Sunday, July 31, 2016

Carlo Gavazzi IP 69K PD30ET Photo Electric Sensors

Anderson-Bolds Sells the IP69 Stainless Steel Sensors from Carlo Gavazzi

July 2016 – CARLO GAVAZZI is proud to announce the launch of their new series of IP69K stainless steel photoelectric sensors, the PD30ET Series.
The new PD30ET Series complements the already popular PD30 photoelectric sensors, with robust AISI316L stainless steel housings. With an IP69K environmental rating and ECOLAB certification, reliable operation is ensured even in the harshest of environments. The PD30ETprovides outstanding resistance to high-pressure wash-down, aggressive cleaning agents, harsh disinfectants and high temperatures frequently found in the Food & Beverage industry. The PD30ET is also ideal for other harsh environments, including Material Handling, Packaging, Agriculture, and Mobile Equipment.

Main features of the PD30ET Series include:
Industry standard dimensions:
  - Housing: 11 x 21 x 31.5mm
  - Mounting: 25.4mm spacing, (2) M3 holes
AISI 316L stainless steel housing
NO and NC outputs, NPN or PNP versions
10–30VDC power supply
IP67, IP68 and IP69K ratings
cULus, ECOLAB, and CE approved
Top potentiometer set-up
Connections: 4-pin M8 plug or 2m cable
The PD30ET Series includes the following sensing types:
Diffuse reflective:
  - Extremely wide-angled (up to 200mm)
  - Long range (up to 1m)
Background Suppression, Active Pixel Sensor:
  - Visible red light version (up to 200mm)
  - Infrared version (up to 200mm)
Retro-Reflective:
  - Polarized visible red light (up to 6m)
  - Non-polarized infrared (up to 6m)
Through-beam versions (up to 15m)



Anderson-Bolds
216-360-9800
www.anderson-bolds.com


Saturday, June 25, 2016

Jefferson ZERO Minimum Pressure Valves

Anderson-Bolds sells ZERO min pressure differential valves by Jefferson

Click here to View the Jefferson 1314 Series ZERO Minimum Valves

The Jefferson 1314 Series valves in sizes from 3/4 inch NPT to 3 inch NPT are designed to be very rugged and to be used in industrial applications. The hung piston valves require no differential pressure to close or open and the Normally Closed valves will remain open until de-energized.  This is a trait need to drain large tanks, like fuel or gasoline tanks.  Paired with a NEMA 7 housing makes these valves the perfect choice for oil and gasoline tank yards.













Applications:
•Large Tank Draining
•Pumps of re-circulation for cold or hot water. 
•Heating with low or high pressure steam.
•Laundry equipments.
•Spraying. Irrigation. Dishwashers.
•Air dryers. water treatment. Vacuum systems 


Main characteristics:


Normally closed.
Pilot operated.
Bronze, stainless steel body.
BSP or NPT threaded connection.
Brass, stainless steel piston, among others.
Coil: Encapsulated up to 150 °C (302 °F) and coated with glass fibre and insulating impregnation up to 180 °C (356 °F), (for steam).

Interconnection cables. Internal general use housing. 3/4 ” NF electric connection.
Core: 430 F s.s.


Options:
•Explosion and / or weather proof housing. 
•Manual operator on the main orifice. 
•Flanged connections. 



2 inch valve with flange connections















Jefferson Brass Solenoid Valve Z1314BV06AT
120/60, 3/4 Inch NPT, NEMA 4/7, 0 PSI min, 105 max, N.C., Viton Seals

Jefferson Stainless Solenoid Valve Z1314SV06AT
120/60, 3/4 Inch NPT, NEMA 4/7, 0 PSI min, 105 max, N.C., Viton Seals

Jefferson Stainless Solenoid Valve Z1314SV08AT, 120/60
1 Inch NPT, NEMA 4/7, 0 PSI min, 105 max, N.C., Viton Seals

Jefferson Stainless Solenoid Valve Z1314SV12AT
120/60, 1-1/2 Inch NPT, NEMA 4/7, 0 PSI Min, 105 max, N.C., Viton Seals

Jefferson Brass Solenoid Valve Z1314BV12AT
120/60, 1-1/2 Inch NPT, NEMA 4/7, 0 PSI min, 105 max, N.C., Viton Seals

