on a wire or conductor like water flowing down a river. Current flows from negative to positive on the surface of a conductor. Current is measured in (A) amperes or amps.

( E ) Voltage is the difference in electrical potential between two points in a circuit. It's the push or pressure behind current flow through a circuit, and is measured in (V) volts.

( R ) Resistance determines how much current will flow through a component. Resistors are used to control voltage and current levels. A very high resistance allows a small amount of current to flow. A very low resistance allows a large amount of current to flow. Resistance is measured in  ohms.

( P ) Power is the amount of current times the voltage level at a given point measured in wattage or watts.




Thursday, May 5, 2011

Watlow Electric Heaters


Watlow Electric Heaters

Cartridge / Insertion Heaters

Watlow’s cartridge heaters and insertion heaters can be inserted into holes, used as immersion heaters placed directly in liquid or in protective wells, or can be mounted in pipes or vessels.Watlow designed and manufactured the first swaged cartridge heater and revolutionized the heating element industry.
With premium materials and tight manufacturing controls, Watlow's cartridge heaters (insertion heaters) provide superior heat transfer, uniform temperatures, resistance to oxidation and corrosion and long life even at high temperatures.



Tubular Heaters


Tubular heaters are used for immersion and air heating applications. They can be clamped to objects such as vessels and tanks, fitted into milled groove platens, immersed directly into a liquid being heated or even mounted in ducts for heating air and gas. Heaters are available as single- and double-ended, and can be formed to complex geometries. Single- and double-ended tubular heaters lend themselves to virtually the entire range of immersion and air heating applications. They have a variety of mounting and termination options that make them ideal for industrial applications. Watlow® tubular heaters are UL® and CSA component recognized up to 240V.

Flexible Heaters

Flexible heaters are commonly used to heat irregular surfaces, shapes and pipes. These heaters can be bonded or fastened to parts and are often used for freeze protection. Flexible heaters from Watlow are thin, bendable and shaped to fit almost any equipment. Heat can be applied to the most complex shapes, geometries, curves and pipes conceivable without sacrificing efficiency or dependability.


Immersion Heaters

These heaters can be immersed directly in the liquid being heated or put in protective wells. Multiple style mounting adaptors are available. Watlow's immersion heaters are designed primarily for direct immersion in liquids such as water, oils, solvents and process solutions, molten materials as well as air and gases. By generating all the heat within the liquid or process, these heaters are virtually 100 percent energy efficient. These versatile heaters can also be formed and shaped into various geometries for radiant heating and contact surface heating applications. UL® and CSA component recognized elements are available.

Circulation Heaters


Watlow’s diverse array of circulation heaters range from quartz heaters for aggressive chemicals to large pressure vessel heaters with capabilities up to 3000psi. These heaters can be used for liquids or gases in various applications. Watlow's circulation heaters are compact heating systems for fluids and gases. These heaters are ideal for applications such as purified and inert gases, supercritical fluids and liquids like de-ionized water for use in semiconductor and electronics industries as well as for general liquid and gas heating applications.


Fluid Delivery Heaters


Watlow fluid delivery heaters provide overall reliable, responsive heating for fluid delivery systems in medical, analytical, water purification and general process applications. Watlow fluid delivery heaters offer precise, repeatable heating, control improving product life. Watlow® innovative fluid delivery heaters produce consistent results by reducing temperature and viscosity variations.

Watlow's syringe heater was developed for the needs of medical injection applications. The special design provides a heated fluid and drug delivery system solution with long operational life which improves system reliability while reducing equipment down time. Watlow's FREEFLEX™ heater unique design places the heating element and sensor directly in contact with the perimeter of the tubing to produce efficient temperature control of the tube contents. The FREEFLEX heater eliminates the need for heated reservoir systems in many applications.



Air Heaters


Watlow’s air heaters can be used to prevent freezing and condensation in electrical and mechanical housing or can be placed in ducts for forced air heating. Watlow has developed a line of process air heaters that offer performance and versatility in medium to low temperature applications. This rugged and reliable line of industrial heaters efficiently conducts heat.


High Temperature Heaters


These high-temperature heaters are used for extreme high temperature applications. The heaters fit applications such as the construction of furnaces and chambers. Watlow leads the industry in developing high-temperature heating technologies and products in various sizes and constructions to fit a broad range of processes and applications. Watlow's MULTICELL™, FIREROD®, tubular and ceramic fiber heaters offer capabilities such as ultra-fast ramp rates, precise temperature uniformity and high temperatures for applications requiring low thermal mass. Heaters are sized and designed to accommodate small to large applications and various environmental conditions.


Specialty Heaters


These specialty heaters are commonly used for high temperature applications or in cases where high watt densities are required. These versatile heating elements can be formed or machined to fit precise heating applications. Watlow specialty heaters are designed for thermal applications where high performance is required, and fast response and uniformity are essential.

