Tuesday, May 1, 2012

Ohm's Law and Electric Heaters

Ohm's Law is the mathematical representation of electricity with regard to Voltage, Current, Resistance and Power (or Watts).  This is required information to know when sizing electric heaters, heating elements, electric water heaters and any high amperage appliances.

Anderson-Bolds Ohms Law Calculator (with 3 phase calculations too)

E = Voltage (Volts)
I  =  Current or Amps
R = Resistance (Ohms)
W = Watts (Power)

Formulas:

W = E x I 
W = I2 x R
W = E2 / R
I = W / E
I = (W / R)2
I = E ÷ R 
E = (W x R)2
E = W / I
E = I x R
R = E2 / W
R = W / I2
R = E ÷ I








What is Ohm's Law:
Ohm's Law is made from 3 mathematical equations that shows the relationship between electricvoltage, current and resistance.

What is voltage? An anology would be a huge water tank filled with thousands of gallons of water high on a hill.
The difference between the pressure of water in the tank and the water that comes out of a pipe connected at the bottom leading to a faucet is determined by the size of the pipe and the size of the outlet of the faucet. This difference of pressure between the two can be thought of as potential Voltage.

What is current? An analogy would be the amount of flow determined by the pressure (voltage) of the water thru the pipes leading to a faucet. The term current refers to the quantity, volume or intensity of electrical flow, as opposed to voltage, which refers to the force or "pressure" causing the current flow.

What is resistance? An analogy would be the size of the water pipes and the size of the faucet. The larger the pipe and the faucet (less resistance), the more water that comes out! The smaller the pipe and faucet, (more resistance), the less water that comes out! This can be thought of as resistance to the flow of the water current.
All three of these: voltage, current and resistance directly interact in Ohm's law.
Change any two of them and you effect the third.

Info: Ohm's Law was named after Bavarian mathematician and physicist Georg Ohm.
Ohm's Law can be stated as mathematical equations, all derived from the
same principle.
In the following equations,
V is voltage measured in 
volts (the size of the water tank),I is current measured in amperes (related to the pressure (Voltage) of water thru the pipes and faucet) and R is resistance measured in ohms as related to the size of the pipes and faucet:

V = I x R  (Voltage = Current multiplied by Resistance)
R = V / I  (Resistance = Voltage divided by Current)
 I = V / R  (Current = Voltage Divided by Resistance)


Ohm's Law defines the relationships between (P) power, (E) voltage, (I) current, and (R) resistance. One ohm is the resistance value through which one volt will maintain a current of one ampere.

( I ) Current is what flows on a wire or conductor like water flowing down a river. Current flows from negative to positive on the surface of a conductor. Current is measured in (A) amperes or amps.

( E ) Voltage is the difference in electrical potential between two points in a circuit. It's the push or pressure behind current flow through a circuit, and is measured in (V) volts.

( R ) Resistance determines how much current will flow through a component. Resistors are used to control voltage and current levels. A very high resistance allows a small amount of current to flow. A very low resistance allows a large amount of current to flow. Resistance is measured in  ohms.

( P ) Power is the amount of current times the voltage level at a given point measured in wattage or watts.




Thursday, March 1, 2012

ATC Power Alert - UPA's ~ Voltage Indication Device


Anderson-Bolds can provide the new ATC Power Alerts.

You can email us a request for quote with this form.

The UPA-100 Power Alert reduces the risk of electrical arc flash by pre-verifying the electrical isolation from outside of a control panel. Hardwired to the circuit breaker or main disconnect, the UPA flashes whenever voltage is present. Engineered with redundant circuitry, the Power Alert is powered by the same voltage that it indicates. The eight detector UPA-100 visually alerts to the presence of dangerous AC or DC (Stored Energy) potentials occurring between any combination of the four monitored input lines (L1, L2, L3, GND).

The UPA 130 Power Alert reduces the risk of electrical arc flash by pre-verifying the electrical isolation from outside of a control panel. Hardwired to the circuit breaker or main disconnect, the UPA flashes whenever voltage is present. Engineered with redundant circuitry, the Power Alert is powered by the same voltage that it indicates. The eight detector UPA-130 visually alerts to the presence of dangerous AC or DC (Store Energy) potentials occurring between any combination of the four monitored input lines (L1, L2, L3, GND).