Jefferson Brass Solenoid Valve Z1314BV16AT
120/60, 2 Inch NPT, NEMA 4/7, 0 PSI min, 105 max, N.C., Viton Seals

Jefferson Stainless Solenoid Valve Z1314SV16AT
120/60, 2 Inch NPT, NEMA 4/7, 0 PSI min, 105 max, N.C., Viton Seals

Z6214BLVGA Bronze Jefferson Valve
120/60, 3 Inch NPT, NEMA 4/7, 0 PSI min, 105 max, N.C., Viton Seals

Z6214SLVGA Stainless Steel Jefferson Valve
120/60, 3 Inch NPT, NEMA 4/7, 0 PSI min, 105 max, N.C.


Valves can come with other voltages as well.  24vdc, 240 vac, 24 VAC, 480 vac

Click HERE to contact Anderson-Bolds


www.anderson-bolds.com
216-360-9800


Tuesday, May 31, 2016

Barksdale Explosion Proof Pressure Switches D1X and D2X Series

Explosion Proof Diaphragm Pressure Switches from Barksdale and Anderson-Bolds

Contact Anderson-Bolds : Click HERE.

Barksdale, a World leader in Pressure switch design and manufacture, has updated their diaphragm series pressure switches with ATEX approvals for hazardous locations and environments. The Barksdale series D1X and D2X (single and dual set) switches are the industry standard for mechanical diaphragm pressure switches.  Barksdale D1X and D2X switches can be found used for pump and compressor monitoring, hydraulic units, the oil and gas industry, food and beverage, utility and power generation and in the mining industry as well as general industry where hazardous areas are present.

The features of the Barkdale D1X and D2X pressure switches are: hermetically sealed, Tamper Proof Adjustment, pressure or vacuum applications, UL, CSA and ATEX approved and NEMA 4, 7, 9 and IP66 housing.












Specifications:
Accuracy: ± 0.5% of the adjustable range
Switch Rating: 10 Amps @ 125/250 VAC; 3 amps @ 480 VAC (Class A or H Limit Switch)
Wetted Parts: Stainless Steel process fitting and diaphragm and die cast aluminum enclosure.
Electrical Connections: Screw Terminals via conduit connection.
Pressure Connection is 1/4 inch NPT female (1/2 inch optional)
Enclosure Rating: NEMA 4, 7 & 9
Approvals: All models are UL and CSA listed for hazardous locations Class 1, Groups B,C,D and Class 2, Groups E, F, & G.  UL file # E37043.  CSA file is LR22354.
ATEX markings:
 EX models are ATEX marked as follows:
 0081, ISSeP 08 ATEX024X
 II 2G D, Ex d IIC T6
 Ex tD A21 IP66 T80°C

-40°C ≤ Tamb ≤ +75°C
Temperature Range is -40° to +165°F (-40° to +75°C)
Pressure Range: 0 to 150 PSI depending on model number.

Barksdale UL/CSA Listed Explosion-Proof Pressure Switch, D1XA3SS-UL, 1/4 inch SS NPT, .03 - 3.00 PSI

Barksdale UL/CSA Explosion-Proof Pressure Switch, D2XA3SS-UL, Dual Set, 1/4 inch SS NPT, .03 - 3.00 PSI

Barksdale UL/CSA  Explosion-Proof Pressure Switch, D1XH18SS-UL, 1/4 inch SS NPT, .40 - 18.00 PSI

Barksdale UL/CSA  Explosion-Proof Pressure Switch, D2XH18SS-UL, Dual Set, 1/4 inch SS NPT, .40 - 18.00 PSI

Barksdale UL/CSA  Explosion-Proof Pressure Switch, D1XA80SS-UL, 1/4 inch SS NPT, .50 - 80.00 PSI

Barksdale UL/CSA  Explosion-Proof Pressure Switch, D2XA80SS-UL, Dual Set 1/4 inch SS NPT, .50 - 80.00 PSI

Barksdale UL/CSA  Explosion-Proof Pressure Switch, D1XH150SS-UL, 1/4 inch SS NPT, 1.50 - 150.00 PSI

Barksdale UL/CSA  Explosion-Proof Pressure Switch, D2XH150SS-UL, Dual Set, 1/4 inch SS NPT, 1.50 - 150.0 PSI



www.anderson-bolds.com
216-360-9800


Saturday, April 30, 2016

TRC Southwire High Power 100 Amp GFCI - ELCI

Anderson-Bolds sells TRC / Southwire GFCI's and ELCI's up to 100 AMPS.

