Sunday, October 30, 2011

Barksdale Pressure Switches ~ Diaphragm Style

Barksdale Diaphragm Pressure Switches


Barksdale's Diaphragm Pressure Switches offer superior accuracy in a robust package, making them the ideal solution to your industrial pressure
control needs. Diaphragm switches are ideal for applications demanding instrument class accuracy and where pressure pulsations are less than 25 cycles per minute. Available in various pressure ranges up to 150 psi, diaphragm switches are suitable for use in either positive pressure or vacuum applications. Single, and dual, and triple circuit models are available.

Housed models (D1H & D2H) feature a durable, anodized aluminum enclosure with an integrated 1/2" NPT conduit connector,a tamper-resistant cover for the setpoint adjustment screws, and are rated to NEMA 4 as a standard. For applications requiring a highly accurate switch in a durable package, Barksdale's Diaphragm Pressure Switches are the ideal choice.
  • Stripped and housed versions available
  • High accuracy
  • Ideal for pressure or vacuum
  • Easy setpoint adjustment
  • NEMA 4 (Housed Models)
  • Up to 3 setpoints available in one switch
  • Diaphragm SealOption Available

Barksdale's D1T & D2T Terminal Block Diaphragm Pressure Switches offer superior accuracy in a robust package, making them the ideal solution to your industrial pressure control needs. These switches are ideal for applications requiring water-tight, NEMA 4 housings a covered terminal strip and tamper-proof external adjustment. (Factory set models are also available.) With pressure ranges up to 150 psi, these housed diaphragm pressure switches are suitable for use in either positive pressure or vacuum applications. Sin
gle- and dual-circuit models are available. Housed models feature a durable, anodized aluminum enclosure. For applications requiring a highly accurate switch in a durable package, Barksdale's D1T & D2T Terminal Block Diaphragm Pressure Switches are the ideal choice.

  • High reliability
  • High accuracy
  • NEMA 4
  • Ideal for pressure and vacuum applications
  • Single and dual switching capability
  • Tamper-proof external adjustment
  • Diaphragm Seal Option Available
Barksdale's D1X and D2X Explosion Proof Diaphragm Pressure Switches offer high accuracy and reliability, providing an ideal solution for your hazardous locations pressure control requirements. With vacuum and positive pressure ranges to 150 psi, NEMA 4,7,& 9 enclosures, a covered terminal strip and tamper-proof external adjustment, Barksdale D1X and D2X Explosion Proof Diaphragm Pressure Switches meet your needs in a wide variety of applications. These switches are available in single setting or dual control. An internal set screw allows for easy internal adjustment of setpoints. For applications requiring a highly accurate switch in a durable packag
e, Barksdale's Explosion Proof Diaphragm Pressure Switches are the ideal choice.
  • Hermetically sealed
  • Explosion proof housing for hazardous location
  • Tamper proof setpoint adjustment
  • Ideal for pressure or vacuum
  • Diaphragm Seal Option Available
  • High Accuracy and Reliability



Barksdale's CD1H and CD2H Housed Diaphragm Pressure Switches provide an ideal solution for pressure control applications requiring tamper proof external adjustment and environments which require water-tight NEMA 4 housings. These pressure switches are available in single or dual control settings for both positive pressure and vacuum models, to 150 psi. These snap-action switches may be wired normally open or normally closed through a 3/4"-14 NPT conduit connector to free leads to 18". All models feature self-locking set screw adjustment and dials which are calibrated for increasing setting. For applications requiring a highly accurate switch in a durable package, Barksdale's CD1H and CD2H Housed Diaphragm Pressure Switches are the ideal choice. Stripped models are also available.

  • High reliability
  • Extremely versatile
  • Calibrated dial for easy setpoint adjustment
  • Ideal for pressure or vacuum
  • Diaphragm Seal Option Available
Call Anderson-Bolds for all your Pressure switch needs, 216-360-9800

Or visit our BARKSDALE web page.

Coax Valves for Flow Control

Coax Valves from Anderson-Bolds

For over 45 years, the coaxial valves developed by our company have formed a tried and tested element in the control of vacuums and gaseous, liquid, gelatinous, abrasive, contaminated, and aggressive media.