The UPA 130S Power Alert reduces the risk of electrical arc flash by pre-verifying the electrical isolation from outside of a control panel. Hardwired to the circuit breaker or main disconnect, the UPA lights at a steady statewhenever voltage is present. Engineered with redundant circuitry, the Power Alert is powered by the same voltage that it indicates. The eight detector UPA-130S visually alerts to the presence of dangerous AC or DC (Store Energy) potentials occurring between any combination of the four monitored input lines (L1, L2, L3, GND).

The UPA 13 0DIV 2is Class 3, Division 2 FM approved for use in hazardous environments. The UPA 130 DIV2 Power Alert reduces the risk of electrical arc flash by pre-verifying the electrical isolation from outside of a control panel. Hardwired to the circuit breaker or main disconnect, the UPA flashes whenever voltage is present. Engineered with redundant circuitry, the Power Alert is powered by the same voltage that it indicates. The eight detector UPA-130 visually alerts to the presence of dangerous AC or DC (Store Energy) potentials occurring between any combination of the four monitored input lines (L1, L2, L3, GND).

With nominal 3-phase line voltage applied, a flashing green NORMAL LED gives positive indication of a good fuse and integrity of the wire connection to each side of the fuse. A flashing red FAULT LED gives positive indication of an unconnected or open fuse, or a BFA wiring fault that needs corrected such as a lost connection to either side of the fuse or mismatched line and load wires. When phase loss occurs, both FAULT and NORMAL LEDS will extinguish. The BFA will continue to indicate the status of the fuse during a phase loss if a regenerated voltage is produced on the open phase from a rotating motor.

The ATC Diversified Electronics GFD Series is intended for the use on ungrounded systems to detect and indicate the phase of the first ground fault condition. This enables corrective action to avoid the potential hazards resulting from a second ground fault. With nominal 3 phase line voltage applied, a flashing NORMAL green LED gives indication of a non-fault condition and integrity of the wire connection to the corresponding phase. A flashing red LED gives positive FAULT indication of either a phase-to-ground fault, or a lost connection to the corresponding phase.


SERIES PART NUMBER DESCRIPTION PRICE
UPA-100 Series UPA-100 Universal Power Alert $111.00
UPA-100 Series UPA-WP100 ANSI Warning Plate $7.00
UPA-130 Series UPA-130 Universal Power Alert $111.00
UPA-130 Series UPA-130S Universal Power Alert-Solid On $135.00
UPA-130 Series UPA-130DIV2 Universal Power Alert- ClassI,Division2 $149.00
UPA-130 Series UPA-130GOV Universal Power Alert-Government version $135.00
UPA-130 Series UPA-BZL UPA-130 Flush Mount Kit $10.00
UPA-100 Series UPA-WP130 ANSI Warning Plate $7.00
BFA Series BFA-100 Fuse Status Indicator $75.00
BFA Series BFA-200 Fuse Status Indicator $75.00
GFD Series GFD-100 Three Phase Ground Fault Display $109.00
GFD Series GFD-200 Three Phase Ground Fault Display $109.00





Prices as of March 1, 2012 and can change at any time.
Call for prices and delivery. 216-360-9800

Thursday, September 3, 2009

UPS - Uninterruptible Power Supply

Green… Green… Green, today that seems to be a constant mantra that we are hearing from various sectors such as Government, Construction, and Consumers. Being Green is not an exotic disease that leaves your complexion looking like a Martian. Rather being Green is about conserving our valuable resources. Our resources are being depleted at a rate that some say will cause us to run out of resources very soon. I don’t know that I would be like Chicken Little running around screaming that the sky is falling, but we do need to take heed to the problems that do exist, and do what we can to conserve the resources we still have.

This brings me to my subject, Efficiency in UPS Systems. As I look through the trade magazines I have noticed that more and more is being talked about having Data Centers and other areas of Critical Power Back Up systems to become more efficient. UPS systems are found in most business’ today whether they be large or small. They are needed to protect the critical power required for Computers, Emergency Lighting Systems, Laboratory Equipment and more. All are using electrical energy to provide an uninterruptible source of power to these critical systems.