Specialty heaters from Watlow have design flexibility to meet different applications requiring different construction methods. This flexibility allows the heaters to be configured in a variety of shapes and sizes depending on the application.



Strip / Clamp-on Heaters


Bolted or clamped to flat surfaces these heaters can provide freeze or moisture protection. These heaters can be attached to tank or vessel walls for warming. Watlow's strip/clamp-on heaters are a versatile solution for a number of applications. They can be bolted or clamped to a solid surface for freeze and moisture protection, food warming and other applications. These heaters make use of the most advanced heat construction techniques.


Band / Barrel Heaters


These heaters can be clamped to most any cylindrical surfaces. The materials used in the construction of these heaters allows them to be used at temperatures up to 1400°F (760°C) or used at low temperatures for freeze protection. Watlow's line of band/barrel heaters are available for fast delivery and can be easily installed into original equipment manufacturer (OEM) and end user applications. This variety of heaters allows the user to specify the construction needed to result in the best heat solution.




Saturday, July 18, 2009

Electric Heating Elements

electric tubular elements by Watlow
Electric Heating Elements make the industrial world Hot.

Anderson-Bolds has been selling electric Heating Elements since 1934.
Electric Heating elements are a very simple yet extremely effective way to heat in the industrial work place as well as commercially and in the home.

Electric heating elements can be applied in just about every facet of industrial heating and commercial heating, from surface heating, to tank heating, air heating, drying, heat treating, freeze protection, cooking, air conditioning and frost prevention.

The heating element itself is very simple, made of three main parts, a resistance wire, insulator and metallic sheath. The element then functions under Ohms Law with the relationships of Resistance (ohms), current (amperes), watts and volts. Which one of these can be the constant?
To make an element the three main parts mentioned above are brought together, the sheath material is usually in a tube form (except for plastic cable and strip heaters) and hung in a vertical fashion up to 30 or 40 feet and the resistance wire is then also hung through the center of the tube with spacers at each end (a plug on the bottom end) and stretched taught to keep it centered in the sheath tube. The insulator material is then entered into the tube gently, the material is usually magnesium oxide or MGO. [MGO has the two properties necessary to be very good at its job, to insulate the metal sheath from the electrically charged resistance wire AND be a very good heat transfer medium. MGO does this job very well, unless it gets wet.] The MGO is in a fine sand like consistency when poured and shaken into the tube. [The manufacturing plant has to be fairly tall to make the long elements.] The resistance wire is not straight but in a curl formation running up through the center of the sheath tube. The light shaking of the operation allows the MGO to get in between the curls of the wire to fill all the gaps. No air gaps can be present with the element.

After sufficient time on the vibrators or shakers the filled tubes are capped off and removed and taken to the rollers or presses. The elements are now pressed and squeezed to the desired diameter. There are two other results to this operation, the element is lengthened as it is squeezed and the MGO gets compressed into a solid and fills all remaining spaces within the element and resistance wire spaces.

The Heating element is now ready to be formed into the correct shape, be it straight, hairpin, "M" shaped or any other shape desired for the application. After the element is shaped it is repressed to consolidate any of the MGO that has separated and then terminations are added to the ends of the element.

Heating elements can have sheath materials of Iron, copper, stainless steel, incoloy, inconel, monel or any material needed for temperature ratings or corrosion resistance. The common material are copper for water heating, iron for oil heating, and stainless or incoloy for higher temperatures or corrosion.

Lets return to Ohm's law which is W=I2R or V=IR or I=W/V
are the common formula's used with heating with resistance heating elements. With W = watts, I = amps, v= volts and R=ohms.

When making a heating element, the resistance is the constant in the actual element. The wire diameter and length is chosen to meet the wattage requirement when a specific voltage is present on the element. However different wattages and amperes can be easily achieved with different applied voltages; this can be good and bad. In short, if the voltage is doubled the wattage is quadrupled and conversely if the voltage is halved, the wattage drops to 1/4 of what is was. Example; an element rated at 1000 watts on 240 volts will be 250 watts when 120 volts is applied or will be 4000 watts if 480 volts is applied. The resistance wire is the fixed constant in a heating element and is the key to manufacturing consistent product.

The ease of which electric heating elements can be used to heat product makes them an excellent choice in all manners of heat, from manufacturing, to water heating, floor heating, pipe heating, coffee makers, heat treating and plastic injection molding.

Of course in a heating system, we need to control the temperature, sense the temperature and apply the voltage required, this items make up a heating system. Another blog will describe this system.

Some of our manufactures of heating elements and heaters include, Watlow, Danfoss, Q'Mark, Chromalox, Brisk Heat and Process Heating.