The coaxial valve design allows - as compared to conventional valves - high pressure media to be controlled at high flow rates. Our coaxial valves are available in 2/2 way or 3/2 way versions with threaded or flanged connections. The valves are actuated either by direct-acting solenoid or externally controlled.

  • high cycle life
  • fast actuation
  • compact design
  • maintenance free
  • bi-directional flow
  • pressure balanced
  • back pressure tight
  • installation position optional
  • valves operate from 0 bar upward
  • application with contaminated media


  • co-ax typeorifice
    mm
    connection
    thread NPT
    connection
    flange ANSI
    pressure range
    psi
    Cv
    value
    media
    temperature
    ambient
    temperature
    switch time ms
    open/close
    MK 10DN 101/4 - 3/4-0 - 240 / 6002.9-22°F ... 248°F14°F ... 176°F25 / 25
    MK / FK 15DN 153/8 - 3/4150 / 600 / 15000 - 240 / 600 / 960 / 15005.5-40°F ... 320°F-40°F ... 176°F80 / 80
    MK / FK 20DN 203/4 - 1 1/4150 / 600 / 15000 - 240 / 600 / 960 / 15008.5-40°F ... 320°F-40°F ... 176°F110 / 110
    MK / FK 25DN 251 - 1 1/2150 / 600 / 15000 - 240 / 600 / 960 / 150012.7-40°F ... 320°F-40°F ... 176°F130 / 130
    MK / FK 32DN 321 1/4 - 1 1/2150 / 600 / 15000 - 240 / 600 / 960 / 150016.2-40°F ... 320°F-40°F ... 176°F440 / 250
    MK / FK 40DN 401 1/2 - 2150 / 600 / 15000 - 240 / 600 / 96021.2-40°F ... 320°F-40°F ... 176°F520 / 150
    MK / FK 50DN 5021500 - 24032.2-4°F ... 248°F-4°F ... 176°F400 / 400
    FK 65DN 65-1500 - 24051.8-4°F ... 176°F-4°F ... 176°F600 / 800
    FK 80DN 80-1500 - 24080.5-4°F ... 176°F-4°F ... 176°F600 / 800



    www.anderson-bolds.com

    Sunday, August 7, 2011

    HD Pro TRC High Power GFCIs and ELCIs


    TRC manufacturers High Power Ground Fault and Equipment Fault products for personnel and equipment safety.


    Please view the TRC Safety Ground Fault Video Here.


    The below series of HDPRO units cover 30 and 60 amps and voltages of 277, 480, and 208-240.

    Configured for both in-line and bulk head mount. Engineered to trip within 25 milliseconds. Protects:

    �� Motors �� Pumping Systems �� Pressure Washers Has 2’of cable on both line and load side. To prevent equipment startup after

    GFCI/ELCI trips,manual reset required. Will reset on power restoration following disruption of primary power. 6.10.30TM key enable strip level selection and locking at a trip level with key removal.


    PDF link is Here.


    TRC HD-Pro GFCI / ELCI 24396-001

    Volts/Amps: 277V/30A

    Cord Gauge: 10/3 AWG.

    Trip Level: 6, 10 & 30mA

    Single Phase


    TRC HD-Pro GFCI / ELCI

    24672-001

    Volts/Amps: 480V/60A

    Cord Gauge: 4/4 AWG.

    Trip Level: 6, 10 & 30mA

    Three Phase


    TRC HD-Pro GFCI / ELCI

    24542-001

    Volts/Amps: 208-240V/60A

    Cord Gauge: 4/4 AWG.

    Trip Level: 6, 10 & 30mA

    Three Phase


    TRC HD-Pro GFCI / ELCI

    24846-001

    Volts/Amps: 208-240V/30A

    Cord Gauge: 8/5 AWG.

    Trip Level: 6, 10 & 30mA

    Three Phase


    TRC HD-Pro GFCI / ELCI

    24646-001

    Volts/Amps: 480V/30A

    Cord Gauge: 10/4 AWG.

    Trip Level: 6, 10 & 30mA

    Three Phase


    The below HD Pro models are al 60 amps and come in voltages of 120, 380 and 240.

