Saturday, November 5, 2011

Gavazzi PA Through Beam Sensors


Carlo Gavazzi offers a large range of photoelectric sensors which are used extensively on packaging machinery, automatic door systems, factory automation, and in car washes. Our sensors are available in diffuse reflective, background suppression, reto-reflective, polarized, through beam, clear object detection, and colour recognition.

We also offer a range of fiber-optic type sensors for applications where a conventional sensor cannot be used (space restrictions, temperature, atmosphere).




Carlo Gavazzi and Anderson-Bolds bring you a new simple Photo Electric sensor design.  The Carlo Gavazzi Radial design is new to the industry.  This is the Carlo Gavazzi PA series Photo Eye or Photo Electric Sensor / switch.


The Carlo Gavazzi PA18C.T... is part of a family of inexpensive general purpose through beam sensors in industrial standard 18 mm cylindrical ABS housing. The sensors are useful in applications where high- accuracy detection as well as small size is required.

The Compact housing and high power LED work well for an excellent performance-size ratio. The potentiometer used for adjustment of the sensitivity makes the sensors highly flexible. The output type is PNP or NPN and the output switching function is NC and NO.

Features
• Miniature sensor range
 • Range: 20m (Axial), 16 m (Radial)
 • Potentiometer sensitivity adjustment
 • Modulated, infrared light 850 nm
 • Supply voltage: 10 to 30 VDC
 • Output: 100 mA, PNP or NPN, N.C. & N.O.
 • Degree of protection IP67, IP69K
 • LED indication for output, stability and power ON
 • Protection: reverse polarity, short circuit and transients
 • Plug and cable versions
 • Excellent EMC performance
 • M18 Housing ( and industry standard )
• ECOLAB – CE – UL – cUL Approvals

Specifications

Environmental Installation category III (IEC 60664/60664A; 60947-1)
Environmental Pollution degree 3 (IEC 60664/60664A; 60947-1)
Environmental Degree of protection IP 67, IP 69K

Rated operating distance (Sn)
Axial type (A)   Up to 20 meters
Radial type (R) Up to 16 meters

Ambient temperature
Operating   -25° to +60°C (-13° to +140°F)
Storage      -40°to +70°C (-40°to +158°F)

Vibration  10 to 55 Hz, 0.5 mm/7.5 g (IEC 60068-2-6)
Rated insulation voltage  500 VAC (rms) IEC protection class III
Housing material
Body  ABS, grey
Front material   PMMA, red
Connection
Cable  PVC, grey, 2 m 4x0.25mm2,Ø=4.5mm
Plug   M12, 4-pin (CONM14NF-series)
Indication - Receiver
Output ON   LED, yellow
Signal stability and power ON  LED, green
Indication - Emitter
Power Supply ON   LED, Green
Signal stability and power ON  LED, Green

Light spot Diameter  Ø 164 mm @ 3.25 m
Light source  LED, 850 nm
Light type  Infrared, modulated

 Series PA thru beam sensors by Carlo Gavazzi as supplied by Anderson-Bolds


Ordering no. NPN Make & break switching - through beam switch receivers
PA 18 CAT 20 NASA       Axial Style with cable      ( PA18CAT20NASA )
PA 18 CAT 20 NAM1SA  Axial Style with Plug       ( PA18CAT20NAM1SA )
PA 18 CRT 16 NASA       Radial Style with cable   (  PA18CRT16NASA )
PA 18 CRT 16 NAM1SA  Radial Style with plus     ( PA18CRT16NAM1SA )

Ordering no. PNP Make & break switching - through beam switch receivers
PA 18 CAT 20 PASA        Axial Style with cable      ( PA18CAT20PASA )
PA 18 CAT 20 PAM1SA   Axial Style with plug        ( PA18CAT20PAM1SA )
PA 18 CRT 16 PASA      Radial Style with Cable   ( PA18CRT16PASA )
PA 18 CRT 16 PAM1SA   Radial Style with plug     ( PA18CRT16PAM1SA )

Emitters:
PA 18 CAT 20        Axial Style with cable  ( PA 18 CAT 20 )
PA 18 CAT 20M1   Axial Style with Plug       (  PA 18 CAT 20M1 )
PA 18 CRT 16        Radial Style with cable   (  PA 18 CRT 16 )
PA 18 CRT 16M1   Radial Style with plug     (  PA 18 CRT 16M1 )