In case you haven’t heard, our electrical power generation facilities are being stretched to capacity. Then on top of that we have a Congress that would like to institute a program called Cap and Trade into law. The effect of this will be less energy production and higher prices for what energy we can get. All these possible new regulations and current production capabilities mandates that we need to become more Energy Efficient, this is a must for all of us. Most UPS manufacturers are promoting that their units are energy efficient, but when we begin to compare them side by side you will notice that some do not meet the mark. In the past some have purchased their UPS systems based on Name Brand Recognition alone, this may not be the best approach if you are really interested in getting the best efficiency and performance from a UPS system. Just because a company is large and well known does not mean they have the best equipment. Also saving a buck in the purchase price may end up taking a big bit out of your wallet when paying for wasted electricity for years down the road. Remember the efficiency of the system is what will ultimately save you on your energy bill for back up power, and again in the cost of cooling and cooling capacity, because efficiency means less heat being generated. Also check the output power factor of a UPS unit. This will be the key factor in knowing how much real power (kW) you will have available for your equipment, because you don’t want to be doing this again in a year or so when up grading your servers or add other equipment. The Input Power Factor is extremely important if you are being billed from your utility a power factor penalty charge. Check out the Harmonic feed back level because this can cause problems with other equipment up stream from the UPS. All of these factors will also play a part in Generator selection.

When selecting a UPS you must first know what power requirements you need for today and tomorrow. What amount of floor space will you be willing to allocate for this equipment. How much Back UP Time will be required because this will dictate the battery requirements and additional space for their placement. Think about peripheral equipment such as Maintenance Bypass Switches, Transformers, Surge Suppression Devices, Power Distribution Units, UPS Management Software, Tie-Cabinets (Parallel Systems), and Air Conditioning.


UPS units come in many different sizes and typology. The most popular systems are True On Line Systems or Duel Conversion systems. These will provide you with the best protection and power conditioning for your equipment.

We have many different brands for you to choose from depending on your application requirements. If you want the best system for your application give us a call and we can help you identify your systems requirements and select the best UPS for the job. We deal in UPS systems daily as well as power related problems, and we are familiar with the changes that are occurring in the industry. Call Syd Orr at Anderson Bolds today for more information.

Anderson-Bolds

Saturday, June 6, 2009

Watlow Power Controls

Anderson-Bolds sells Watlow Power Controls.

Watlow solid state power controllers complement the rapid switching required by PID temperature controls and help deliver optimum system performance and service life. Available in 1-phase and 3-phase/2-leg and 3-leg configuration, Watlow power controllers meet most industrial heating applications. Random, zero cross or phase angle fire options allow for a variety of applications.






















DIN-A-MITE® SCR

The DIN-A-MITE family is the ideal solid state replacement for mercury displacement relays (MDRs) in an easy-to-install, compact, touch-safe package. The solid state power controllers provides SCR control, heatsink, wiring and touch-safe exterior in one package. By designing the DIN-A-MITE as a total power controller unit, the need to prep wires for terminals, locate the right heatsink and determine adequate terminations is eliminated. It's a complete package you can install easily with CONTROL CONFIDENCE®.

Four DIN-A-MITE styles meet most power controller needs with ratings from 18 to 100 amps with voltages from 24 to 600V~(ac). The four models match load requirements with 1-phase, 3-phase/2-leg and 3-phase/3-leg switching. The controllers also provide a convenient DIN-rail and sub-panel mount package.

ControllersAmpsConfigurationsFiring Options
DIN-A-MITE AUp to 25 ampsSingle-PhaseContactor or Burst Fire
DIN-A-MITE BUp to 40 ampsSingle- & Three-PhaseContactor or Burst Fire
DIN-A-MITE CUp to 80 ampsSingle- & Three-PhaseContactor, Bust, Phase
DIN-A-MITE DUp to 100 ampsSingle-PhaseContactor or Burst Fire

Applications

  • Semiconductor processing
  • Plastics processing
  • Heat treating
  • Drying ovens
  • Foodservice equipment
  • Petroleum/chemical
  • Lighting equipment
  • Glass processing
  • Furnace/oven
POWER SERIES Microprocessor-based SCR
  • Ratings from 65 to 250 amperes
  • Offers extensive system and heater diagnostics features and agency approvals

For over thirty years Watlow® has been manufacturing solid state power controllers. Watlow's new POWER SERIES represents the latest in SCR power controller technology. This microprocessor-based product offers features and application flexibility unmatched by any other SCR power controller on the market today.

