Meltric series DS and DSN Instruction Manual
Anderson-Bolds Sells Meltric deContactors HERE.
www.anderson-bolds.com
216-360-9800
Showing posts with label pin and sleeve. Show all posts
Showing posts with label pin and sleeve. Show all posts
Monday, August 22, 2016
Monday, October 26, 2015
Meltric deContactors Voltage color coding
Meltric deContactors from Anderson-Bolds provide safe connection of power to motors, pumps, heaters, compressors, HVAC Equipment and welders.
Meltric color codes their Plugs and receptacles based on voltage and pin combination.
Both the inlet and receptacle have the color coding for visual indication that the plugs go together add all as being pinned the same.
216-360-9800
Contact Anderson-Bolds regarding Meltric
1 pole 1 neutral and1 ground - 1P+N+G
110-125 volts 60 Hz ORANGE
120-127 volts 60 Hz YELLOW
255-277 volts 60 Hz GREY
347 volts 60 Hz RED
Two Poles and 1 Ground - 2P+G
208-220 volts 60 Hz BLUE
220-250 volts 60 Hz ORANGE
440-480 volts 60 Hz RED
600 volts 60 Hz BLACK
Two Poles Neutral and 1 Ground - 2P+N+G
110-125 volts 60 Hz ORANGE
220-250 volts 60 Hz ORANGE
208-220 volts 60 Hz BLUE
255-277 volts 60 Hz RED
440-480 volts 60 Hz RED
347-600 volts 60 Hz BLACK
Three Poles and One Ground - 3P+G
208-220 volts 60 Hz BLUE
220-250 volts 60 Hz ORANGE
440-480 volts 60 Hz RED
600 volts 60 Hz BLACK
Three Poles, One Neutral and One Ground - 3P+N+G
110-125 volts 60 Hz ORANGE
220-250 volts 60 Hz ORANGE
120-127 volts 60 Hz BLUE
208-220 volts 60 Hz BLUE
255-277 volts 60 Hz RED
440-480 volts 60 Hz RED
347-600 volts 60 Hz BLACK
Meltric color codes their Plugs and receptacles based on voltage and pin combination.
Both the inlet and receptacle have the color coding for visual indication that the plugs go together add all as being pinned the same.
216-360-9800
Contact Anderson-Bolds regarding Meltric
1 pole 1 neutral and1 ground - 1P+N+G
110-125 volts 60 Hz ORANGE
120-127 volts 60 Hz YELLOW
255-277 volts 60 Hz GREY
347 volts 60 Hz RED
Two Poles and 1 Ground - 2P+G
208-220 volts 60 Hz BLUE
220-250 volts 60 Hz ORANGE
440-480 volts 60 Hz RED
600 volts 60 Hz BLACK
Two Poles Neutral and 1 Ground - 2P+N+G
110-125 volts 60 Hz ORANGE
220-250 volts 60 Hz ORANGE
208-220 volts 60 Hz BLUE
255-277 volts 60 Hz RED
440-480 volts 60 Hz RED
347-600 volts 60 Hz BLACK
Three Poles and One Ground - 3P+G
208-220 volts 60 Hz BLUE
220-250 volts 60 Hz ORANGE
440-480 volts 60 Hz RED
600 volts 60 Hz BLACK
Three Poles, One Neutral and One Ground - 3P+N+G
110-125 volts 60 Hz ORANGE
220-250 volts 60 Hz ORANGE
120-127 volts 60 Hz BLUE
208-220 volts 60 Hz BLUE
255-277 volts 60 Hz RED
440-480 volts 60 Hz RED
347-600 volts 60 Hz BLACK
Friday, March 23, 2012
Meltric DSN 30 Part numbers
Anderson-Bolds and Meltric can supply 30 amp Pin and Sleeve connectors.
Meltric DSN plugs and receptacles are also disconnect switches.
If you have a Meltric Part number and you want a quote, please go to our contact FORM HERE
Spare parts are listed below.
| 61-3A010 | DSN30 INLET INTERIOR |
| 61-3A010-B | DSN30 MALE INTERIOR BOTTOM |
| 61-3A010-T | DSN30 MALE INTERIOR TOP |
| 61-3A011 | DSN30 INLET CONTACT (W/PILOTS) |
| 61-3A011-380 | DSN30 INLET CONTACT W/O PILOTS |
| 61-3A013 | DSN30 HANDLE |
| 61-3A013-1 | DSN30 HANDLE |
| 61-3A013-114 | DSN30 HANDLE |
| 61-3A013-12 | DSN30 HANDLE |
| 61-3A013-34 | DSN30 HANDLE W/ 3/4" NPT |
| 61-3A014 | DSN30 INLET CASING |
| 61-3A020 | DSN30 RECEPTACLE INTERIOR |
| 61-3A020-B | DSN30 RECP INTERIOR BOTTOM |
| 61-3A020-T | DSN30 FEMALE INTERIOR TOP |
| 61-3A021 | DSN30 RECP CONTACT (W/PILOTS) |
| 61-3A021-380 | DSN30 RECP CONTACT W/O PILOTS |
| 61-3A023-12 | DSN30 CONDUIT BOX |
| 61-3A023-34 | DSN30 CONDUIT BOX |
| 61-3A024 | DSN30 RECEPTACLE CASING |
| 61-3A024-843 | DSN30 REC CASING W/PADLOCK PAW |
| 61-3A027 | DSN30 ANGLE, POLY |
| 61-3A053-080-1 | DSN30 ANGLE/BOX W/ 1" NPT |
| 61-3A053-080-12 | DSN30 ANGLE/BOX |
| 61-3A053-080-34 | DSN30 ANGLE/BOX |
| 61-3A126 | DSN30 INLET CAP |
| 61-3A346 | DSN30 FINGER DRAWPLATE KIT BAG |
| 61-3A826 | DSN30 LOCKING CAP |
| 61-3AB26 | DSN30 BLUE GASKET |
| 61-3AC26 | DSN30 ORANGE GASKET |
| 61-3AJ26 | DSN30 YELLOW GASKET |
| 61-3AM26 | DSN30 MARECHAL GASKET |
| 61-3AN26 | DSN30 BLACK GASKET |
| 61-3AR26 | DSN30 RED GASKET |
Plugs, Receptacles, handles and angle boxes are below.
