Showing posts with label pin and sleeve. Show all posts
Showing posts with label pin and sleeve. Show all posts

Monday, October 26, 2015

Meltric deContactors Voltage color coding

Meltric deContactors from Anderson-Bolds provide safe connection of power to motors, pumps, heaters, compressors, HVAC Equipment and welders.
Meltric color codes their Plugs and receptacles based on voltage and pin combination.
Both the inlet and receptacle have the color coding for visual indication that the plugs go together add all as being pinned the same.

216-360-9800
Contact Anderson-Bolds regarding Meltric

1 pole 1 neutral and1 ground - 1P+N+G

110-125 volts 60 Hz  ORANGE
120-127 volts 60 Hz  YELLOW
255-277 volts 60 Hz  GREY
347 volts        60 Hz  RED

Two Poles and 1 Ground  - 2P+G

208-220 volts 60 Hz  BLUE
220-250 volts 60 Hz  ORANGE
440-480 volts 60 Hz  RED
600 volts        60 Hz  BLACK

Two Poles Neutral and 1 Ground  - 2P+N+G

110-125 volts 60 Hz ORANGE
220-250 volts 60 Hz ORANGE
208-220 volts 60 Hz BLUE
255-277 volts 60 Hz RED
440-480 volts 60 Hz RED
347-600 volts 60 Hz BLACK

Three Poles and One Ground - 3P+G

208-220 volts 60 Hz BLUE
220-250 volts 60 Hz ORANGE
440-480 volts 60 Hz RED
600 volts        60 Hz BLACK

Three Poles, One Neutral and One Ground - 3P+N+G

110-125 volts 60 Hz ORANGE
220-250 volts 60 Hz ORANGE
120-127 volts 60 Hz BLUE
208-220 volts 60 Hz BLUE
255-277 volts 60 Hz RED
440-480 volts 60 Hz RED
347-600 volts 60 Hz BLACK









Friday, March 23, 2012

Meltric DSN 30 Part numbers

Anderson-Bolds and Meltric can supply 30 amp Pin and Sleeve connectors.
Meltric DSN plugs and receptacles are also disconnect switches.

If you have a Meltric Part number and you want a quote, please go to our contact FORM HERE

Spare parts are listed below.

61-3A010 DSN30 INLET INTERIOR
61-3A010-B DSN30 MALE INTERIOR BOTTOM
61-3A010-T DSN30 MALE INTERIOR TOP
61-3A011 DSN30 INLET CONTACT (W/PILOTS)
61-3A011-380 DSN30 INLET CONTACT W/O PILOTS
61-3A013 DSN30 HANDLE
61-3A013-1 DSN30 HANDLE
61-3A013-114 DSN30 HANDLE
61-3A013-12 DSN30 HANDLE
61-3A013-34 DSN30 HANDLE W/ 3/4" NPT
61-3A014 DSN30 INLET CASING
61-3A020 DSN30 RECEPTACLE INTERIOR
61-3A020-B DSN30 RECP INTERIOR BOTTOM
61-3A020-T DSN30 FEMALE INTERIOR TOP
61-3A021 DSN30 RECP CONTACT (W/PILOTS)
61-3A021-380 DSN30 RECP CONTACT W/O PILOTS
61-3A023-12 DSN30 CONDUIT BOX
61-3A023-34 DSN30 CONDUIT BOX
61-3A024 DSN30 RECEPTACLE CASING
61-3A024-843 DSN30 REC CASING W/PADLOCK PAW
61-3A027 DSN30 ANGLE, POLY
61-3A053-080-1 DSN30 ANGLE/BOX W/ 1" NPT
61-3A053-080-12 DSN30 ANGLE/BOX
61-3A053-080-34 DSN30 ANGLE/BOX
61-3A126 DSN30 INLET CAP
61-3A346 DSN30 FINGER DRAWPLATE KIT BAG
61-3A826 DSN30 LOCKING CAP
61-3AB26 DSN30 BLUE GASKET
61-3AC26 DSN30 ORANGE GASKET
61-3AJ26 DSN30 YELLOW GASKET
61-3AM26 DSN30 MARECHAL GASKET
61-3AN26 DSN30 BLACK GASKET
61-3AR26 DSN30 RED GASKET

Plugs, Receptacles, handles and angle boxes are below.