Accessories
Connector type CONG1A.. / CONM14NF.. series Reflector type ER.. - to be purchased separately

Anderson-Bolds authorized Distributor for Carlo Gavazzi.
Located in Ohio with offices in Cincinnati, Cleveland and Columbus
216-360-9800 ~ 513-528-5680 ~ 614-885-3933
info@anderson-bolds.com



Sunday, October 30, 2011

Barksdale Pressure Switches ~ Diaphragm Style

Barksdale Diaphragm Pressure Switches


Barksdale's Diaphragm Pressure Switches offer superior accuracy in a robust package, making them the ideal solution to your industrial pressure
control needs. Diaphragm switches are ideal for applications demanding instrument class accuracy and where pressure pulsations are less than 25 cycles per minute. Available in various pressure ranges up to 150 psi, diaphragm switches are suitable for use in either positive pressure or vacuum applications. Single, and dual, and triple circuit models are available.

Housed models (D1H & D2H) feature a durable, anodized aluminum enclosure with an integrated 1/2" NPT conduit connector,a tamper-resistant cover for the setpoint adjustment screws, and are rated to NEMA 4 as a standard. For applications requiring a highly accurate switch in a durable package, Barksdale's Diaphragm Pressure Switches are the ideal choice.
  • Stripped and housed versions available
  • High accuracy
  • Ideal for pressure or vacuum
  • Easy setpoint adjustment
  • NEMA 4 (Housed Models)
  • Up to 3 setpoints available in one switch
  • Diaphragm SealOption Available

Barksdale's D1T & D2T Terminal Block Diaphragm Pressure Switches offer superior accuracy in a robust package, making them the ideal solution to your industrial pressure control needs. These switches are ideal for applications requiring water-tight, NEMA 4 housings a covered terminal strip and tamper-proof external adjustment. (Factory set models are also available.) With pressure ranges up to 150 psi, these housed diaphragm pressure switches are suitable for use in either positive pressure or vacuum applications. Sin
gle- and dual-circuit models are available. Housed models feature a durable, anodized aluminum enclosure. For applications requiring a highly accurate switch in a durable package, Barksdale's D1T & D2T Terminal Block Diaphragm Pressure Switches are the ideal choice.

  • High reliability
  • High accuracy
  • NEMA 4
  • Ideal for pressure and vacuum applications
  • Single and dual switching capability
  • Tamper-proof external adjustment
  • Diaphragm Seal Option Available
Barksdale's D1X and D2X Explosion Proof Diaphragm Pressure Switches offer high accuracy and reliability, providing an ideal solution for your hazardous locations pressure control requirements. With vacuum and positive pressure ranges to 150 psi, NEMA 4,7,& 9 enclosures, a covered terminal strip and tamper-proof external adjustment, Barksdale D1X and D2X Explosion Proof Diaphragm Pressure Switches meet your needs in a wide variety of applications. These switches are available in single setting or dual control. An internal set screw allows for easy internal adjustment of setpoints. For applications requiring a highly accurate switch in a durable packag
e, Barksdale's Explosion Proof Diaphragm Pressure Switches are the ideal choice.
  • Hermetically sealed
  • Explosion proof housing for hazardous location
  • Tamper proof setpoint adjustment
  • Ideal for pressure or vacuum
  • Diaphragm Seal Option Available
  • High Accuracy and Reliability



Barksdale's CD1H and CD2H Housed Diaphragm Pressure Switches provide an ideal solution for pressure control applications requiring tamper proof external adjustment and environments which require water-tight NEMA 4 housings. These pressure switches are available in single or dual control settings for both positive pressure and vacuum models, to 150 psi. These snap-action switches may be wired normally open or normally closed through a 3/4"-14 NPT conduit connector to free leads to 18". All models feature self-locking set screw adjustment and dials which are calibrated for increasing setting. For applications requiring a highly accurate switch in a durable package, Barksdale's CD1H and CD2H Housed Diaphragm Pressure Switches are the ideal choice. Stripped models are also available.

  • High reliability
  • Extremely versatile
  • Calibrated dial for easy setpoint adjustment
  • Ideal for pressure or vacuum
  • Diaphragm Seal Option Available
Call Anderson-Bolds for all your Pressure switch needs, 216-360-9800

Or visit our BARKSDALE web page.

Coax Valves for Flow Control

Coax Valves from Anderson-Bolds

For over 45 years, the coaxial valves developed by our company have formed a tried and tested element in the control of vacuums and gaseous, liquid, gelatinous, abrasive, contaminated, and aggressive media.