Capabilities include single-phase and three-phase models from 65 to 250 amps. Field configurable phase angle or zero-cross firing improves application flexibility on site where you need it. 50/60Hz independent operation means you can operate almost everywhere in the world without special calibration considerations. Serial communications utilizing Modbus® protocol allow for remote control setup, and monitoring of load status from a nearby computer station or control room.

On-board semiconductor fusing improves reliability by protecting the SCRs from heater short circuits. Plus, on-board heater bakeout and control diagnostics can help eliminate initial start up problems. All this in a touch-safe package that can be quickly and easily mounted in your control cabinet.

FeaturesBenefits
Microprocessor-based technology
  • Extremely versatile, field configurable
Snap-fit on a pre-mounted plate
  • Easy installation
Models 65 through 250 amp ratings
  • Handles a wide range of loads
Adjustable soft start
  • Application flexibility
Heater and control diagnostics capabilities
  • Monitor actual heater and control performance
Electrically touch-safe package
  • Increased safety for installer and users
Serial communications with Modbus® RTU protocol
  • Computer control and/or monitoring
Multi-zone capability
  • Increased application flexibility, reduced panel space

Applications

  • Semiconductor processing
  • Plastics processing
  • Heat treating
  • Drying ovens
  • Food processing
  • Petroleum/chemical
  • Lighting equipment
  • Furnace/oven
  • CSA, VDE and UL® recognized contactor
  • Ratings from 18 to 50 amperes single phase
  • Single solid state relays from 10 to 75 amperes

The new SERIES CZR solid state contactor from Watlow®provides a low-cost, highly compact and versatile solid state option for controlling electric heat. With DIN-rail and back panel mounting standard on every controllers, the CZR allows for simple and quick installation.

The extensive capabilities of the SERIES CZR include single-phase, 24 to 50 amp zero-cross and random switching up to 600V~ (see output rating curve). The unique integrated design removes the guesswork associated with selecting a proper heat sink and precise terminations for the application.

This controller holds many agency approvals and is ideal for applications that require UL®, CSA and CE approvals. SERIES CZR contactors are available inVac/dc (ac/dc) input contactor versions. All configurations are model number dependent and factory selectable.

The SERIES CZR is reliably backed by a two-year warranty from Watlow.

FeaturesBenefits
DIN-rail or standard panel mount
  • Versatile, quick and low-cost installation
Compact size
  • Reduces panel space; less cost
Touch-safe terminals
  • Increases safety for installer and operator
Mercury free
  • Environmentally safe
Faster switching with solid state
  • Saves energy and extends heater life
UL® 508 recognized, CSA LR700195 certified and CE 60950, VDE 0805 applied for
  • Applications requiring agency approval
Back-to-back SCR design
  • Rugged design

Applications

  • Semiconductor processing
  • Plastics processing
  • Heat treating
  • Drying ovens
  • Food processing
  • Petroleum/chemical
  • Lighting equipment
  • Furnace/oven
When it comes to power control, Watlow can provide the right controller built with quality in the USA.

Thursday, May 28, 2009

Anderson-Bolds ~ Since 1934

Anderson-Bolds has been in the heating and control business since 1934. Mr. A Anderson and Mr. E Bolds joined forces and combined lines to form the firm. The main product line was Chromalox electric heat and soon followed by ASCO solenoid vales and Fenwal Temperature Controls in 1939.

Throughout the years our goal has been to provide engineering help to our customers whether they are OEM's industrial users or other distributors. We are capable of sizing heaters or drives, providing layouts for snow melting or suggesting automation ideas with our industrial computers or HMI's.

Anderson-Bolds' sales engineers can figure wattage requirements for any heating job, process or comfort or can figure flow and or Cv for valves, solenoid valves, control valves or jet pumps. We are here to help with your problem applications to provide the correct product for the job.

Some of our product lines today are Watlow Heaters, Q'Mark Heaters, Toshiba, Fenwal, Parker Valves, Robertshaw Industrial, Meltric, Penberthy, Automatic Timing and Controls, Barksdale, Carlo Gavazzi, Jefferson Valves, Tapeswitch,  Air King Fans and Danfoss.