    Configured for both in-line and bulk head mount. Engineered to trip within 25 milliseconds. Protects:

    �� Motors �� Pumping Systems �� Pressure Washers Has 2’of cable on both line and load side. To prevent equipment startup after

    �� Manufacturing Equipment �� Welders �� Hoists

    ELCI trips, manual reset required. Will reset on power restoration following disruption of primary power.


    PDF link is here.


    TRC HD PRO GFCI / ELCI 24520-001

    �� Volts/Amps: 120V/60A �� Cord Gauge: 4/3 AWG. �� Trip Level: 10 mA �� Single Phase


    TRC HD-RPO ELCI / GFCI 25560-001

    �� Volts/Amps: 380V/60A �� Cord Gauge: 4/4 AWG. �� Trip Level: 30 mA �� Three Phase


    TECHNOLOGY RESEARCH CORP HD PRO ELCI / GFCI 24530-001

    �� Volts/Amps: 240V/60A �� Cord Gauge: 4/4 AWG. �� Trip Level: 10 mA �� Three Phase



    The below TRC HDPRO units are rated 60 amps and 80 amps and have voltages of 208-240, 480 and 600.


    PDF link is here.


    TRC HD PRO HIGH POWER ELCI / GFIC 24786-001

    �� Volts/Amps: 208-240V/80A �� Cord Gauge: 4/4 AWG. �� Trip Level: 6, 10 & 30 mA �� Three Phase


    Technology Research HD-PRO ELCI / GFCI 24946-003

    �� Volts/Amps: 600V/60A �� Cord Gauge: 4/4 AWG. �� Trip Level: 6, 10 & 30 mA �� Three Phase


    HD PRO by TRC High Power GFCI / ELCI 24796-001

    �� Volts/Amps: 480V/80A �� Cord Gauge: 4/4 AWG. �� Trip Level: 6, 10 & 30 mA �� Three Phase


    HD-PRO TRC High Power GFCI / ELCI 24992-001

    �� Volts/Amps: 600V/80A �� Cord Gauge: 4/4 AWG. �� Trip Level: 6, 10 & 30 mA �� Three Phase


    The below TRC Units are EGFPDs and are CSA approved. the units are 30 and 60 amps and 208/240 and 480 volts.

    EGFPD = Equipment Ground Fault Protection Device


    Configured for both in-line and bulk head mount. Engineered to trip within 25 milliseconds. Protects:

    �� Motors �� Pumping Systems �� Pressure Washers To prevent equipment startup after EGFPD or GFCI/ELCI trips, manual reset re-

    �� Manufacturing Equipment �� Welders �� Hoists

    quired. Will reset on power restoration following disruption of primary power. Key en- ables trip level selection and locks at a trip level with key removal.

    The PDF file is here.


    TRC 44110 EGFPD ( CSA Approved)

    �� Volts/Amps: 208-240V/30A �� Trip Level: 10, 30 & 50 mA �� Three Phase


    Technology Research Corporation 44140 EGFPD CSA Approved

    �� Volts/Amps: 208-240V/60A �� Trip Level: 10, 30 & 50 mA �� Three Phase


    TRC 44120 EGFPD ( CSA Approved Device )

    �� Volts/Amps: 480V/30A �� Trip Level: 10, 30 & 50 mA �� Three Phase


    Technology Research Corp. CSA Approved 44130 EGFPD

    �� Volts/Amps: 480V/60A �� Trip Level: 10, 30 & 50 mA �� Three Phase


    The below TRC Units are ELCIs and and GFCIs are 30 and 60 amps and 208/240 and 480 volts and have adjustable trip points of 6-10-30 amperes (amps).

    Configured for both in-line and bulk head mount. Engineered to trip within 25 milliseconds. Protects:

    �� Motors �� Pumping Systems �� Pressure Washers To prevent equipment startup after EGFPD or GFCI/ELCI trips, manual reset re-

    �� Manufacturing Equipment �� Welders �� Hoists

    quired. Will reset on power restoration following disruption of primary power. Key en- ables trip level selection and locks at a trip level with key removal.

    The PDF file is here.


