Littelfuse TDR Series - Relay-Output, Recycling Time Delay Relay

TDR Series - Relay-Output, Recycling Time Delay Relay

from Littelfuse / SSAC and Anderson-Bolds

Littelfuse Timers, TDRs and Monitors

 

 

 

For a Quote, Please click HERE!

The Littelfuse TDR Series of time-delay relays are comprised of digital circuitry and an isolated, 10A relay output. The on and off delays are selected by means of two, ten position binary switches, which allow the setting of the desired delay to be precise every time.

Operation (Recycling - ON Time First)
Upon application of input voltage, the green LED glows, the output relay is energized, the red LED glows, and the T1 ON time begins. At the end of the ON time, the output deenergizes, the red LED turns OFF and the T2, OFF time begins. At the end of the OFF time, the output relay energizes and the cycle repeats as long as input voltage is applied.
Reset: Removing input voltage resets the output and time delays, and returns the sequence to the first delay.

Operation (Recycling - OFF Time First)
Upon application of input voltage, the green LED glows, the T1 OFF time begins, the load is OFF. At the end of the OFF time, the T2 ON time begins, the load energizes, and the red LED glows. At the end of the ON time the load de-energizes and the red LED turns OFF. The cycle repeats until input voltage is removed.
Reset: Removing input voltage resets the output and the sequence to the OFF time.

Features & Benefits:

ON & OFF time delay settings:   Independent adjustment allows for greater flexibility 

3 Time Ranges Available (0.1s to 2.8h):  Makes it versatile for use in many applications 

Microcontroller based:  Repeat Accuracy + / - 0.1% or 20 ms, whichever is greater; Setting Accuracy + / - 2% or 50 ms, whichever is greater

DIP switch adjustment:  Provides first time setting accuracy

Isolated output contacts Allows control of loads for AC or DC voltages 

LED indication (select models):  Provides visual indication of relay status 

Littelfuse Recycle Timer Series TDR

 

 

  

 

 

 

 

 


Specification:

Time Delay

Type  Digital integrated circuitry

Range:   0.1102.3 s in 0.1 s increments 11023 s in 1 s increments 1010,230 s in 10 s increments 

Repeat Accuracy:  ±0.1 % 

Setting Accuracy:  ±2 %  

Reset Time≤ 150 ms 

Time Delay vs. Temperature & Voltage:  ±5 % 

Indicator:  LED glows during timing; relay is de-energized 

Input 

Voltage12, 24, or 110 V dc; 24, 120, or 230 V ac 

Tolerance:  12 V dc & 24 Vdc/ac-15 %20 %110 V ac/dc to 230 V ac-20 %10 % 

Ac Line Frequency:   50/60 Hz 

Power Consumption:   ≤ 3.25W 

Output 

Type:   Electromechanical relay 

Form:   DPDT 

Rating: 10 A resistive @ 120/240 V ac; 1/3 hp @ 120/240 V ac

Life 

Mechanical - 1 x107; Electrical - 1 x 106 

Protection 

PolarityDc units are reverse polarity protected

Isolation Voltage:  ≥ 1500 V RMS input to output 

Mechanical:

Mounting:  Plug-in socket 

Dimensions:  H 44.45 mm (1.75”); W 60.33 mm (2.38”); D (with socket) 104.78 mm (4.13”)  

Termination:  Octal 8-pin plug-in 

Environmental:

Operating/Storage Temperature-20 °C to 65 °C / -30 °C to 85 °C

Weight:  ≅ 4 oz (113 g)

Littelfuse detail of Dip switches. Timers can have a mix of ranges
 

 

 

 

 

 

 

 

Littelfuse Series TDR Model Numbers 

TDR1A22   12VDC    
ON time first    1-1023 in 1s increments, Off Time: 1-1023 in 1s increments
 
TDR2A23   24VAC   
ON time first    1-1023 in 1s increments, Off Time: 10-10230 in 10s increments
 
ON time first    0.1-1023 in 0.1s increments, Off Time: 0.1-1023 in 0.1s increments
 
TDR4A12   120VAC    
ON time first    0.1-1023 in 0.1s increments, Off Time: 1-1023 in 1s increments
 
TDR4A13   120VAC    
ON time first    0.1-1023 in 0.1s increments, Off Time: 10-10230 in 10s increments
 
ON time first    1-1023 in 1s increments, Off Time: 1-1023 in 1s increments
 
TDR4A23   120VAC    
ON time first    1-1023 in 1s increments, Off Time: 10-10230 in 10s increments
 
ON time first    10-10230 in 10s increments, Off Time: 10-10230 in 10s increments
 
TDR4B22   120VAC    
OFF time first    1-1023 in 1s increments, On Time: 1-1023 in 1s increments
 
TDR4B23   120VAC    
OFF time first    1-1023 in 1s increments, On Time: 10-10230 in 10s increments
 
TDR6A22   230VAC    
ON time first    1-1023 in 1s increments, Off Time: 1-1023 in 1s increments

Accessories:

NDS-8 Octal 8-pin Socket
8-pin 35mm DIN rail or surface mount. Rated at 10A @ 300VAC. Surface mounted with two #6 (M 3.5 x 0.6) screws or snaps onto a 35 mm DIN rail. Uses PSC8 hold-down clips.
 