These are the  new Southwire TRC 24736-001 and 24994-001 100 amp 6-10-30 Trip Level GFCI and ELCI Units.

Anderson-Bolds is your source for Commercial safety products including GFCIs and ELCIs.

GFCIs and ELCIs are used for personnel and equipment protection.


TRC has engineered a new option for the HD-PROTM series called 6.10.30TM.
Configured for both in-line and bulk head mount. This unique new design allows the user to select and lock in the most sensitive trip level at which a specific type of equipment can be operated without nuisance tripping. Adjustable settings
include trip levels for 6mA, 10mA and 30mA. Trip level flexibility to meet your needs in one single device - HD-PROTM with 6.10.30TM.  6.10.30TM key enables trip level selection and locking at a trip level with key removal.  

The GFCIs protect Motors, Pumps, Pressure Washers, Conveyors, Welders and lifts.

Go To GFCI/ELCI Store Page HERE. or call 216-360-9800


TRC 24736-001 and TRC 24994-001
100 amp GFCI/ELCI





















Specifications:

Voltage:  480 or 600 volts AC and three phase
AMPS: 100
Cord Gauge: 2/4 AWG
Trip Levels: 6mA, 10mA, 30mA - chosen by Key Switch
GFCI Response Time: 25mS
Frequency: 50/60 Hz
Endurance: 3,000 operations minimum
Overload Current: SIX times rated current
Temperature Range: -20C to +40C
Power n Indicator: Light
Drop Out Voltage: About 60% rated voltage
Reset Type: Auto
Connection: Flying Leads
Enclosure: NEMA 4 Polymer



216-360-9800
www.anderson-bolds.com





Friday, April 29, 2016

ATC 17.5 mm Din Rail Timer 175MD


Anderson-Bolds sells the ATC 175MD Din Rail Timer


 The new Automatic Timing and Controls 175MD din rail mount multi-function timer series provides slim space saving design and 15 functions including on-delay, interval, signal off delay and asymmetrical repeat cycle. 
Packaged in a 17.5 mm housing with an 8 amp SPDT relay output contact configuration it can be easily configured via front keypad buttons with backlit display for time range (0 to 999 seconds / minutes / hours), time scale and mode setting and includes a universal supply voltage of 20-240 vac/dc (50/60Hz). 

The ATC 175MD is UL approved and CE certified. 


The ATC 175MD Features:
15 Functions
8 time ranges
Front Key Pad Setting
Universal Supply Voltage
Slim Design
DIN rail Mount
Size is 17.5 millimeters


ATC 175MD Din Rail Timer Anderson-Bolds

























Specifications:

Supply Voltage: 20-240 AC/DC and 50/60 Hz.
IP40 for case and IP20 for terminals
Contacts: SPDT 8 amps @ 250V AC
Time Ranges: 0-99.9 Seconds, 0-99.9 Minutes, 0-99.9 Hours, 0-999 Seconds, 0-999 Minutes, 0-999 Hours, 0-9:59 min:secs (10 minutes), 0-9:59 hr:min (10 hours)
Counting/Timing direction is DOWN.
Memory : YES

Modes:
ON Delay or Delay on Make (A)
Interval (B)
Asymmetrical cyclic (OFF time first) (C)   FLIP FLOP Timer
Asymmetrical cyclic (ON time first) (D)     FLIP FLOP Timer
Cyclic (OFF time first) (E)   Recycle Timer
Cyclic (ON time first) (F)     Recycle Timer
Pulse Output (H)
OFF Delay or Delay on Break (J)
Delay on Make / Break (K)
Interval after Break (L)
Single Shot (P)
Retriggerable Single Shot (Q)
Latching Relay (R)
Delay with Totalize (T)
Interval with Totalize (U)

Dimensions:
17.5 width x 90 high x 44 deep (mm)

UL Approved and CE certified

216-360-9800

Sunday, April 3, 2016

Fenwal 17000-0 Sereis THERMOSWITCHES

Anderson-Bolds Stocks Fenwal 17000-0 series Temperature switches.