    Technology Research Corporation 44610 GFCI/ELCI

    �� Volts/Amps: 208-240V/30A �� Trip Level: 6,10 & 30 mA �� Three Phase


    TRC 44640 GFCI/ELCI

    �� Volts/Amps: 208-240V/60A �� Trip Level: 6,10 & 30 mA �� Three Phase


    TRC 44620 GFCI/ELCI

    �� Volts/Amps: 480V/30A �� Trip Level: 6,10 & 30 mA �� Three Phase


    Technology Research Corp. 44630 GFCI/ELCI

    �� Volts/Amps: 480V/60A �� Trip Level: 6,10 & 30 mA �� Three Phase


    Our complete list of the HD Pro models by TRC is located here.


    To see Anderson-Bolds' other products please go to www.anderson-bolds.com.




    TECHNICAL DATA

    Friday, July 29, 2011

    SSAC Products

    Timer-DOM 100-240VAC/DC 1A DIPsw 1-1023s 2x2

    The TDU and KSDU Series are encapsulated solid- state, delay-on-make timers that combine digital timing circuitry with universal voltage operation. The TDU offers DIP switch adjustment allowing accurate selection of the time delay over the full time delay range. The KSDU is factory fixed from 0.1s to 10,230s and does not include the DIP switch. These series are excellent choices for process control systems and OEM equipment


    The PLMU Series continuously measures the voltage of each of the three phases to provide protection for 3-phase motors and sensitive loads. Its microcontroller senses under and overvoltage, voltage unbalance, phase loss, and phase reversal. Protection is provided even when regenerated voltages are present. Universal voltage operation and standard base connection allows the PLMU to replace hundreds of competitive part numbers.


    Liquid Level-Drain Dual 120VAC Relay Adj 8Pin

    The LLC5 provides dual probe conductive liquid level control in a convenient octal plug-in package. Models are available for fixed fill or drain operation. Isolated, pulsed DC voltage on the probes prevents electrolytic plating. Less than 1 mA of current is used to sense the presence of conductive liquid between the probes and common. On adjustable units, the sensitivity adjustment eliminates false tripping caused by floating debris and foaming agents.





    Flasher 120VAC 1A 75 fpm 6 inch wires

    The FS100 Series (low amp) may be used to control inductive, incandescent or resistive loads. This series offers a 1A (fullwave) or a 2A (halfwave) steady state, 10A inrush solid-state output and may be ordered with an input voltage of 24 or 120VAC. The FS100 Series offers a factory fixed flash rate of 75 FPM or may be ordered with a fixed, custom flash rate ranging from 45 to 150 FPM.





    Saturday, July 16, 2011

    Fire Shield for College Students ~ PROTECTION from Dorm fires



    Fire Shield is a next generation extension cord with built-in intelligence to sense cord damage and shut off the power before a fire can start. No other extension cord has this capability.
    Industry statistics indicate there is a cord fire approximately every 6 minutes. The most frequent causes of such fires are short circuits, overloading, damage, and/or misuse of extension cords.
    A special shield surrounds each of the insulated conductors of the Fire Shield Extension Cord. The shield is continuously monitored by electronics in the plug head. When a dangerous electrical condition is detected by current leaking to the shield, power is shut off before a fire can start.
    Fire Shield differ from GFCI's and ground conductors. Grounded conductors only provide a path to ground. GFCI’s detect ground faults. Neither detects the breakdown in the insulation of a standard extension cord, which can lead to an arcing condition that may start a fire. By utilizing a sensing shield around the insulated Fire Shield conductors combined with intelligent electronics in the plug head, Fire Shield can detect damage in the cord such as series faults (broken and frayed conductors) and parallel faults (insulation damage between the live conductors), and shut off the power before a fire can start.
    Unintentional misuse of extension cords is the main reason for cord fires. Cords may be crimped, pinched, frayed, overloaded, overheated, or just worn out. Any of these conditions can lead to an extension cord fire. Fire Shield can detect any leakage currents from these conditions and shut off power before a fire can occur.
    The cord fire protection is a function of the special shield and relates to the Fire Shield extension cord only.
    Fire Shiled should be used anywhere you use standard extension cords or power strips; in children’s rooms, pet areas, with space heaters, electric blankets, waterbeds, etc. Children and pets have been known to bite or chew electrical cords. Fire Shield, with its built-in intelligence may provide protection in these circumstances. Fire Shield Safety Extension Cords should also be used during the holidays with Christmas trees and other holiday decorations because of the tendency to overload extension cords.
    Standard surge protectors only provide protection against power surges, which is important. However, standard surge protectors do not provide cord fire prevention. TRC has recently introduced a next generation line of Fire Shield Surge Protectors that not only protects against power surges, but also provides cord fire prevention.
    Fire Shield cords are now required at many colleges as the only power strip allowed in college dorms. This is due to students overloading the strips, or tacking the cords to walls or pinching the cords between doors or around corners. All these issues can and will cause fires.
    Fire Shield cords are patented and UL/CSA approved.