The coaxial valve design allows - as compared to conventional valves - high pressure media to be controlled at high flow rates. Our coaxial valves are available in 2/2 way or 3/2 way versions with threaded or flanged connections. The valves are actuated either by direct-acting solenoid or externally controlled.

  • high cycle life
  • fast actuation
  • compact design
  • maintenance free
  • bi-directional flow
  • pressure balanced
  • back pressure tight
  • installation position optional
  • valves operate from 0 bar upward
  • application with contaminated media


  • co-ax typeorifice
    mm
    connection
    thread NPT
    connection
    flange ANSI
    pressure range
    psi
    Cv
    value
    media
    temperature
    ambient
    temperature
    switch time ms
    open/close
    MK 10DN 101/4 - 3/4-0 - 240 / 6002.9-22°F ... 248°F14°F ... 176°F25 / 25
    MK / FK 15DN 153/8 - 3/4150 / 600 / 15000 - 240 / 600 / 960 / 15005.5-40°F ... 320°F-40°F ... 176°F80 / 80
    MK / FK 20DN 203/4 - 1 1/4150 / 600 / 15000 - 240 / 600 / 960 / 15008.5-40°F ... 320°F-40°F ... 176°F110 / 110
    MK / FK 25DN 251 - 1 1/2150 / 600 / 15000 - 240 / 600 / 960 / 150012.7-40°F ... 320°F-40°F ... 176°F130 / 130
    MK / FK 32DN 321 1/4 - 1 1/2150 / 600 / 15000 - 240 / 600 / 960 / 150016.2-40°F ... 320°F-40°F ... 176°F440 / 250
    MK / FK 40DN 401 1/2 - 2150 / 600 / 15000 - 240 / 600 / 96021.2-40°F ... 320°F-40°F ... 176°F520 / 150
    MK / FK 50DN 5021500 - 24032.2-4°F ... 248°F-4°F ... 176°F400 / 400
    FK 65DN 65-1500 - 24051.8-4°F ... 176°F-4°F ... 176°F600 / 800
    FK 80DN 80-1500 - 24080.5-4°F ... 176°F-4°F ... 176°F600 / 800



    www.anderson-bolds.com

    Sunday, August 7, 2011

    HD Pro TRC High Power GFCIs and ELCIs


    TRC manufacturers High Power Ground Fault and Equipment Fault products for personnel and equipment safety.


    Please view the TRC Safety Ground Fault Video Here.


    The below series of HDPRO units cover 30 and 60 amps and voltages of 277, 480, and 208-240.

    Configured for both in-line and bulk head mount. Engineered to trip within 25 milliseconds. Protects:

    �� Motors �� Pumping Systems �� Pressure Washers Has 2’of cable on both line and load side. To prevent equipment startup after

    GFCI/ELCI trips,manual reset required. Will reset on power restoration following disruption of primary power. 6.10.30TM key enable strip level selection and locking at a trip level with key removal.


    PDF link is Here.


    TRC HD-Pro GFCI / ELCI 24396-001

    Volts/Amps: 277V/30A

    Cord Gauge: 10/3 AWG.

    Trip Level: 6, 10 & 30mA

    Single Phase


    TRC HD-Pro GFCI / ELCI

    24672-001

    Volts/Amps: 480V/60A

    Cord Gauge: 4/4 AWG.

    Trip Level: 6, 10 & 30mA

    Three Phase


    TRC HD-Pro GFCI / ELCI

    24542-001

    Volts/Amps: 208-240V/60A

    Cord Gauge: 4/4 AWG.

    Trip Level: 6, 10 & 30mA

    Three Phase


    TRC HD-Pro GFCI / ELCI

    24846-001

    Volts/Amps: 208-240V/30A

    Cord Gauge: 8/5 AWG.

    Trip Level: 6, 10 & 30mA

    Three Phase


    TRC HD-Pro GFCI / ELCI

    24646-001

    Volts/Amps: 480V/30A

    Cord Gauge: 10/4 AWG.

    Trip Level: 6, 10 & 30mA

    Three Phase


    The below HD Pro models are al 60 amps and come in voltages of 120, 380 and 240.

    Configured for both in-line and bulk head mount. Engineered to trip within 25 milliseconds. Protects:

    �� Motors �� Pumping Systems �� Pressure Washers Has 2’of cable on both line and load side. To prevent equipment startup after

    �� Manufacturing Equipment �� Welders �� Hoists

    ELCI trips, manual reset required. Will reset on power restoration following disruption of primary power.


