Showing posts with label 20 amp. Show all posts
Showing posts with label 20 amp. Show all posts

Monday, August 31, 2015

Carlo Gavazzi RGC Din Rail Solid State Relays


Anderson-Bolds supplies DIN rail mount SSR's by Carlo Gavazzi

Carlo Gavazzi offers a comprehensive range of solid state relays (SSR’s) featuring direct copper bonding technology for increased life and reliability. SSR’s are used extensively in the plastics, packaging, food processing, and HVAC industries - primarily for temperature control. They are the logical replacement for mercury contractors.

Other applications include lighting and pump switching. Furthermore, many of our solid state relays feature horsepower ratings making them suitable for controlling motorized dampers in HVAC control systems - where their long life and noise-free switching make them ideal replacements for mechanical contractors.

Carlo Gavazzi's solid state relays range includes single phase relays up to 125 amps and 3 phase relays up to 75 amps. They are available with both digital and analogue inputs (4-20 mA or 0-10 V) Furthermore, we also offer a complete range of SSR's with a built-in heat sink.


This new range of solid state contactors presents a unique opportunity to maximize efficiency in panel space and is an evolution of solid state switches for which Carlo Gavazzi is very well known.  The Nominal current ratings are at 40 ̊C. The smallest width is 17.5mm and is rated at 20 AAC. Power and control terminals allow for safe looping of cables. Voltage transient protection is standard across the output with a varistor. Specifications are stated at 25°C unless otherwise noted. 
 
  
The new platform of RG Series also features wire bonding technology, which is a fully automated process resulting in more reliable connections, but more importantly it reduces thermal stress, therefore providing the RG Series with two to three times longer lifetime than our older designs and those by our competitors, which typically have solder connections.  The RG Series is cUL and VDE approved, and also CE certified. 



Some other dynamic features of these new game-changing products include:

Integral heat sink with robust metal DIN rail adapters

UL certified motor ratings at 600VAC

UL SCCR rating of 100kA with J class (or equivalent) fuses

Amperage rating based upon 40°C ambient temperature

Integrated MOV for over voltage protection

Integrated cooling fan on higher amperage models

High I2t of up to 18,000 A2s on some types

Option for screw, box clamp or spring loaded control inputs on some types

Optional monitoring of SSR and load failures on some types


Optional EMR and transistor alarm outputs on some types


The Carlo Gavazzi RGC can be ordered in either contactor terminal orientation of SSR orientation. The E version is contactor style and the U version and the SSR style.  Amp ratings are 15, 20, 25, 30, 40, 42, 60, 62, 90 and 02.  Normally SSR's are sized up t 80% of their rating and should be derated when exposed to high ambient temperatures.

Below are a varied assortment of the relays with links to our web site.
Click here for all the Carlo Gavazzi RGC SSR's (Solid State Relays).

RGC1A23D15KKE
Carlo Gavazzi RGC SSR, 20 amps, 20-275 volts, 3-32 vdc, 17.5 mm

RGC1A23D20MKE
Carlo Gavazzi RGC SSR, 23 amps, 20-275 volts, 3-32 vdc, 17.5 mm

RGC1A23D30KKE
Carlo Gavazzi RGC SSR, 30 amps, 20-275 volts, 3-32 vdc, 22.5 mm

RGC1A23A40KGE
Carlo Gavazzi RGC SSR, 40 amps, 20-275 volts, 20-275 vac, 35.6 mm

RGC1A23D60KGE
Carlo Gavazzi RGC SSR, 60 amps, 20-275 volts, 3-32 vdc, 69.1 mm

RGC1A23A62KGE
Carlo Gavazzi RGC SSR, 65 amps, 20-275 volts, 20-275 vac, 69.1 mm

RGC1A60D40KGU
Carlo Gavazzi RGC SSR, 40 amps, 42-600 volts, 3-32 vdc, 35.6 mm

RGC1A60A42KGU
Carlo Gavazzi RGC SSR, 43 amps, 42-600 volts, 20-275 vac, 35.6 mm

RGC1A60D60KGU
Carlo Gavazzi RGC SSR, 60 amps, 42-600 volts, 3-32 vdc, 69.1 mm

RGC1A60A62KGU
Carlo Gavazzi RGC SSR, 65 amps, 42-600 volts, 20-275 vac, 69.1 mm

RGC1A23D90GGUP
Carlo Gavazzi RGC SSR, 85 amps, 20-275 volts, 3-32 vdc, 69.1 mm

RGC1A60D90GGUP
Carlo Gavazzi RGC SSR, 85 amps, 42-600 volts, 3-32 vdc, 69.1 mm

RGC1A60A90GGUP
Carlo Gavazzi RGC SSR, 85 amps, 42-600 volts, 20-275 vac, 69.1 mm

Call for application help for your industrial heating application.  We can provide heaters, sensors and switches.  Contact us here!

Saturday, December 17, 2011

Meltric DSN Spec


Anderson-Bolds and Meltric present the DSN series of deContactor. Safety First.

Detailed spec for MELTRIC DECONTACTOR Series Switch Rated Plugs & Receptacles

Note to specifying engineer: In order to specify Meltric DECONTACTOR Series plugs and receptacles, include one or all of the items below in your job specification. The items in bold are exclusive to Meltric Decontactors and thus should be included in the specification wherever practical to avoid substitution of pin and sleeve or twist type devices.

  1. Plugs and receptacles must be listed to UL Subject 2682 'Switch Rated Plugs and Receptacles.' (Alternate for Canada: Plugs and receptacles must be CSA listed to UL Subject 2682 'Switch Rated Plugs and Receptacles').
  2. Plugs and receptacles must have constant pressure butt-contacts with solid silver-nickel tips. Pin and sleeve contacts are not permitted.
  3. Receptacles must have dead front construction: live parts must be inaccessible to thin tool or wire.
  4. Plugs and receptacles must be able to close at least once on a conditional short-circuit current of 65,000A. (Short circuit testing should be performed with RK1 current limiting fuses sized at 400% of the highest full load motor ampacity associated with the device).
  5. Plugs and receptacles must incorporate an integral switching mechanism to ensure the load is broken before the plug is removed from the receptacle.
  6. Plug and receptacle wire terminals must be spring-assisted to prevent loosening due to conductor yielding, shocks, vibrations or thermal cycling.
  7. The minimum environmental rating of plugs and receptacles must be NEMA 3R (DS Series), NEMA 4X and IP 66+67 (DSN Series), or IP67 (DB Series).
  8. Ingress protection must be achieved automatically when the plug is fully inserted into the receptacles, without additional manual operation (except DB Series).
  9. Plugs and receptacles must have a system of different keying positions in order to discriminate between circuits or incompatible operating voltages or frequencies.
  10. Plugs and receptacles installed outdoor must be able to withstand UV radiation.
  11. Plugs and receptacles shall be Meltric Decontactor Series or equal.


866-360-9810