63-34042 DSN30 RECEPTACLE
63-34043 DSN30 RECEPTACLE
63-34043-270 DSN30 RECEPTACLE
63-34043-270-NC DSN30 REC W/MICROSWITCH
63-34043-375 DSN30 RECEPTACLE
63-34043-843 DSN30 RECEPTACLE
63-34043-972 DSN30 RECEPTACLE W/2 PILOTS
63-34043-972-348-A188 DSN30 REC W/2 PILOTS, 348 PAWL
63-34043-972-375 DSN30 RECEPTACLE
63-34043-972-NC DSN30 RECEPTACLE W/2 PILOTS
63-34045 DSN30 RECEPTACLE
63-34047 DSN30 RECEPTACLE
63-34047-972 DSN30 RECEPTACLE W/2 PILOTS
63-34072 DSN30 RECEPTACLE
63-34072-270 DSN30 RECEPTACLE W/MICROSWITCH
63-34073 DSN30 RECEPTACLE
63-34073-NC DSN30 RECEPTACLE
63-34075 DSN30 RECEPTACLE
63-34076 DSN30 RECEPTACLE
63-34142 DSN30 RECEPTACLE
63-34143 DSN30 RECEPTACLE
63-34143-972-270 DSN30 RECP 2PILOTS,MICROSWITCH
63-34147 DSN30 RECEPTACLE
63-34162 DSN30 RECEPTACLE
63-34163 DSN30 RECEPTACLE
63-34167 DSN30 RECEPTACLE
63-34167-375 DSN30 RECEPTACLE
63-38042 DSN30 INLET
63-38043 DSN30 INLET
63-38043-338-A188 DSN30 INLET W/ PRL AND
63-38043-972 DSN30 INLET W/2 PILOTS
63-38043-972-A188 DSN30 INLET
63-38045 DSN30 INLET
63-38047 DSN30 INLET
63-38047-972 DSN30 INLET W/2 PILOTS
63-38047-NNF DSN30 INLET
63-38072 DSN30 INLET
63-38073 DSN30 INLET
63-38073-972 DSN30 INLET W/2 PILOTS
63-38075 DSN30 INLET
63-38076 DSN30 INLET
63-38076-NNF DSN30 INLET
63-38142 DSN30 INLET
63-38143 DSN30 INLET
63-38147 DSN30 INLET
63-38147-972-NNF DSN30 INLET W/2 PILOTS
63-38162 DSN30 INLET
63-38163 DSN30 INLET
63-38167 DSN30 INLET

Buy DSN 30 Meltric parts here!

866-360-9810

Saturday, December 17, 2011

Meltric DSN Spec


Anderson-Bolds and Meltric present the DSN series of deContactor. Safety First.

Detailed spec for MELTRIC DECONTACTOR Series Switch Rated Plugs & Receptacles

Note to specifying engineer: In order to specify Meltric DECONTACTOR Series plugs and receptacles, include one or all of the items below in your job specification. The items in bold are exclusive to Meltric Decontactors and thus should be included in the specification wherever practical to avoid substitution of pin and sleeve or twist type devices.

  1. Plugs and receptacles must be listed to UL Subject 2682 'Switch Rated Plugs and Receptacles.' (Alternate for Canada: Plugs and receptacles must be CSA listed to UL Subject 2682 'Switch Rated Plugs and Receptacles').
  2. Plugs and receptacles must have constant pressure butt-contacts with solid silver-nickel tips. Pin and sleeve contacts are not permitted.
  3. Receptacles must have dead front construction: live parts must be inaccessible to thin tool or wire.
  4. Plugs and receptacles must be able to close at least once on a conditional short-circuit current of 65,000A. (Short circuit testing should be performed with RK1 current limiting fuses sized at 400% of the highest full load motor ampacity associated with the device).
  5. Plugs and receptacles must incorporate an integral switching mechanism to ensure the load is broken before the plug is removed from the receptacle.
  6. Plug and receptacle wire terminals must be spring-assisted to prevent loosening due to conductor yielding, shocks, vibrations or thermal cycling.
  7. The minimum environmental rating of plugs and receptacles must be NEMA 3R (DS Series), NEMA 4X and IP 66+67 (DSN Series), or IP67 (DB Series).
  8. Ingress protection must be achieved automatically when the plug is fully inserted into the receptacles, without additional manual operation (except DB Series).
  9. Plugs and receptacles must have a system of different keying positions in order to discriminate between circuits or incompatible operating voltages or frequencies.
  10. Plugs and receptacles installed outdoor must be able to withstand UV radiation.
  11. Plugs and receptacles shall be Meltric Decontactor Series or equal.


866-360-9810