    PDF link is here.


    TRC HD PRO GFCI / ELCI 24520-001

    �� Volts/Amps: 120V/60A �� Cord Gauge: 4/3 AWG. �� Trip Level: 10 mA �� Single Phase


    TRC HD-RPO ELCI / GFCI 25560-001

    �� Volts/Amps: 380V/60A �� Cord Gauge: 4/4 AWG. �� Trip Level: 30 mA �� Three Phase


    TECHNOLOGY RESEARCH CORP HD PRO ELCI / GFCI 24530-001

    �� Volts/Amps: 240V/60A �� Cord Gauge: 4/4 AWG. �� Trip Level: 10 mA �� Three Phase



    The below TRC HDPRO units are rated 60 amps and 80 amps and have voltages of 208-240, 480 and 600.


    PDF link is here.


    TRC HD PRO HIGH POWER ELCI / GFIC 24786-001

    �� Volts/Amps: 208-240V/80A �� Cord Gauge: 4/4 AWG. �� Trip Level: 6, 10 & 30 mA �� Three Phase


    Technology Research HD-PRO ELCI / GFCI 24946-003

    �� Volts/Amps: 600V/60A �� Cord Gauge: 4/4 AWG. �� Trip Level: 6, 10 & 30 mA �� Three Phase


    HD PRO by TRC High Power GFCI / ELCI 24796-001

    �� Volts/Amps: 480V/80A �� Cord Gauge: 4/4 AWG. �� Trip Level: 6, 10 & 30 mA �� Three Phase


    HD-PRO TRC High Power GFCI / ELCI 24992-001

    �� Volts/Amps: 600V/80A �� Cord Gauge: 4/4 AWG. �� Trip Level: 6, 10 & 30 mA �� Three Phase


    The below TRC Units are EGFPDs and are CSA approved. the units are 30 and 60 amps and 208/240 and 480 volts.

    EGFPD = Equipment Ground Fault Protection Device


    Configured for both in-line and bulk head mount. Engineered to trip within 25 milliseconds. Protects:

    �� Motors �� Pumping Systems �� Pressure Washers To prevent equipment startup after EGFPD or GFCI/ELCI trips, manual reset re-

    �� Manufacturing Equipment �� Welders �� Hoists

    quired. Will reset on power restoration following disruption of primary power. Key en- ables trip level selection and locks at a trip level with key removal.

    The PDF file is here.


    TRC 44110 EGFPD ( CSA Approved)

    �� Volts/Amps: 208-240V/30A �� Trip Level: 10, 30 & 50 mA �� Three Phase


    Technology Research Corporation 44140 EGFPD CSA Approved

    �� Volts/Amps: 208-240V/60A �� Trip Level: 10, 30 & 50 mA �� Three Phase


    TRC 44120 EGFPD ( CSA Approved Device )

    �� Volts/Amps: 480V/30A �� Trip Level: 10, 30 & 50 mA �� Three Phase


    Technology Research Corp. CSA Approved 44130 EGFPD

    �� Volts/Amps: 480V/60A �� Trip Level: 10, 30 & 50 mA �� Three Phase


    The below TRC Units are ELCIs and and GFCIs are 30 and 60 amps and 208/240 and 480 volts and have adjustable trip points of 6-10-30 amperes (amps).

    Configured for both in-line and bulk head mount. Engineered to trip within 25 milliseconds. Protects:

    �� Motors �� Pumping Systems �� Pressure Washers To prevent equipment startup after EGFPD or GFCI/ELCI trips, manual reset re-

    �� Manufacturing Equipment �� Welders �� Hoists

    quired. Will reset on power restoration following disruption of primary power. Key en- ables trip level selection and locks at a trip level with key removal.

    The PDF file is here.


    Technology Research Corporation 44610 GFCI/ELCI

    �� Volts/Amps: 208-240V/30A �� Trip Level: 6,10 & 30 mA �� Three Phase


    TRC 44640 GFCI/ELCI

    �� Volts/Amps: 208-240V/60A �� Trip Level: 6,10 & 30 mA �� Three Phase


    TRC 44620 GFCI/ELCI

    �� Volts/Amps: 480V/30A �� Trip Level: 6,10 & 30 mA �� Three Phase


    Technology Research Corp. 44630 GFCI/ELCI

    �� Volts/Amps: 480V/60A �� Trip Level: 6,10 & 30 mA �� Three Phase


    Our complete list of the HD Pro models by TRC is located here.