| 63-34042 | DSN30 RECEPTACLE |
| 63-34043 | DSN30 RECEPTACLE |
| 63-34043-270 | DSN30 RECEPTACLE |
| 63-34043-270-NC | DSN30 REC W/MICROSWITCH |
| 63-34043-375 | DSN30 RECEPTACLE |
| 63-34043-843 | DSN30 RECEPTACLE |
| 63-34043-972 | DSN30 RECEPTACLE W/2 PILOTS |
| 63-34043-972-348-A188 | DSN30 REC W/2 PILOTS, 348 PAWL |
| 63-34043-972-375 | DSN30 RECEPTACLE |
| 63-34043-972-NC | DSN30 RECEPTACLE W/2 PILOTS |
| 63-34045 | DSN30 RECEPTACLE |
| 63-34047 | DSN30 RECEPTACLE |
| 63-34047-972 | DSN30 RECEPTACLE W/2 PILOTS |
| 63-34072 | DSN30 RECEPTACLE |
| 63-34072-270 | DSN30 RECEPTACLE W/MICROSWITCH |
| 63-34073 | DSN30 RECEPTACLE |
| 63-34073-NC | DSN30 RECEPTACLE |
| 63-34075 | DSN30 RECEPTACLE |
| 63-34076 | DSN30 RECEPTACLE |
| 63-34142 | DSN30 RECEPTACLE |
| 63-34143 | DSN30 RECEPTACLE |
| 63-34143-972-270 | DSN30 RECP 2PILOTS,MICROSWITCH |
| 63-34147 | DSN30 RECEPTACLE |
| 63-34162 | DSN30 RECEPTACLE |
| 63-34163 | DSN30 RECEPTACLE |
| 63-34167 | DSN30 RECEPTACLE |
| 63-34167-375 | DSN30 RECEPTACLE |
| 63-38042 | DSN30 INLET |
| 63-38043 | DSN30 INLET |
| 63-38043-338-A188 | DSN30 INLET W/ PRL AND |
| 63-38043-972 | DSN30 INLET W/2 PILOTS |
| 63-38043-972-A188 | DSN30 INLET |
| 63-38045 | DSN30 INLET |
| 63-38047 | DSN30 INLET |
| 63-38047-972 | DSN30 INLET W/2 PILOTS |
| 63-38047-NNF | DSN30 INLET |
| 63-38072 | DSN30 INLET |
| 63-38073 | DSN30 INLET |
| 63-38073-972 | DSN30 INLET W/2 PILOTS |
| 63-38075 | DSN30 INLET |
| 63-38076 | DSN30 INLET |
| 63-38076-NNF | DSN30 INLET |
| 63-38142 | DSN30 INLET |
| 63-38143 | DSN30 INLET |
| 63-38147 | DSN30 INLET |
| 63-38147-972-NNF | DSN30 INLET W/2 PILOTS |
| 63-38162 | DSN30 INLET |
| 63-38163 | DSN30 INLET |
| 63-38167 | DSN30 INLET |
Buy DSN 30 Meltric parts here!
866-360-9810
Saturday, December 17, 2011
Meltric DSN Spec

Anderson-Bolds and Meltric present the DSN series of deContactor. Safety First.
Detailed spec for MELTRIC DECONTACTOR Series Switch Rated Plugs & Receptacles
Note to specifying engineer: In order to specify Meltric DECONTACTOR Series plugs and receptacles, include one or all of the items below in your job specification. The items in bold are exclusive to Meltric Decontactors and thus should be included in the specification wherever practical to avoid substitution of pin and sleeve or twist type devices.
- Plugs and receptacles must be listed to UL Subject 2682 'Switch Rated Plugs and Receptacles.' (Alternate for Canada: Plugs and receptacles must be CSA listed to UL Subject 2682 'Switch Rated Plugs and Receptacles').
- Plugs and receptacles must have constant pressure butt-contacts with solid silver-nickel tips. Pin and sleeve contacts are not permitted.
- Receptacles must have dead front construction: live parts must be inaccessible to thin tool or wire.
- Plugs and receptacles must be able to close at least once on a conditional short-circuit current of 65,000A. (Short circuit testing should be performed with RK1 current limiting fuses sized at 400% of the highest full load motor ampacity associated with the device).
- Plugs and receptacles must incorporate an integral switching mechanism to ensure the load is broken before the plug is removed from the receptacle.
- Plug and receptacle wire terminals must be spring-assisted to prevent loosening due to conductor yielding, shocks, vibrations or thermal cycling.
- The minimum environmental rating of plugs and receptacles must be NEMA 3R (DS Series), NEMA 4X and IP 66+67 (DSN Series), or IP67 (DB Series).
- Ingress protection must be achieved automatically when the plug is fully inserted into the receptacles, without additional manual operation (except DB Series).
- Plugs and receptacles must have a system of different keying positions in order to discriminate between circuits or incompatible operating voltages or frequencies.
- Plugs and receptacles installed outdoor must be able to withstand UV radiation.
- Plugs and receptacles shall be Meltric Decontactor Series or equal.
866-360-9810