PSC8 Hold-down Clips  
Securely mounts plug-in controls in any position. Provides protection against vibration. Use with NDS-8 Octal Socket. Sold in pairs.  
 
BZ1 Front Panel Mount Kit 
Provides an easy method of through-the-panel mounting of 8- or 11-pin plug-in timers, flashers, and other controls.
 
C103PM (AL) DIN Rail  
35 mm aluminum DIN rail available in a 36 in. (91.4 cm) length.

For a Quote, Please click HERE!

Anderson-Bolds
216-360-9800
www.anderson-bolds.com

Littelfuse TDR...SSAC TDR...Littelfuse TDR

Wednesday, July 31, 2019

ATC CP Percentage Timers

Anderson-Bolds sells ATC Percentage Timers, Type CP

When Timing is Everything.

Process engineers and machine designers alike turn to the Automatic Timing & Controls division of Marsh Bellofram (ATC) for their industrial timing and control requirements. These highly rugged, high-reliability products are engineered to provide accurate and repeatable timing and monitoring operations in all types of industrial environments, including factory automation, food processing, plastics, packaging, water treatment and many OEM applications. The ATC product family has recently expanded to include 1/16 DIN timers, TC/PID controllers, electromechanical timers, counters, solid state cube and plug-in timers, and time delay relays (TDR).
ATC CP Percentage timer








ATC Percentage Timers are available in several models including the Model CP single circuit repeat cycle timer is a continuous cycling control where the ON or circuit closure time is dial adjusted for a percentage of the total time cycle
About the CP Series Percentage Timer from the Automatic Timing and Controls division of Marsh Bellofram Corporation: For continuous ON-OFF control of electrical circuits, the Model CP Series Percentage Timer is a single circuit repeat cycle timer, offering continuous cycling control where the ON or circuit closure time is dial adjusted for a percentage of the total time cycle.
Applications: Control of pumps, blowers, filters, heating equipment, industrial ovens, laboratory equipment and wherever ON or OFF control is desired as a percentage of the primary fixed total time cycle.
  • Precise Fool-proof Operating Mechanism
  • Eliminates All Engaging Cams And Latches
  • Five Time Ranges From Which To Choose
  • Minimal Panel Space Needed
Click below to purchase or review the specifications.

ATC Percentage Timer, Type CP, 30 second, 120 volts AC


ATC Percentage Timer, Type CP, 60 second, 120 volts AC


ATC Percentage Timer, Type CP, 15 Minute, 120 volts AC


ATC Percentage Timer, Type CP, 30 Minute, 120 volts AC


ATC Percentage Timer, Type CP, 60 Minute, 120 volts AC

Click HERE for the catalog Sheet pdf

Anderson-Bolds
Cleveland, Ohio
216-360-9800
www.anderson-bolds.com

Thursday, May 31, 2018

SSAC Flasher FS152

Littelfuse FS152 Flasher from ANDERSON-BOLDS

The Littelfuse Flasher 152 runs on 120 volts and has 90 Flashes per Minute (FPM) rate.


The FS100 Series (medium power) may be used to control inductive, incandescent, or resistive loads. Input voltages of 24, 120, or 230VAC are available. Fixed flash rates in stock range from 30, 50, 60, and 90 FPM, with custom flash rates ranging from 10 to 300 FPM. Encapsulation provides protection against shock, vibration, and humidity. This group of solid-state flashers has proven reliability with years of use throughout the world.
Operation
Upon application of input voltage, the T2 OFF time begins. At the end of the OFF time, the T1 ON time begins and the load energizes. At the end of T1, T2 begins and the load de-energizes. This cycle repeats until input voltage is removed. 

SSAC/Littel Fuse FS 152 Flasher













Anderson-Bolds
www.anderson-bolds.com
216-360-9800

Sunday, January 31, 2016

ATC 422AR Flip Flop Timer

Anderson-Bolds Stocks the ATC 422AR Flip-Flop / Recycle Timer


Automatic Timing and Controls 422AR100S0X is a recycling Flip-Flop Timer that has on and off times.
The Series 422AR replaces the original 342 Flip Timer and the 422A flip/flop timer. All the ATC timers were capable of different on and off times making them a flip flop timer and not just a recycle timer which tends to have identical on and off times. The ATC 422AR TDR has ranges in seconds, minutes and hours and in each of these ranges you can select 1 second or 10 second, 1 minute or 10 minutes or 1 hour or 10 hours making 6 total ranges. The ON time can be in minutes while the OFF time in seconds, or the ON time in seconds and the OFF time in hours.

The 422AR is a 1/16 DiN timer with a 10 amp relay and plugs into an industry standard octal plug.  So changing an older 422A series to the newer 422AR100SOX timer is as simple and plugging the new one into the old one's socket.


ATC 422AR TDR with Octal Socket

Note that the 422AR is an analog set timer, not digital and it would be difficult to set both the on and off times to exactly the same value (it would be close though).

Use p/n 8258500 for surface/DIN rail socket for the 422AR timer.



The older part numbers that the 422AR100S0X replaces are below.
422A100F10X
422A100F30X
422A500F10X
422A500F30X
342B200F10PX

Please call Anderson-Bolds to order or click on the Timer picture for the link to our online store.

866-360-9810