    Tuesday, June 28, 2011

    SSAC Timers-Voltage Monitors

    SSAC timers and voltage Monitors:

    These are three of SSAC's more common items:

    The SSAC TRDU Series is a versatile universal time delay relay with 21 selectable single and dual functions. The dual functions replace up to three timers required to accomplish the same function. Both the function and the timing range are selectable with switches located on the face of the unit. Two LED's indicate input voltage and output status. This device offers full 10 A isolated relay output contacts in either SPDT or DPDT. The TRDU replaces hundreds of part numbers, thereby, reducing your stock inventory requirements.










    The SSAC PLM Series continuously measures the voltage of each of the three phases. It separately senses Undervoltage, Voltage Unbalance (including Phase Loss), and Phase Reversal. Protection is assured during periods of large average voltage fluctuations, or when regenerated voltages are present. Both Delta and Wye systems can be monitored; no connection to neutral is required. 380 V AC and 480 V AC units are encapsulated.
    Operation
    The output relay is energized and the LED glows when all voltages are acceptable and the phase sequence is correct. Under and unbalanced voltages (including phase loss) must be sensed for a continuous trip delay period before the relay and the LED are de-energized. Re-energization is automatic upon correction of the fault condition. The output relay will not energize if a fault condition is sensed as power is applied.















    The SSAC TDR Series of time delay relays are comprised of digital circuitry and a separate oscillator to provide high accuracy and stability. The ON and OFF delays are selected by means of ten binary switches, which allow the setting of the desired delay the first time and every time. Full 10 A isolated DPDT output contacts.
    Operation
    Upon application of input voltage, the output relay is energized and the ON time begins. At the end of the ON time, the output de-energizes and the OFF time begins. At the end of the OFF time, the output relay is energized and the cycle repeats as long as input voltage is applied. The OFF time may be the first delay in recycling timers. Reset: Removing input voltage resets the output and time delays, and returns the sequence to the first delay.














    Overview
    SSAC designs and manufactures electronic controls for original equipment manufacturers: commercial appliances, heating, ventilating, air conditioning and refrigeration equipment, vending equipment, pumping equipment, elevators, etc.; for process control and automation designers; obstruction lighting control designers; and for a large group of industrial customers and service contractors. Sales representatives and stocking distributors are located throughout the world.

    An ISO 9001 Company (view ISO certificate)
    For more than 30 years, SSAC has achieved new levels of product, quality, and service. Our customers demand quality and they get it. SSAC was the first North American Timers and Controls Company to have an ISO 9001 Registered quality system in place. Our ISO 9001 Quality Management System monitors all aspects of the business process: from the design process to purchasing, incoming material to shipment and customer service. At SSAC we design quality into our products. All of our processes are documented for sustainability and customer satisfaction. Our goal is to make every customer completely satisfied with the best products and services through continuous improvement and employee involvement.

    Time Delay Relays, Encapsulated Timing Modules, Universal Timers, Alternating Relays, Voltage Monitors, Current Sensors and Monitors, Motor Winding Monitors, Liquid Level Controls, Flashers, Tower & Obstruction Lighting Controls, and Accessories. Most of these controls are available for surface and 35 mm DIN rail mounting. The connection options: screw terminals, octal sockets or 0.25 male quick connects, provide solutions for all types of OEM equipment and custom panels.
    216-360-9800