    To see Anderson-Bolds' other products please go to www.anderson-bolds.com.




    TECHNICAL DATA

    Friday, July 29, 2011

    SSAC Products

    Timer-DOM 100-240VAC/DC 1A DIPsw 1-1023s 2x2

    The TDU and KSDU Series are encapsulated solid- state, delay-on-make timers that combine digital timing circuitry with universal voltage operation. The TDU offers DIP switch adjustment allowing accurate selection of the time delay over the full time delay range. The KSDU is factory fixed from 0.1s to 10,230s and does not include the DIP switch. These series are excellent choices for process control systems and OEM equipment


    The PLMU Series continuously measures the voltage of each of the three phases to provide protection for 3-phase motors and sensitive loads. Its microcontroller senses under and overvoltage, voltage unbalance, phase loss, and phase reversal. Protection is provided even when regenerated voltages are present. Universal voltage operation and standard base connection allows the PLMU to replace hundreds of competitive part numbers.


    Liquid Level-Drain Dual 120VAC Relay Adj 8Pin

    The LLC5 provides dual probe conductive liquid level control in a convenient octal plug-in package. Models are available for fixed fill or drain operation. Isolated, pulsed DC voltage on the probes prevents electrolytic plating. Less than 1 mA of current is used to sense the presence of conductive liquid between the probes and common. On adjustable units, the sensitivity adjustment eliminates false tripping caused by floating debris and foaming agents.





    Flasher 120VAC 1A 75 fpm 6 inch wires

    The FS100 Series (low amp) may be used to control inductive, incandescent or resistive loads. This series offers a 1A (fullwave) or a 2A (halfwave) steady state, 10A inrush solid-state output and may be ordered with an input voltage of 24 or 120VAC. The FS100 Series offers a factory fixed flash rate of 75 FPM or may be ordered with a fixed, custom flash rate ranging from 45 to 150 FPM.





    Saturday, July 16, 2011

    Fire Shield for College Students ~ PROTECTION from Dorm fires



    Fire Shield is a next generation extension cord with built-in intelligence to sense cord damage and shut off the power before a fire can start. No other extension cord has this capability.
    Industry statistics indicate there is a cord fire approximately every 6 minutes. The most frequent causes of such fires are short circuits, overloading, damage, and/or misuse of extension cords.
    A special shield surrounds each of the insulated conductors of the Fire Shield Extension Cord. The shield is continuously monitored by electronics in the plug head. When a dangerous electrical condition is detected by current leaking to the shield, power is shut off before a fire can start.
    Fire Shield differ from GFCI's and ground conductors. Grounded conductors only provide a path to ground. GFCI’s detect ground faults. Neither detects the breakdown in the insulation of a standard extension cord, which can lead to an arcing condition that may start a fire. By utilizing a sensing shield around the insulated Fire Shield conductors combined with intelligent electronics in the plug head, Fire Shield can detect damage in the cord such as series faults (broken and frayed conductors) and parallel faults (insulation damage between the live conductors), and shut off the power before a fire can start.
    Unintentional misuse of extension cords is the main reason for cord fires. Cords may be crimped, pinched, frayed, overloaded, overheated, or just worn out. Any of these conditions can lead to an extension cord fire. Fire Shield can detect any leakage currents from these conditions and shut off power before a fire can occur.
    The cord fire protection is a function of the special shield and relates to the Fire Shield extension cord only.
    Fire Shiled should be used anywhere you use standard extension cords or power strips; in children’s rooms, pet areas, with space heaters, electric blankets, waterbeds, etc. Children and pets have been known to bite or chew electrical cords. Fire Shield, with its built-in intelligence may provide protection in these circumstances. Fire Shield Safety Extension Cords should also be used during the holidays with Christmas trees and other holiday decorations because of the tendency to overload extension cords.
    Standard surge protectors only provide protection against power surges, which is important. However, standard surge protectors do not provide cord fire prevention. TRC has recently introduced a next generation line of Fire Shield Surge Protectors that not only protects against power surges, but also provides cord fire prevention.
    Fire Shield cords are now required at many colleges as the only power strip allowed in college dorms. This is due to students overloading the strips, or tacking the cords to walls or pinching the cords between doors or around corners. All these issues can and will cause fires.
    Fire Shield cords are patented and UL/CSA approved.