NOTE: The Fenwal Brass THERMOSWITCHES have been discontinued.
The Replacement Stainless Steel Switches are still available.
Besides being Stainless Steel the switches have a temperature range of -100 to 600ºF.
The Brass switches went up to 400ºF. 
All other aspects are identical.

The Fenwal THERMOSWITCH developed by Dr. Wall and Mr. Fenn in the 1930's is still used to day for accurate Temperature control for commercial and industrial applications.  The THERMOSWITCH used the method of dis-similar metals to measure temperature. The outer shell and interior struts expand and contract at different rates and by use of a spring the switch can be adjusted to require more or less expansion for different temperature settings.

The Fenwal Series 17000-0 is a simple cartridge style thermostat, 5/8 inch in diameter and 3.72 inches long.
It is made of brass or stainless steel, the brass version has a range of -100 to 400F  and the Stainless Steel has a range of -100 to 600F.

The Fenwal 17000-0 series also has  the following versions:

Fenwal HEX Head style with a Hex nut and 1/2 inch NPT pipe thread mounting. 17100-0
The Stainless Version is 17102-0.

The Fenwal Block Head style for adding certain Modifications.  17200-0
The Stainless Version is 17202-0.

The Flange Mount with Block head for easy mounting.  17300-0
The Stainless Version is 17302-0.

The Fenwal 17800-0 with terminal box, NPT threads and knob and dial. 
The Stainless Version is 17802-0.

The Fenwal 18000-0 series with double headed fittings (coupling head).
The Stainless Version is 18002-0.

All the above versions come in a stainless steel versions as well as open-on-temperature rise or close-on-temperature rise versions.

Anderson-Bolds
216-360-9800


Wednesday, February 10, 2016

Process Ovens Over 40 years Old


Safety Updates for Older Ovens.

 

Most Process ovens made over 40 years ago did not include an excess temperature controller or separate heating element contactors to protect the oven from overheating if the main temperature controller or contactors fail. 
 Any ovens like this should not be used until this safety equipment is installed.  Failure to install this safety equipment could result in the oven overheating and a fire that could result in oven damage, loss of the product load, building damage and injury to personnel.
 

A field kit to add the excess temperature controller and separate contractors should be ordered from the MFG.

The excess temperature controller and separate contactors are now standard equipment on all Grieve ovens.  Also standard is a recirculating blower airflow safety switch to shut down the oven heat if the recirculating blower fails.  This is a pressure differential switch that senses the pressure created when the blower wheel is turning.  This switch protects the oven heating elements by preventing them from heating when air is not being recirculated over them.  A field kit for installation of the recirculating blower airflow safety switch should be purchased from the oven MFG.


When installing new safety equipment it can be a good idea to add other new electronics to the oven for better performance.  New electronics could be a digital temperature controller, programmable digital temperature controller, new thermocouples or a digital timer.  Grieve can provide a field kit to add a digital temperature controllers as well as and a field kit for a digital shut down timer. For electric Ovens new elements can be ordered as well along with pin and sleeve disconnect switches for added electrical safety for personnel. We can provide Gas meters for gas ovens to measure gas flow at the oven and shut the oven down in a dangerous situation.

Grieve's field kits include installation instructions, wiring diagram showing items to be removed, wiring diagram showing items to be added and revised wiring diagram for your records.  Our kits will be based on how the ovens were constructed when they left our factory.  If there have been changes made to the oven in the field they will not be included in our revised wiring diagram.   


Grieve will provide all parts except for standard wire, conduit and conduit fittings.  These items are better provided in the field as necessary to connect the components being added.  Conduit would only be required for the air flow safety switch as the other items are mounted in the oven control panel.

Please contact Anderson-Bolds with the oven serial number, job # and model number all of which can be found on the name plate of the oven.  We can also provide new wiring schematics for old ovens and instruction manuals.  Grieve and Anderson-Bolds want our products to be operated in the safest manner possible. 


Contact Anderson-Bolds at:
216-360-9800 
grieve@anderson-bolds.com